摘要:

超声编码激励通过发射具有编码形式的超声信号,可以有效提高医学超声成像系统的信噪比、帧频和探查深度等性能指标.为了给医学超声成像系统的研究与设计提供参考,对目前编码激励的研究成果进行了总结.在介绍编码激励基本原理和发射编码序列基本特性的基础上,介绍了编码激励在信噪比增益、激励码型和组织非线性效应方面的理论研究进展,之后针对编码激励技术在传统B型成像、弹性成像、高频超声成像、高帧频成像、合成孔径成像、血流成像、谐波成像及消除超声图像杂斑等多个技术方面的应用情况进行了评述,最后对编码激励技术的发展前景进行了展望.

Abstract:

By transmitting coded ultrasound, coded excitation improves the signal-to-noise ratio, the frame rate and the penetration of the medical ultrasound imaging device. In order to provide guidelines to researchers in the field of medical ultrasound imaging, the newly advance of medical ultrasonic coded excitation was reviewed in this work. Introducing the basic principles of coded excitation and the characteristics of different types of code, gain in signal-to-noise ratio obtained by coded excitation, designing of types of code, tissue attenuation and nonlinear effect’s influence on pulsed compression were depicted. And the applications of coded excitation in B-mode ultrasound, elastography, high frequency ultrasound imaging, high frame rate imaging, synthetic aperture imaging, blood flow imaging and speckle reduction were reviewed regarding the properties of the coded excitation. Finally, advances of coded excitation was explored and prospected.

出版日期: 2011-03-17
:  R 318.04  
通讯作者: 郑音飞,男,讲师.     E-mail: zyfnjupt@126.com
作者简介: 周浩(1984—),男,内蒙人,博士生,从事医学超声成像的研究.E-mail: bmezhou@163.com
服务  
把本文推荐给朋友
加入引用管理器
E-mail Alert
RSS
作者相关文章  

引用本文:

周浩, 王友钊, 郑音飞. 医学超声编码激励技术研究进展[J]. J4, 2011, 45(2): 387-391.

Zhou Hao, Wang You-zhao, Zheng Yin-fei. The advance of medical ultrasonic coded excitation. J4, 2011, 45(2): 387-391.

链接本文:

http://www.zjujournals.com/eng/CN/10.3785/j.issn.1008-973X.2011.02.031        http://www.zjujournals.com/eng/CN/Y2011/V45/I2/387

[1] CHIAO Y, HAO X.Coded excitation for diagnostic ultrasound: A system developer’s perspective [J]. IEEE Transactions on Ultrasonics Ferroelectrics, and Frequency Control, 2005, 52(2): 160-170.
[2] 彭旗宇,高上凯.医学超声成像中的编码激励技术及其应用[J].生物医学工程学杂志,2005,22(1): 175180. PENG Qiyu, GAO Shangkai.Coded excitation and its applications in medical ultrasound imaging [J]. Journal of Biomedical Engineering, 2005, 22(1): 175-180.
[3] O’DONNELL M.Coded excitation system for improving the penetration of realtime phasedarray imaging systems [J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1992, 39(3): 341-351.
[4] PEDERSEN M, MISARIDIS T, JENSEN J.Clinical comparison of pulse and chirp excitation [C]∥ Proceedings of the IEEE Ultrasonics Symposium.Munich: IEEE, 2002: 1673-1676.
[5] O’DONNELL M, WANG Y.Coded excitation methods in biomedical ultrasound [C]∥ 2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano, Arlington: IEEE, 2004: 37-40.
[6] ZHAO H, MO L, GAO S.Barkercoded ultrasound color flow imaging: Theoretical and practical design considerations [J]. IEEE Transactions on Ultrasonics, Ferroelectric and Frequency Control, 2007, 54(2): 319-331.
[7] LAMBOUL B, BENNETT M, ANDERSON T, et al.Basic considerations in the use of coded excitation for color flow imaging applications [J]. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 2009, 56(4): 727-737.
[8] 谷金宏,万明习,王素品,等.基于调频信号发射的超声造影剂谐波成像方法[J].声学学报,2006, 31(3): 240-246.
GU Jinhong, WAN Mingxi, WANG Supin, et al.Ultrasound contrast agent harmonic imaging method based on frequencymodulated signal excitation [J]. Acta Acustica, 2006, 31(3): 240-246.
[9] BORSBOOM J, CHIEN T, BOUAKAZ A.Harmonic chirp imaging method for ultrasound contrast agent [J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2005, 52(2): 241-249.
[10] 赵珩.超声彩色血流成像中编码激励技术的研究 [D].北京:清华大学, 2006: 21-24.
ZHAO Heng.Research on coded excitation in ultrasound color flow imaging system [D]. Beijing: Tsinghua University, 2006: 21-24.
[11] WELLS P.Ultrasound imaging [J]. Physics in Medicine and Biology, 2006, 51(13): R83-R98.
[12] GOLAY M.Complementary Series [J]. IRE Transactions on Information Theory, 1961, 7(2): 82-87.
[13] RUPRECHT J, RUPF M.On the search for good aperiodic binary invertible sequences [J]. IEEE Transactions on Information Theory, 1996, 42(5): 1604-1612.
[14] HUANG S, LI P.Binary code design for highfrequency ultrasound [J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2007, 54(3): 947-956.
[15] COWELL J, FREEAR S.Quinary excitation method for pulse compression ultrasound measurements [J]. Ultrasonics, 2008, 48(2): 98-108.
[16] LEWANDOWSKI M, NOVICKI A. High frequency coded imaging system with RF software signal processing [J]. IEEE Transactions on Ultrasonics, Ferroelectric and Frequency Control, 2008, 55(8): 1878-1882.
[17] WELCH L, FOX M.Practical spread spectrum pulse compression for ultrasonic tissue imaging [J].IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 1998, 45(2): 349-355.
[18] MISARIDIS T, JENSEN J.Use of modulated excitation signals in medical ultrasound. Part I: Basic concepts and expected benefits [J]. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 2005, 52(2): 177-191.
[19] LEAVENS C, WILLIAMS R, BURNS P, et al.The use of phase codes in ultrasound imaging: SNR gain and bandwidth requirements [J]. Applied Acoustics, 2009, 70(10): 1340-1351.
[20] LIU K, GAO S.Searching binary sequences for coded excitation in medical ultrasound [C]∥ Conference Proceedings of the IEEE Engineering in Medicine and Biology Society. Shanghai: IEEE, 2005: 1858-1860.
[21] BRENNER A, ECK K, WILHELM W, et al.Improved resolution and dynamic range in medical ultrasonic imaging using depth dependent mismatched filtering [C]∥ Proceedings of the IEEE Ultrasonics Symposium. Toronto: IEEE, 1997: 1475-1480.
[22] YOO Y, LEE W, SONG, T.A low voltage portable system using modified Golay sequences [C]∥ Proceedings of the IEEE Ultrasonics Symposium. Atlanta: IEEE, 2001: 1469-1472.
[23] LIU J, INSANA M. Coded pulsed excitation for ultrasonic strain imaging [J]. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 2005, 52(2): 231-240.
[24] 刘凯,高上凯.高频超声成像中的编码激励研究[J].北京生物医学工程,2007,26(1): 31-35.
LIU Kai, GAO Shangkai.Study of coded excitation in high frequency ultrasound imaging [J]. Beijing Biomedical Engineering, 2007, 26(1): 31-35.
[25] CHEN X, ZHOU H, WEN S, et al.Increasing average power in medical ultrasonic endoscope imaging system by coded excitation [C]∥ 2008 International Conference on Optical Instruments and Technology: Optical Systems and Optoelectronic Instruments. Beijing: SPIE, 2009: 71562H1-71562H8.
[26] MISARIDIS T, JENSEN J. Spacetime encoding for high frame rate ultrasound imaging [J]. Ultrasonics, 2002(1/8), 40: 593-597.
[27] JIN C, CHEN S, QIN Z.A new coding scheme in coded ultrasound using staggering repetition interval [J]. Journal of Zhejiang UnversitySCIENCE A, 2009, 10(8): 1213-1216.
[28] JENSEN J, HOLM O, JENSEN J, et al. Ultrasound research scanner for realtime synthetic aperture data acquisition [J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2005, 52(5): 881-891.
[29] XIANG L, ZHAO H, GAO S.Barker code in TCD ultrasound systems to improve the sensitivity of emboli detection [J]. Ultrasound in Medicine and Biology, 2009, 35(1): 94-101.
[30] GRAN F, UDESEN J, NIELSEN M, et al. Coded ultrasound for blood flow estimation using subband processing [J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2008, 55(10): 2211-2220.
[31] CHIAO R, MO L, HALL A, et al. Bmode blood flow (BFlow) imaging [C]∥ Proceedings of the IEEE Ultrasonics Symposium. San Juan: IEEE, 2000: 1469-1472.
[32] LEAVENS C, BURNS P N, SHERAR M.Fast bflow imaging: A method for improving frame rate in golay coded bflow imaging [J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2007, 54(1): 2272-2282.
[33] SONG J, KIM S, SOHN H, et al.Coded excitation for ultrasound tissue harmonic imaging [J]. Ultrasonics, 2010, 50(6): 613-619.
[34] OELZE M.Bandwidth and resolution enhancement through pulse compression [J]. IEEE Transactions on Ultrasonics, Ferroeletrics, and Frequency Control, 2007, 54(4): 768-781.
[35] SANCHEZ J, OELZE M.An ultrasonic imaging specklesuppression and contrastenhancement technique by means of frequency compounding and coded excitation [J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2009, 56(7): 1327-1339.

[1] 涂岳文, 陈杭, 付秀泉, 李顶立, 黄超, 汤亚伟, 叶树明. 基于心搏聚类的Holter运动伪差段快速识别算法[J]. J4, 2012, 46(6): 1148-1156.
[2] 陈卫东, 李昕, 刘俊, 郝耀耀, 廖玉玺, 苏煜, 张韶岷, 郑筱祥. 基于数学形态学的眼电信号识别及其应用[J]. J4, 2011, 45(4): 644-649.
[3] 李鹏, 陈裕泉, 胡大可, 郑音飞. 彩色血流成像中编码激励的研究[J]. J4, 2010, 44(6): 1237-1240.