									| 土木工程 |  |     |  |  
    					|  |  
    					| 内廊式建筑火灾外部烟气蔓延规律 |  
						| 张晓涛1,2(  ),陆愈实2,*(  ),陆凯华2 |  
					| 1. 湖北商贸学院 建筑经济与工程管理学院,湖北 武汉 430079 2. 中国地质大学 工程学院,湖北 武汉 430074
 |  
						|  |  
    					| Spreading characteristics of external smoke for buildings with internal corridor |  
						| Xiao-tao ZHANG1,2(  ),Yu-shi LU2,*(  ),Kai-hua LU2 |  
						| 1. School of Architectural Economics and Engineering Management, Hubei Business College, Wuhan 430079, China 2. Faculty of Engineering, China University of Geosciences, Wuhan 430074, China
 |  
					
						| 
								
									|  
          
          
            
             
			              
            
									            
									                
																																															
																| 1 | 秦霜霜, 吕伟, 余惠琴, 等 基于案例推理的火灾事故相似度及应对措施研究[J]. 安全与环境工程, 2018, 25 (5): 150- 155 QIN Shuang-shuang, LV Wei, YU Hui-qin, et al Similarity and countermeasure of fire accident based on case-based reasoning[J]. Safety and Environmental Engineering, 2018, 25 (5): 150- 155
 |  
																| 2 | LUO N, LI A, GAO R, et al An experiment and simulation of smoke confinement utilizing an air curtain[J]. Safety Science, 2013, 59: 10- 18 doi: 10.1016/j.ssci.2013.04.009
 |  
																| 3 | LI S C, HUANG D F, MENG N, et al Smoke spread velocity along a corridor induced by an adjacent compartment fire with outdoor wind[J]. Applied Thermal Engineering, 2017, 111: 420- 430 doi: 10.1016/j.applthermaleng.2016.09.086
 |  
																| 4 | LI M, GAO Z, JI J, et al Modeling of positive pressure ventilation to prevent smoke spreading in sprinklered high-rise buildings[J]. Fire Safety Journal, 2018, 95: 87- 100 doi: 10.1016/j.firesaf.2017.11.004
 |  
																| 5 | HUANG D F, LI S C An experimental investigation of stratification characteristic of fire smoke in the corridor under the effect of outdoor wind[J]. Journal of Wind Engineering and Industrial Aerodynamics, 2018, 179: 173- 183 doi: 10.1016/j.jweia.2018.05.021
 |  
																| 6 | CHEN Y, YANG L, FU Z, et al Gas flow behavior and flow transition in elevator shafts considering elevator motion during a building fire[J]. Building Simulation, 2018, 11 (4): 765- 771 doi: 10.1007/s12273-018-0430-3
 |  
																| 7 | CHEN Y, CHEN J, FU Z, et al Gas characteristics and effectiveness of smoke control systems in elevator lobbies during elevator evacuation in a high-rise building fire[J]. Combustion Science and Technology, 2018, 190 (8): 1- 14 |  
																| 8 | ZHAO W, ZONG R, FAN X, et al Impact of openings on fire properties in the confined corridors[J]. Applied Thermal Engineering, 2017, 110: 746- 757 doi: 10.1016/j.applthermaleng.2016.08.206
 |  
																| 9 | 张晓涛, 谭翀, 陆愈实 传统控烟设施对空气幕阻烟性能的影响[J]. 浙江大学学报: 工学版, 2016, 50 (9): 1738- 1745 ZHANG Xiao-tao, TAN Chong, LU Yu-shi Influence of traditional smoke control facilities on smoke confinement performance of air curtain[J]. Journal of Zhejiang University: Engineering Science, 2016, 50 (9): 1738- 1745
 |  
																| 10 | 张晓涛, 吕奎, 陆愈实 冷热气体介质对空气幕阻隔作用的影响[J]. 哈尔滨工程大学学报, 2016, 37 (12): 1677- 1684 ZHANG Xiao-tao, LV Kui, LU Yu-shi Influence of normal and high temperatures on the obstruction efficiency of air curtains[J]. Journal of Harbin Engineering University, 2016, 37 (12): 1677- 1684
 |  
																| 11 | 茅靳丰, 余南田, 周进, 等 机械排烟量对防护工程走廊烟气扩散的影响[J]. 工程热物理学报, 2018, 39 (07): 1614- 1620 MAO Jin-feng, YU Nan-tian, ZHOU Jin, et al Effect of mechanical exhaust smoke volume on smoke diffusion in protective engineering corridor[J]. Journal of Engineering Thermophysics, 2018, 39 (07): 1614- 1620
 |  
																| 12 | MCGRATTAN K, FORNEY G. Fire dynamics simulator user’s guide [M]. Gaithersburg: NIST, 2013. |  
																| 13 | WU Y, LI A, MA J, et al Numerical studies on smoke natural filling in an underground passage with validation by reduced-scale experiments[J]. Nature Environment and Pollution Technology, 2013, 12 (1): 35- 42 |  
																| 14 | YU L, BEJI T, LIU F, et al Analysis of FDS 6 simulation results for planar air curtain related flows from straight rectangular ducts[J]. Fire Technology, 2018, 54 (2): 419- 435 doi: 10.1007/s10694-017-0690-y
 |  
																| 15 | 潘燕红. 高层建筑消防安全疏散现状问题与对策研究[D]. 广州: 华南理工大学, 2013. PAN Yan-hong. The high-rise building fire safety evacuation problems and countermeasures [D]. Guangzhou: South China University of Technology, 2013.
 |  
																| 16 | 张培红,王增欣. 建筑消防[M]. 北京: 机械工业出版社, 2008. |  
																| 17 | ZHANG W, HAMER A, KLASSEN M, et al Turbulence statistics in a fire room model by large eddy simulation[J]. Fire Safety Journal, 2002, 37: 721 doi: 10.1016/S0379-7112(02)00030-9
 |  
																| 18 | JI J, YUAN X, LI K, et al Influence of the external wind on flame shapes of n-heptane pool fires in long passage connected to a shaft[J]. Combustion and Flame, 2015, 162 (5): 2098- 2107 doi: 10.1016/j.combustflame.2015.01.008
 |  
             
												
											    	
											        	|  | Viewed |  
											        	|  |  |  
												        |  | Full text 
 | 
 
 |  
												        |  |  |  
												        |  | Abstract 
 | 
 |  
												        |  |  |  
												        |  | Cited |  |  
												        |  |  |  |  
													    |  | Shared |  |  
													    |  |  |  |  
													    |  | Discussed |  |  |  |  |