Please wait a minute...
浙江大学学报(工学版)  2018, Vol. 52 Issue (6): 1167-1176    DOI: 10.3785/j.issn.1008-973X.2018.06.016
电气工程     
基于“第二类”双重移相控制的双有源桥DC-DC变换器
傅仕航, 侯庆会, 岳奥飞, 石健将
浙江大学 电气工程学院, 浙江 杭州 310027
Dual active bridge DC-DC converter based on second dual-phase-shifting control
FU Shi-hang, HOU Qing-hui, YUE Ao-fei, SHI Jian-jiang
College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
 全文: PDF(4567 KB)   HTML
摘要:

在双有源桥(DAB)“第二类”双重移相(SDPS)控制的研究基础上,以回流功率最小为优化目标,分析并推导出不同负载条件下回流功率的数学模型,提出回流功率最小化的控制策略.在该策略下,“第二类”双重移相控制的电流应力比第一类的更小,不仅可以降低开关管器件的电流应力,减少磁性元件的损耗,还可以提高变换器的效率.研制小功率实验平台,开展实验验证.实验结果表明,相对于传统的单移相控制和“第一类”双重移相控制,该控制策略显著提升了变换器电流应力、磁性损耗和效率等方面的性能.

Abstract:

A reflux power optimization control strategy based on the existing research work of the second-dual-phase-shifting (SDPS) control of dual active bridge (DAB). The reflux power was optimized according to the derived mathematical model of reflux power on conditions of different loads. Current stress of the second-dual-phase-shifting control was smaller under this strategy compared with the first-dual-phase-shifting control. The strategy can not only make the requirements of switching devices lower, reduce the loss of magnetic elements, but also improve the efficiency of converter. The control method was verified in a small power experiment platform. The experimental results show that the control strategy can improve property of current stress, magnetic loss and efficiency of converter, which is better than single and the first dual-phase-shift controls.

收稿日期: 2017-03-16 出版日期: 2018-06-20
CLC:  TM46  
基金资助:

国家自然科学基金资助项目(51277162).

通讯作者: 石健将,男,教授,博导,从事电力电子变换器的研究.orcid.org/0000-0002-9501-9470.     E-mail: jianjiang@zju.edu.cn
作者简介: 傅仕航(1991-),男,硕士生,从事固态变压器的研究.orcid.org/0000-0002-0300-6235.E-mail:bellnorth@zju.edu.cn
服务  
把本文推荐给朋友
加入引用管理器
E-mail Alert
作者相关文章  

引用本文:

傅仕航, 侯庆会, 岳奥飞, 石健将. 基于“第二类”双重移相控制的双有源桥DC-DC变换器[J]. 浙江大学学报(工学版), 2018, 52(6): 1167-1176.

FU Shi-hang, HOU Qing-hui, YUE Ao-fei, SHI Jian-jiang. Dual active bridge DC-DC converter based on second dual-phase-shifting control. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2018, 52(6): 1167-1176.

链接本文:

http://www.zjujournals.com/eng/CN/10.3785/j.issn.1008-973X.2018.06.016        http://www.zjujournals.com/eng/CN/Y2018/V52/I6/1167

[1] DE DONCKER R W, DIVAN D M, KHERALUWALA M H. A three-phase soft-switched high-power-density DC/DC converter for high-power applications[J]. IEEE Transactions on Industry Applications, 1991, 27(1):63-73.
[2] KRISMER F, KOLAR J W. Efficiency-optimized high-current dual active bridge converter for automotive applications[J]. IEEE Transactions on Industrial Electronics, 2012,59(7):2745-2760.
[3] ZHAO B, SONG Q, LIU W H, et al. Next-generation multi-functional modular intelligent UPS system for smart grid[J]. IEEE Transactions on Industrial Electronics, 2013, 60(9):3602-3618.
[4] GARCIA P, FERNANDEZ L M, GARCIA C A, et al. Energy management system of fuel-cell-battery hybrid tramway[J]. IEEE Transactions on Industrial Electronics, 2010,57(12):4013-4023.
[5] CHIU H J,LIN L W.A bidirectional DC-DC converter for fuel cell electric vehicle driving system[J]. IEEE Transactions on Power Electronics, 2006, 21(4):950-958.
[6] 黄珺,王跃,李卓强,等.基于三重移相控制的双主动全桥直流变换器优化调制策略[J].中国电机工程学报,2016,36(6):1658-1666. HUANG Jun, WANG Yue, LI Zhuo-qiang, et al. Bidirectional full-bridge DC-DC converters with dual-phase-shifting control and its backflow power characteristicanalysis[J]. Proceedings of the CSEE, 2016, 36(6):1658-1666.
[7] JAIN A K, AYYANAR R. PWM control of dual active bridge:comprehensive analysis and experimental verification[J]. IEEE Transactions on Power Electronics, 2011, 26(4):1215-1227.
[8] XIE Y H, SUN J, FREUDENBERG J S. Power flow characterization of a bidirectional isolated high-power DC/DC converter over a wide operating range[J]. IEEE Transactions on Power Electronics, 2010, 25(1):54-66.
[9] BAI H, MI C. Eliminate reactive power and increase system efficiency of isolated bidirectional dual-active-bridge DC-DC converters using novel dual-phase-shift control[J]. IEEE Transactions on Power Electronics, 2008, 23(6):2905-2314.
[10] MI C, BAI H, WANG C, et al. Operation, design and control of dual H-bridge-based isolated bidirectional DC-DC converter[J]. IET Power Electronics, 2008, 1(4):507-517.
[11] ZHAO,B, SONG Q, LIU W H. Power characterization of isolated bidirectional dual-active-bridge DC-DC converter with dual-phase-shift control[J]. IEEE Transactions on Power Electronics, 2012, 27(9):4172-4176.
[12] 赵彪,于庆广,孙伟欣.双重移相控制的双向全桥DC-DC变换器及其功率回流特性分析[J].中国电机工程学报,2012,32(12):43-50. ZHAO Biao, YU Qing-guang, SUN Wei-xin. Bidirectional full-bridge DC-DC converters with dual-phase-shifting control and its backflow power characteristic analysis[J]. Proceedings of the CSEE, 2012, 32(12):43-50.
[13] CHUNG I Y,LIU W X,ANDRUS M,et al.Integration of a bi-directional dc-dc converter model into a large-scale system simulation of a shipboard MVDC power system[C]//Proceedings of ESTS. Baltimore, MD:IEEE, 2009:318-325.
[14] JALBRZYKOWSKI S, BOGDAN A, CITKO T. A dual full-bridge resonant class-E bidirectional DC-DC converter[J].IEEE Transactions on Industrial Electronics, 2011, 58(9):3879-3883.
[15] ZHAO B, SONG Q, LIU W H, et al. Current-stress-optimized switching strategy of isolated bidirectional DC-DC converter with dual-phase-shift control[J]. IEEE Transactions on Industrial Electronics, 2013,60(10):4458-4467.
[16] 张勋,王广柱,商秀娟,等.双向全桥DC-DC变换器回流功率优化的双重移相控制[J].中国电机工程学报,2016,36(4):1090-1097. ZHANG Xun, WANG Guang-zhu, SHANG Xiu-juan, et al. An optimized strategy based on backflow power of bi-directional dual-active-bridge DC-DC converters with dual-phase-shifting control[J]. Proceedings of the CSEE, 2016, 36(4):1090-1097.
[17] WU K, SILVA C W D, DUNFORD W G. Stabilityanalysis of isolated bidirectional dual active full-bridge DC-DC converter with triple phase-shift control[J].IEEE Transactions on Power Electronics, 2012, 27(4):2007-2017.
[18] 侯聂,宋文胜. 全桥隔离DC/DC变换器的三重相移控制及其软启动方法[J]. 中国电机工程学报, 2015,35(23):6113-6121. HOU Nie, SONG Wen-sheng. Full-bridge isolated DC/DC converters with triple-phase-shift control and soft starting control method[J]. Proceedings of the CSEE, 2015, 35(23):6113-6121.
[19] ZHAO B, SONG Q, LIU W H, et al. Universal high-frequency-link characterization and practical fundamental-optimal strategy for dual-active-bridge DC-DC converter under PWM plus phase-shift control[J]. IEEE Transactions on Power Electronics, 2015,30(12):1-1.
[20] HUANG J, WANG Y, LI Z, et al. Unified triple-phase-shift control to minimize current stress andachieve full soft-switching of isolated bidirectionalDC-DC converter[J]. IEEE Transactions on IndustrialElectronics, 2016, 63(7):4169-4179.
[21] HOU N, SONG W, WU M. Minimum-current-stress scheme of dual active bridge DC-DC converter with unified-phase-shift control[J]. IEEE Transactions on Power Electronics, 2016, 31(12):8552-8561.
[22] MYOUNGHO K, ROSEKEIT M, et al. A dual-phase shift control strategy for dual-active-bridge DC-DC converter in wide voltage range[C]//ICPE & ECCE.Jeju:[s.n.], 2011:364-371.
[23] 杨敏.PWM加移相控制双有源全桥双向DC-DC变换器的研究.南京:南京航空航天大学,2013.
[24] 王玉斌,王杉杉,封波,等.基于双重移相控制的双有源DC-DC变换器的最优电流控制[J].电工技术学报,2015,30(14):488-496. WANG Yu-bin, WANG Shan-shan, FENG Bo, et al. Optimal current control strategy of dual-active-bridge DC-DC converter based on dual-phase-shift control[J]. Transactions of China Electrotechnical Society, 2015, 30(14):488-496.

[1] 宿紫鹏, 杨磊, 杨家强, 高敏. 基于开关表决策的APF与TSC混合系统投切控制方法[J]. 浙江大学学报(工学版), 2018, 52(11): 2201-2209.
[2] 徐厚建, 姚文熙. 基于开关管电压检测的图腾柱整流器控制方案[J]. 浙江大学学报(工学版), 2018, 52(9): 1771-1776.
[3] 刘鑫, 郑祥杰, 侯庆会, 石健将. 变压器串并联LLC+Buck级联DC-DC变换器的均流特性[J]. 浙江大学学报(工学版), 2018, 52(4): 806-818.
[4] 李新, 肖龙, 刘国梁, 邵雨亭, 陈国柱. 基于相位补偿和交叉前馈补偿的VSG功率振荡抑制策略[J]. 浙江大学学报(工学版), 2018, 52(3): 569-576.
[5] 袁庆伟, 赵荣祥. 考虑死区的三相PWM逆变器共模电压抑制技术[J]. 浙江大学学报(工学版), 2017, 51(11): 2276-2286.
[6] 刘威, 姚文熙, 吕征宇. 半桥三电平LLC谐振变换器的调制方法[J]. 浙江大学学报(工学版), 2017, 51(8): 1653-1661.