Parallel MRI based on combination of nonlinear GRAPPA and SENSE" /> 结合非线性GRAPPA与SENSE的并行磁共振成像
Please wait a minute...
浙江大学学报(工学版)
计算机技术﹑电信技术     
结合非线性GRAPPA与SENSE的并行磁共振成像
蒋明峰1, 朱礼涛1, 汪亚明1, 夏灵2, 龚莹岚2
1. 浙江理工大学 信息学院, 浙江 杭州 310018;2. 浙江大学 生物医学工程系, 浙江 杭州 310027
Parallel MRI based on combination of nonlinear GRAPPA and SENSE
JIANG Ming-feng1, ZHU Li-tao1, WANG Ya-ming1, XIA Ling2, GONG Ying-lan2
1. School of Information Science and Technology, Zhejiang Sci-Tech University, Hangzhou 310018, China; 2. Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China
 全文: PDF(1988 KB)   HTML
摘要:

针对SENSE并行磁共振成像中采用补零缺失数据方法估计敏感度分布不准确性的问题,提出采用非线性GRAPPA方法估算缺失的K空间欠采样数据.计算并行线圈的敏感度分布,将这些敏感度分布应用于SENSE并行磁共振成像.采用不同加速因子的脑磁共振K空间欠采样数据以验证提出算法的重建性能.实验结果表明,与单一的非线性GRAPPA和SENSE重建算法相比,该混合NLGRAPPA-SENSE算法在加速因子较大时可以重建出更加准确的磁共振图像,具有更低的噪声功率(AP)和更高的信噪比(SNR)性能.

Abstract:

The nonlinear GRAPPA method was applied to estimate the undersampled K-space data in order to overcome the inaccuracy of sensitivity map of each coil calculated by zero-padding method. Then the accurate sensitivity map of each coil was calculated. The sensitivity encoding (SENSE) method was adopted to reconstruct the MR image from the under-sampled K-space data based on the accurate sensitivity map. The proposed hybrid technique was tested on MR brain image reconstructions at various acceleration rates. Experimental results show that the proposed method can achieve significant improvements in reconstruction accuracy when compared with the nonlinear GRAPPA and SENSE methods, with lower artificial power (AP) and higher signal to noise ratio (SNR).

出版日期: 2014-10-01
:  TP 391  
基金资助:

国家“973”重点基础研究发展规划资助项目(2010CB732502);国家自然科学基金资助项目(61070063、61272311);浙江省自然科学基金资助项目(LY14F010022);浙江理工大学“521”人才培养计划资助项目.

作者简介: 蒋明峰(1977—), 男, 副教授,从事生物医学图像的研究. E-mail: m.jiang@zstu.edu.cn
服务  
把本文推荐给朋友
加入引用管理器
E-mail Alert
RSS
作者相关文章  

引用本文:

蒋明峰, 朱礼涛, 汪亚明, 夏灵, 龚莹岚. 结合非线性GRAPPA与SENSE的并行磁共振成像[J]. 浙江大学学报(工学版), 10.3785/j.issn.1008-973X.2014.10.022.

JIANG Ming-feng, ZHU Li-tao, WANG Ya-ming, XIA Ling, GONG Ying-lan.

Parallel MRI based on combination of nonlinear GRAPPA and SENSE
. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 10.3785/j.issn.1008-973X.2014.10.022.

链接本文:

http://www.zjujournals.com/eng/CN/10.3785/j.issn.1008-973X.2014.10.022        http://www.zjujournals.com/eng/CN/Y2014/V48/I10/1865

[1] CARLSON J W. An algorithm for NMR imaging reconstruction based on multiple RF receiver coils [J]. Journal of Magnetic Resonance, 1987, 74(2): 376-380.
[2] 刘晓芳,叶修梓,张三元,等.并行磁共振图像的非二次正则化保边性重建[J].浙江大学学报:工学版,2012, 46(11): 2044-2051.
LIU Xiao-fang, YE Xiu-zi, ZHANG San-yuan, et al. Non-quadratic regularized edge-preserving reconstruction for parallel magnetic resonance image [J]. Journal of Zhejiang University: Engineering Science, 2012, 46(11): 2044-2051.
[3] SODICKSON D K, MANNING W J. Simultaneous acquistion of spatial harmonics (SMASH): ultra-fast imaging with radiofrequency coil arrays [J]. Magnetic Resonance in Medicine,1997, 38(4): 591-603.
[4] GRISWOLD M A, JAKOB P M, HEIDEMAN R M. Generalized autocalibrating partiauy parallel acquisitions(GRAPPA) [J]. Magnetic Resonance in Medicine, 2002, 47(6): 1202-1210.
[5] GRISWOLD M A, JAKOB P M, NITTKA M. Partially parallel imaging with localized sensitivities(PILS) [J]. Magnetic Resonance in Medicine, 2000, 44(4): 602-609.
[6] PRUESSMANN K P, WEIGER M, SCHEIDEGGER M B. SENSE: sensitivity encoding for fast MRI [J]. Magnetic Resonance in Medicine, 1999, 42(5): 952-962.
[7] KYRIAKOS W E, PANYCH L P, KACHER D F. Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP) [J]. Magnetic Resonance in Medicine, 2000, 44(2): 301-308.
[8] MCKENZIE C A, YEH E N, OHLIGER M A. Self-calibrating parallel imaging with automatic coil sensitivity extraction [J]. Magnetic Resonance in Medicine, 2002, 47(3): 529-538.
[9] BRUNO M. UNFOLD-SENSE: a parallel MRI method with self-calibration and artifact suppression [J]. Magnetic Resonance in Medicine, 2004, 52(2): 310-320.
[10] YING L L, SHENG J H. Joint image reconstruction and sensitivity estimation in SENSE (JSENSE) [J]. Magnetic Resonance in Medicine, 2007, 57(6): 1196-1202.
[11] CHANG Y C, LIANG D, YING L L. Nonlinear GRAPPA: a kernel approach to parallel MRI reconstruction [J]. Magnetic Resonance in Medicine, 2012, 68(3): 730-740.
[12] MARK B, JUNH Y K. A nonlinear regularization strategy for GRAPPA calibration [J]. Magnetic Resonance Imaging, 2009, 27(1): 137-141.
[13] HOGE W S, DANA H B. Using GRAPPA to improve auto-calibrated coil sensitivity estimation for the SENSE family of parallel imaging reconstruction algorithms [J]. Magnetic Resonance in Medicine, 2008, 60(2): 462-467.
[14] ARTIN U, MARK J M, PATRICK V. ESPIRiT: an eigenvalue approach to autocalibrating parallel MRI: where SENSE meets GRAPPA [J]. Magnetic Resonance in Medicine, 2014, 71(3): 990-1001.
[15] Ji J X., SON J B, RANE S D. PULSAR: a MATLAB toolbox for parallel magnetic resonance imaging using array coils and multiple channel receivers. [J]. Concepts in Magnetic Resonance part B: Magnetic Resonance Engineering, 2007, 31B(1): 24-36.
[16] THUNBERG P, ZETTERBERG P. Noise distribution in SENSE-and GRAPPA reconstructed images: a computer simulation study [J]. Magnetic Resonance Imaging , 2007, 25(7): 1089-1094.
[1] 何雪军, 王进, 陆国栋, 刘振宇, 陈立, 金晶. 基于三角网切片及碰撞检测的工业机器人三维头像雕刻[J]. 浙江大学学报(工学版), 2017, 51(6): 1104-1110.
[2] 王桦, 韩同阳, 周可. 公安情报中基于关键图谱的群体发现算法[J]. 浙江大学学报(工学版), 2017, 51(6): 1173-1180.
[3] 尤海辉, 马增益, 唐义军, 王月兰, 郑林, 俞钟, 吉澄军. 循环流化床入炉垃圾热值软测量[J]. 浙江大学学报(工学版), 2017, 51(6): 1163-1172.
[4] 毕晓君, 王佳荟. 基于混合学习策略的教与学优化算法[J]. 浙江大学学报(工学版), 2017, 51(5): 1024-1031.
[5] 王亮, 於志文, 郭斌. 基于双层多粒度知识发现的移动轨迹预测模型[J]. 浙江大学学报(工学版), 2017, 51(4): 669-674.
[6] 廖苗, 赵于前, 曾业战, 黄忠朝, 张丙奎, 邹北骥. 基于支持向量机和椭圆拟合的细胞图像自动分割[J]. 浙江大学学报(工学版), 2017, 51(4): 722-728.
[7] 黄正宇, 蒋鑫龙, 刘军发, 陈益强, 谷洋. 基于融合特征的半监督流形约束定位方法[J]. 浙江大学学报(工学版), 2017, 51(4): 655-662.
[8] 蒋鑫龙, 陈益强, 刘军发, 忽丽莎, 沈建飞. 面向自闭症患者社交距离认知的可穿戴系统[J]. 浙江大学学报(工学版), 2017, 51(4): 637-647.
[9] 穆晶晶, 赵昕玥, 何再兴, 张树有. 基于凹凸变换与圆周拟合的重叠气泡轮廓重构[J]. 浙江大学学报(工学版), 2017, 51(4): 714-721.
[10] 戴彩艳, 陈崚, 李斌, 陈伯伦. 复杂网络中的抽样链接预测[J]. 浙江大学学报(工学版), 2017, 51(3): 554-561.
[11] 刘磊, 杨鹏, 刘作军. 采用多核相关向量机的人体步态识别[J]. 浙江大学学报(工学版), 2017, 51(3): 562-571.
[12] 郭梦丽, 达飞鹏, 邓星, 盖绍彦. 基于关键点和局部特征的三维人脸识别[J]. 浙江大学学报(工学版), 2017, 51(3): 584-589.
[13] 王海军, 葛红娟, 张圣燕. 基于核协同表示的快速目标跟踪算法[J]. 浙江大学学报(工学版), 2017, 51(2): 399-407.
[14] 张亚楠, 陈德运, 王莹洁, 刘宇鹏. 基于增量图形模式匹配的动态冷启动推荐方法[J]. 浙江大学学报(工学版), 2017, 51(2): 408-415.
[15] 刘宇鹏, 乔秀明, 赵石磊, 马春光. 统计机器翻译中大规模特征的深度融合[J]. 浙江大学学报(工学版), 2017, 51(1): 46-56.