Please wait a minute...
JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE)
Mechanical and Energy Engineering     
Influence of solution heat exchangers on double absorption heat transformer (DAHT)
LI Hua-shan, WANG Han-zhi, WANG Ling-bao, WANG Xian-long, BU Xian-biao
1. Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510640, China;
2. Key Laboratory of Renewable Energy, Chinese Academy of Sciences, Guangzhou 510640, China;
3. Guangdong Key Laboratory of New and Renewable Energy Research and Development, Guangzhou 510640, China;
4. University of Chinese Academy of Sciences, Beijing 100049, China
Download:   PDF(1120KB) HTML
Export: BibTeX | EndNote (RIS)      

Abstract  
A mathematical model was established for the double absorption heat transformer (DAHT)with wider range in which the system can maintain high thermodynamic performance. With engineering equation solver (EES), the influence of solution heat exchangers on the coefficient of performance, second law efficiency, total heat transfer area and the technical economy of DAHT system was investigated. Results show that the solution heat exchangers have significant impact on the DAHT system performance; compared with the solution heat exchanger between the generator and absorber/evaporator, the impact of the one that between the generator and absorber is more prominent. As the effectiveness of the solution heat exchangers increases, the coefficient of performance and second law efficiency of the DAHT system increase, but the system total heat transfer area first decreases and then increases. Taking technical economy into account, the solution heat exchangers should be optimized according to the specific working conditions in the design of the DAHT system.


Published: 01 March 2017
CLC:  TK 123  
Cite this article:

LI Hua-shan, WANG Han-zhi, WANG Ling-bao, WANG Xian-long, BU Xian-biao. Influence of solution heat exchangers on double absorption heat transformer (DAHT). JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2017, 51(3): 471-477.


溶液热交换器对双吸收式热变换器性能的影响

针对一种具有较高热力性能且工况范围较宽的双吸收式热变换器(DAHT)系统建立数学模型.利用EES软件对系统进行计算模拟,分析溶液热交换器对DAHT系统的性能系数、第二定律效率、总传热面积以及技术经济性的影响.结果表明,溶液热交换器对DAHT系统性能具有重要影响,其中发生器与吸收器之间的溶液热交换器对DAHT系统的影响较发生器和吸收/蒸发器之间的溶液热交换器对DHHT系统的影响更为显著.随着溶液热交换器效能的升高,DAHT系统的性能系数与第二定律效率均逐步升高,总传热面积却呈先减小后增加的趋势.出于技术经济性考虑,工程设计中应根据实际工况对DAHT系统的溶液热交换器进行优化.

[1] 隋军,刘锋,郭培军,等.低品位余热回收的立式降膜吸收式热变换器研究[J].制冷技术, 2015, 35(2): 8-12.
SUI Jun, LIU Feng, GUO Pei-jun, et al. Study on vertical falling film absorption heat transformer for low grade waste heat recovery [J]. Chinese Journal of Refrigeration Technology, 2015, 35(2): 8-12.
[2] RIVERA W, BEST R, CARDOSO MJ, et al. A review of absorption heat transformers [J]. Applied Thermal Engineering, 2015, 91: 654-670.
[3] 马庸颇.LiBr-H2O双吸收热变换器热力过程的模拟与优化[D].大连:大连理工大学,2004.
MA Yong-po. The simulation and optimization of the thermodynamic proeess of the LiBr-H2O double absorption heat transformer [D]. Dalian: Dalian University of Technology, 2004.
[4] FARTAJ S A. Comparison of energy, exergy, and entropy balance methods for analyzing double-stage absorption heat transformer cycles [J].
International Journal of Energy Research, 2004, 28(14): 1219-1230.
[5] ZHAO Z C, ZHANG X D, MA X H. Thermodynamic performance of a double-effect absorption heat transformer using TFE/E181 as the working fluid [J]. Applied Energy, 2005, 82(2):107-116.
[6] 尹娟,史琳,朱明善,等.二次提升型吸收式变热器热力性能分析[J].清华大学学报:自然科学版, 2000, 40(10): 88-91.
YIN Juan, SHI Lin, ZHU Ming-shan, et al. Performance analysis of the two stage heat transformer [J]. Journal of Tsinghua University: Science and Technology, 2000, 40(10): 88-91.
[7] 马学虎,李达,郝兆龙,等.高温双再生器型吸收式热变换器热力循环分析[J].大连理工大学学报,2012,52(6): 794-798.
MA Xue-hu, LI Da, HAO Zhao-long, et al. Analysis of thermodynamic cycle for double effect absorption heat transformer with high temperature [J]. Journal of Dalian University of Technology, 2012, 52(6): 794-798.
[8] CIAMBELLI P, TUFANO V. On the performance of advanced absorption heat transformers II: the double absorption configuration [J]. Heat Recovery Systems and CHP, 1988, 8(5): 451-457.
[9] 尹娟,史琳,王鑫,等.双效吸收式变热器热力性能分析[J].流体机械,2000,28(8): 50-53.
YIN Juan, SHI Lin, WANG Xin, et al. Performanceanalysis of the two stage heat transformer [J]. Fluid Machinery, 2000, 28(8): 5053.
[10] 张晓冬,李健丰.具有新的溶液循环双吸收式热变换器分析[J].大连理工大学学报,2007, 47(3): 333-337.
ZHANG Xiao-dong, LI Jian-feng. Exergy analysis of double absorption heat transformers with a new solution cycle [J]. Journal of Dalian University of Technology, 2007, 47(3): 333-337.
[11] ZHAO Z C, MA Y P, CHEN J B. Thermodynamic performance of a new type of double absorption heat transformer [J]. Applied Thermal Engineering, 2003, 23(18): 2407-2414.
[12] MARTINEZ H, RIVERA W. Energy and exergy analysis of a double absorption heat transformer operating with water/lithium bromide [J]. International Journal of Energy Research, 2009, 33(7): 662-674.
[13] 郝兆龙,马学虎,兰忠,等.高温LiBr双吸收式热变换器分析[J].大连理工大学学报,2013, 53(3): 327332.
HAO Zhao-long, MA Xue-hu, LAN Zhong, et al. Exergy analysis of a high temperature water-lithium bromide double effect absorption heat transformer [J]. Journal of Dalian University of Technology, 2013,53(3): 327-332.
[14] 赵宗昌,周方伟,李凇平.TFE-E181双吸收热变换器热力过程分析[J].大连理工大学学报,2003, 43(5):604-608.
ZHAO Zong-chang, ZHOU Fang-wei, LI Songping. Analysis of thermodynamic performance of double absorption heat transformer using TFE-E181 as working fluids [J]. Journal of Dalian University of Technology, 2003, 43(5): 604-608.
[15] REYES R M B, GOMEZ V M A, GARCIA GUTIERREZ A. Performance modelling of single and double absorption heat transformers [J]. Current Applied Physics, 2010, 10(2): S244-S248.
[16] ROMERO R J, MARTINEZ A R, SILVA S, et al. Comparison of double stage heat transformer with double absorption heat transformer operating with Carrol-Water for industrial waste heat recovery [J]. Chemical Engineering Transactions, 2011, 25: 129-134.
[17] ROMERO R J, MARTINEZ A R, SOTELO S S, et al. Advanced inverse heat pump using Carrol-Water [J]. American Journal of Environmental Engineering, 2014, 4(4A): 19-29.
[18] RIVERA W, CEREZO J, RIVERO R, et al. Single stage and double absorption heat transformers used to recover energy in a distillation column of butane and pentane [J]. International Journal of Energy Research, 2003, 27(14): 1279-1292.
[19] KHAMOOSHI M, PARHAM K, ROOZBEH I, et al. Applications of innovative configurations of double absorption heat transformers in water purification technology [J]. Desalination and Water Treatment, 2015, 57(18): 1-13.
[20] ZHAO Z C, ZHOU F W, ZHANG X D, et al. The thermodynamic performance of a new solution cycle in double absorption heat transformer using water/lithium bromide as the working fluids [J]. International Journal of Refrigeration, 2003, 26(3): 315-320.
[21] 王建国,马学虎,林海涛,等.以溴化锂溶液为工质的吸收式热转换器热力学分析[J].大连理工大学学报,2004, 44(3): 366-370.
WANG Jian-guo, MA Xue-hu, LIN Hai-tao, et al. Thermodynamic analysis for LiBr-H2O absorption heat transformer [J]. Journal of Dalian University of Technology, 2004, 44(3): 366-370.
[22] 钟理,赵文英,谭盈科.溶液换热器传热效率对高温吸收式热泵性能的影响[J].制冷,2001, 20(2): 10-15.
ZHONG Li, ZHAO Wen-ying, TAN Ying-ke. Influence of solution heat exchanger effectiveness on performance of high temperature absorption heat pumps [J]. Refrigeration, 2001, 20(2): 10-15.
[23] 戴永庆.溴化锂吸收式制冷技术及应用[M].北京:机械工业出版社,1996: 23-24.
[24] 董海虹.低温热源驱动第二类吸收式热泵的模拟优化研究[D].天津:天津大学,2006.
DONG Hai-hong.Optimization design and simulation research on the absorption heat transformer of recovering the low temperature waste heat [D].Tianjin: TianjinUniversity, 2006.
[25] PATEK J, KLOMFAR J. A computationally effective formulation of the thermodynamic properties of LiBr-H2O solutions from 273 to 500 K over full composition range [J]. International Journal of Refrigeration, 2006, 29(4): 566-578.
[1] LI Lin yu, WU Zhang hua, YU Guo yao, DAI Wei, LUO Er cang.
Experimental investigation on electroacoustic conversion characteristic of linear compressor
[J]. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2016, 50(8): 1529-1536.
[2] GUO Yi-nan, LEI Gang, WANG Tian-xiang, WANG Kai, SUN Da-ming. Numerical simulation of Taconis thermoacoustic oscillation[J]. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2014, 48(2): 327-333.
[3] ZHAO Rui-dong, WU Zhang-hua, LUO Er-cang, DAI Wei. Study on the basic experimental rig for thermoacoustic system[J]. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2013, 47(2): 308-313.
[4] YAO Hua, SHENG De-ren, CHEN Jian-hong, LI Wei, HONG Rong-hua. Thermodynamic analysis of gravity heatpipe steam generator[J]. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2012, 46(9): 1678-1684.
[5] YAO Hua, SHENG De-ren, LIN Zhang-xin, SONG Si-yuan,CHEN Jian-hong, LI Wei. Thermodynamic performance analysis of associated energy
 combined cycle system in ironmaking process
[J]. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2011, 45(11): 2008-2013.
[6] NIE Xiang-hong, YU Xiao-li, CHEN Ping-lu, FANG Yi-dong. Theoretical analysis of available energy and efficiency in liquid
nitrogen engine cycle
[J]. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2010, 44(11): 2159-2163.
[7] HU Jun-Jiang, SHU Xiao-Chi, NIE Xiang-Gong, et al. Feasibility of parallel airpowered and diesel hybrid engine[J]. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2009, 43(09): 1632-1637.