摘要:

针对直流变换器(DC/DC)中变压器绕组之间的高压绝缘问题,提出采用高压电缆作为同轴变压器绕组的绝缘方法和该种同轴变压器的优化设计方法.考虑直流风电场的实际情况,对应用于模块化隔离型DC/DC变换器的中频同轴变压器进行设计,对变压器的结构和参数优化进行研究,得出变压器优化设计的最优解.在仿真实验中,利用Ansys软件进行变压器的温度场仿真.以额定容量250 kV·A的中频同轴变压器为例,进行优化设计.结果表明:变压器体积为0.022 3 m3,重量为47.11 kg,变压器满载时的最高温度为98.5℃,励磁电感和泄漏电感值均满足设计要求,验证了同轴变压器设计方法的有效性和可行性.

Abstract:

An insulation method using high voltage insulated cable as the coaxial transformer winding was proposed aiming at the problem of high voltage insulation between transformer windings in DC/DC converters. The design and optimization method of the transformer was propased. A medium frequency coaxial transformer was designed in modular isolated DC/DC converter (MIDC) considering the actual pure DC wind farm. Transformer structure and parameter optimization was analyzed, and the optimization results were obtained. Ansys temperature field simulation of the transformer was conducted. A rated 250 kV·A medium frequency coaxial transformer was designed. Results showed that the optimal volume and weight were 0.022 3 m3 and 47.11 kg, the highest temperature of the transformer was 98.5℃ under full-load working condition, and the magnetic inductance and leakage inductance value both met the design requirements. Simulations verified the validity and feasibility of the proposed coaxial transformer design method.

收稿日期: 2016-07-01 出版日期: 2017-08-16
CLC:  TM76  
通讯作者: 江道灼,男,教授.ORCD:0000-0002-9783-8496.     E-mail: dzjiang@zju.edu.cn
作者简介: 唐伟佳(1990-),女,硕士,从事高压直流输电等研究.ORCD:0000-0002-0075-4174.E-mail:wjtang@zju.edu.cn
服务  
把本文推荐给朋友
加入引用管理器
E-mail Alert
作者相关文章  

引用本文:

唐伟佳, 江道灼, 尹瑞, 梁一桥, 王玉芬. 模块化隔离型直流变换器的同轴变压器设计[J]. 浙江大学学报(工学版), 2017, 51(8): 1646-1652.

TANG Wei-jia, JIANG Dao-zhuo, YIN Rui, LIANG Yi-qiao, WANG Yu-fen. Design of coaxial transformer for modular isolated DC/DC converters. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2017, 51(8): 1646-1652.

链接本文:

http://www.zjujournals.com/eng/CN/10.3785/j.issn.1008-973X.2017.08.022        http://www.zjujournals.com/eng/CN/Y2017/V51/I8/1646

[1] 江道灼,谷泓杰,尹瑞,等.海上直流风电场研究现状及发展前景[J].电网技术,2015(9):2424-2431. JIANG Dao-zhuo, GU Hong-jie, YIN Rui, et al. Research status and developing prospect of offshore wind farm with pure DC systems[J].Power System Technology, 2015(9):2424-2431.
[2] BAHMANI M A, THIRINGER T, KHAREZY M, et al.Design methodology and optimization of a medium frequency transformer for high power DC-DC applications[C]//Proceedings of Applied Power Electronics Conference and Exposition.Charlotte:APEC, 2015:2532-2539.
[3] ORTIZ G, BIELA J, KOLAR J W.Optimized design of medium frequency transformers with high isolation requirements[C]//Proceedings of Industrial Electronics Society.Glendale:IECON, 2010:631-638.
[4] ORTIZ G, BIELA J, BORTIS D, et al.1 Megawatt,20 kHz,isolated,bidirectional 12kV to 1.2kV DC-DC converter for renewable energy applications[C]//Proceedings of Power Electronics Conference.Sapporo:IPEC, 2010:3212-3219.
[5] ERNESTOL BARRIOS, ALFREDO URSUA, LUIS MARROYO, et al.Analytical design methodology for litz-wired high-frequency power transformer[J].IEEE Transactions on Industrial Electronics, 2015, 62(4):2103-2113.
[6] K SANO, M TAKASAKI. A boost conversion system consisting of multiple DC-DC converter modules for interfacing wind farms and HVDC transmission[C]//Proceedings of Energy Conversion Congress and Exposition.Denver:ECCE, 2013:2613-2618.
[7] PRASAI A, YIM JUNG-SIK, et al. A new architecture for offshore wind farms[C]//Proceedings of PowerElectronics and Applications European Conference. Aalborg:EPE, 2007:1198-1204.
[8] YAMANAKA T, MARUYAMA S, et al. The development of DC +/-500kV XLPE cable in consideration of the space charge accumulation[C]//Proceedings of the International Conference on Properties and Applications of Dielectric Materials.Nagoya:ICPADM, 2003:689-694.
[9] RAULS M S, NOVOTNY D W, et al.Design considerations for high-frequency coaxial winding power transformers[J]. IEEE Transactions on Industry Applications, 1993, 29(2):375-381.
[10] WALTRICH G, DUARTE JL, HENDRIX M.Design of symmetrical high-frequency coaxial wound transformer for multiport Converters[C]//Proceedings of Power Electronics Conference.Sapporo:IPEC, 2010:3151-3157.
[11] WATER W, LU J.Shielding analysis of high-frequency coaxial transformers used for electric vehicle on-board charging systems[J].IEEE Transactions on Magnetics, 2013, 49(7):4005-4008.
[12] 沙占友,孟志永,安国臣.超微晶磁芯及其在开关电源中的应用[EB/OL].[2016/4/10].http://www.cediy.com/webHtml/Article/power/521520060506112600.html. SHA Zhan-you, MENG Zhi-yong, AN Guo-chen. Ultra-fine crystalline core and its application in the switching power supply[EB/OL].[2016/4/10]. http://www.cediy.com/webHtml/Article/power/521520060506112600.html.
[13] CELANESE. Datasheet of CoolPoly D thermally conductive polyphenylene sulfide (PPS)[EB/OL].[2016/4/10]. http://www.coolpolymers.com/.
[14] KAYE G W C, LABY T H. Chapter 2 general physics[EB/OL].[2016/4/10]. http://www.kayelaby.npl.co.uk/general_physics/.
[15] TOURKHANI F, VIAROUGE P.Accurate analytical model of winding losses in round litz wire windings[J].IEEE Transactions on Magnetics, 2001, 37(1):538-543.
[16] HAYT W H. Engineering Electromagnetics[M]. Atlanta:Mcgraw-Hill Press, 1989:387-389.

[1] 周驰, 李颖晖, 郑无计, 武朋玮, 董泽洪. 电力系统稳定域确定及算法特性研究[J]. 浙江大学学报(工学版), 2019, 53(1): 200-206.
[2] 卢昕, 程雨诗, 张天晨, 徐文渊. 面向配电网分布式控制的轻量级身份认证技术[J]. 浙江大学学报(工学版), 2018, 52(6): 1177-1184.
[3] 张任, 胥芳, 潘国兵, 王坚锋. 采用HHT-LES算法的交流微网电压暂降快速检测[J]. 浙江大学学报(工学版), 2017, 51(12): 2429-2435.