Incineration experiment of medical waste of novel coronavirus pneumonia (COVID-19) in a mobile animal carcass incinerator
Incineration experiment of medical waste of novel coronavirus pneumonia (COVID-19) in a mobile animal carcass incinerator
 全文: PDF 
摘要: Incineration experiment of medical waste was carried out in a mobile animal carcass incinerator. Simulated medical waste (69% cotton, 1.5% wood product, 4.5% mask and 25% moisture) was used as raw material. The temperature trend of first and second combustion chamber, the operating conditions and the emission characteristics of gaseous pollutants were studied. The results indicated that the temperature of first combustion chamber can be maintained at 550–650 °C without external heating, while in the final stage a burner was used to realize the burnout of material. The temperature of the second combustion chamber was always lower than that of the first combustion after the burner stopped working. The concentration of CO emission in flue gas was high due to the low disposal efficiency of the mobile incinerator, while NOX and SO2 emission concentrations were far below the standard limit value (GB 18484-2001).
关键词: Medical wasteIncinerationTemperature fluctuationFurnace conditionGaseous pollutants emission    
Abstract: Incineration experiment of medical waste was carried out in a mobile animal carcass incinerator. Simulated medical waste (69% cotton, 1.5% wood product, 4.5% mask and 25% moisture) was used as raw material. The temperature trend of first and second combustion chamber, the operating conditions and the emission characteristics of gaseous pollutants were studied. The results indicated that the temperature of first combustion chamber can be maintained at 550–650 °C without external heating, while in the final stage a burner was used to realize the burnout of material. The temperature of the second combustion chamber was always lower than that of the first combustion after the burner stopped working. The concentration of CO emission in flue gas was high due to the low disposal efficiency of the mobile incinerator, while NOX and SO2 emission concentrations were far below the standard limit value (GB 18484-2001).
Key words: Medical waste    Incineration    Temperature fluctuation    Furnace condition    Gaseous pollutants emission
出版日期: 2021-03-05
服务  
把本文推荐给朋友
加入引用管理器
E-mail Alert
RSS
作者相关文章  
Shaorui ZhangYanjun ZhangYong Wu

引用本文:

Shaorui ZhangYanjun ZhangYong Wu. Incineration experiment of medical waste of novel coronavirus pneumonia (COVID-19) in a mobile animal carcass incinerator. Waste Disposal & Sustainable Energy, 2021, 3(2): 177-183.

链接本文:

https://www.zjujournals.com/wdse/CN/10.1007/s42768-020-00067-4        https://www.zjujournals.com/wdse/CN/Y2021/V3/I2/177