Please wait a minute...
JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE)
    
Repetitive control strategy of DSTATCOM based on error regulator
YANG Kun, WANG Yue, CHEN Guo-zhu
College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
Download:   PDF(1607KB) HTML
Export: BibTeX | EndNote (RIS)      

Abstract  

Cascaded distribution static synchronous compensator (DSTATCOM) is controlled by the combination of proportional-integral (PI) and repetitive control strategy. An error regulator was introduced to eliminat the effects of its bad dynamic and stability performance. In the dynamic process of instruction-switching, the input signal of repetitive controller was dynamically regulated by hysteresis and attenuator according to the current amplitude error of reactive axis, to reduce the influence of repetitive controller on PI feedforward path. When in a steady state, error regulator didn’t response to ensure the static compensation accuracy. Thus the dynamic performace of the composite controller was improved under the premise of making sure stability. Simulation and experimental results verified the feasibility of the error regulator in improving the controller’s dynamic response.



Published: 01 June 2015
CLC:  TM 762  
Cite this article:

YANG Kun, WANG Yue, CHEN Guo-zhu. Repetitive control strategy of DSTATCOM based on error regulator. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2015, 49(6): 1087-1092.

URL:

http://www.zjujournals.com/eng/10.3785/j.issn.1008-973X.2015.06.012     OR     http://www.zjujournals.com/eng/Y2015/V49/I6/1087


基于误差调节的DSTATCOM重复控制策略

 链式配电静止同步补偿器(DSTATCOM)采用比例积分(PI)与重复控制相结合的复合控制策略.为了消除装置动态性能和稳定性不佳的影响,设计误差调节器.在指令切换的动态过程中,利用滞环和衰减器,根据无功轴电流误差幅值对重复控制器输入信号进行快速调节,减小重复控制延时对PI前馈通路的影响.稳态时误差调节器不响应,保证稳态补偿精度,从而在保证稳定性的前提下提高复合控制器的动态性能.通过仿真和实验分析验证了误差调节器在提高复合控制器动态响应方面的有效性.

[1] 韩英铎,严干贵,姜齐荣,等.信息电力与FACTS及DFACTS技术[J].电力系统自动化,2000,24(19): 17.
HAN Ying-duo,YAN Gan-gui,JIANG Qi-rong,et al. Electric power in information society and FACTS and DFACTS[J].Automation of Electric Power Systems,2000,24(19): 17.
[2] 杨昆,陈磊,陈国柱.DSTATCOM补偿不平衡负载分序控制策略[J].电力自动化设备,2012,32(7): 36-41.
YANG Kun,CHEN Lei,CHEN Guo-zhu.Individual sequence control of DSTATCOM compensation for unbalanced load[J].Electric Power Automation Equipment,2012,32(7): 36-41.
[3] 袁佳歆,陈柏超,万黎,等.利用配电网静止无功补偿器改善配电网电能质量的方法[J].电网技术,2004,28(19): 81-84.
YUAN Jia-xin, CHEN Bai-chao, WAN Li, et al. The method to improve power quality of distribution system by distribution static compensator[J]. Power System Technology, 2004, 28(19): 81-84.
[4] SANO K,TAKASAKI M.A transformerless D-STATCOM based on a multivoltage cascade converter requiring no DC sources[J].IEEE Transactions on Power Electronics, 2012,27(6): 2783-2795.
[5] LI C B, XIAO L W, CAO Y J, et al. Optimal allocation of multi-type FACTS devices in power systems based on power flow entropy[J]. Journal of Modern Power Systems and Clean Energy, 2014, 2(2): 173-180.
[6] MAHARJAN L, INOUE S, AKAGI H. A transformerless energy storage system based on a cascade multilevel PWM converter with star configuration[J]. IEEE Transactions on Industrial Applications, 2008, 44(5): 1621-1630.
[7] 中华人民共和国国家标准.GB/T 14549-93电能质量公用电网谐波[S].北京:中国标准出版社,1994.
[8] 中华人民共和国电力行业标准.DL/T 1215.1-2013 链式静止同步补偿器[S].北京:中国电力出版社,2013.
[9] 杨昆,陈国柱.基于重复控制的DSTATCOM补偿电流控制[J].电力系统自动化,2013,37(10):80-85.
YANG Kun,CHEN Guo-zhu.Compensation current control for DSTATCOM based on repetitive control [J]. Automation of Electric Power Systems,2013,37(10): 80-85.
[10] CHANG G W, CHEN S K. An analytical approach for characterizing harmonic and interharmonic currents generated by VSI-fed adjustable speed drives [J]. IEEE Transactions on Power Delivery, 2005, 20(5): 2585-2593.
[11] ZHANG B, WANG D W, ZHOU K L, et al. Linear phase lead compensation repetitive control of a CVCF PWM inverter [J]. IEEE Transactions on Industry Electronics, 2008, 55(4): 1595-1602.
[12] 杨昆,陈磊,陈国柱.单相SVG高性能补偿电流控制技术[J].浙江大学学报:工学版,2013,47(2) : 339-344.
YANG Kun,CHEN Lei,CHEN Guo-zhu.High performance compensation current control strategy of single-phase SVG[J].Journal of Zhejiang University: Engineering Science,2013,47(2): 339-344.
[13] 滕国飞,肖国春,张志波,等.采用重复控制的LCL型并网逆变器单闭环电流控制[J].中国电机工程学报,2013,33(24): 13-21.
TENG Guo-fei, XIAO Guo-chun, ZHANG Zhi-bo, et al. A single-loop current control method for LCL-filtered grid-connected inverters based on the repetitive controller [J]. Proceedings of the Chinese Society for Electrical Engineering, 2013, 33(24): 13-21.
[14] 谢川,张靖,王智强,等.适于重复控制固定采样点数的数字锁相方法[J].浙江大学学报:工学版,2011,45(5): 789-793.
XIE Chuan,ZHANG Jing,WANG Zhi-qiang,et al.Digital PLL with fixed number of sampling points for repetitive control algorithm[J].Journal of Zhejiang University: Engineering Science,2011,45(5): 789-793.
[1] XIE Peng kang, CHEN Heng lin, CHEN Guo zhu. Magnetic loss characteristics of three phase hexastyle magnetically controlled reactors with hexastyle and parallel valve structure[J]. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2015, 49(12): 2418-2424.
[2] CHEN Xiao, Chen Heng-Lin, CHEN Guo-zhu. Three-phase four-wire shut active power filter with coupled inductors[J]. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2015, 49(8): 1529-1536.
[3] WANG Yue,YANG Kun,YANG Hua,CHEN Guo-zhu. Implementation of universal SPWM pulse generator and novel method for pulse competition elimination[J]. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2014, 48(11): 2087-2093.
[4] WANG Zhi-heng,YANG Qing-hua,HU Xin-hua,RUAN Jian. Derating characteristics of metal cold extrusion with function of chattering[J]. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2014, 48(11): 1983-1993.
[5] WANG Zhi-heng,YANG Qing-hua,HU Xin-hua,RUAN Jian. Derating characteristics of metal cold extrusion with function of chattering[J]. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2014, 48(6): 3-.
[6] WANG Yue,YANG Kun,YANG Hua,CHEN Guo-zhu. SPWM pulse generator and novel method for pulse competition elimination[J]. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2014, 48(6): 2-.
[7] ZHONG Xiao-jian, FENG Xia, XU Qun-wei, CHEN Guo-zhu. Control strategy based on ABC frame for three-phase four-wire shunt active power filter[J]. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2014, 48(5): 889-895.
[8] WANG Yue, YANG Kun, ZHONG Xiao-jian, CHEN Guo-zhu. Shunt APF control strategy based on multiple synchronous rotating transform[J]. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2013, 47(4): 705-710.
[9] YANG Kun, CHEN Lei, CHEN Guo-zhu. High performance compensation current control strategy of #br# single-phase SVG[J]. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2013, 47(2): 339-344.