Gas/particle partitioning of PCDD/Fs in flue gas of
hazardous waste incinerator |
JI Ya, LU Sheng-yong, LIN Xiao-qing, LI Xiao-dong, YAN Jian-hua |
State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, China |
|
|
Abstract The partitioning of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) between gas and solid phase in the flue gas of a hazardous waste incinerator was analyzed. Results show that, gas/particle partitioning of PCDD/Fs at the inlet of baghouse filter is as follows: gas/particle value is 62/38 according to the mass fraction, while it is 76/24 according to the I-TEQ concentration value. The fraction of gas phase PCDD/F congeners decreases with rising chlorination, i.e. highly chlorinated congeners have higher tendencies to attach to the fly ash, while lowly chlorinated congeners occupy a larger fraction of the gas phase. The fractions of gas phase congeners are roughly but not accurately in line with the vapor pressures, which indicates that vapor pressure is one of the main factors to determine the gas/particle partitioning of PCDD/F congeners in flue gas.
|
Published: 01 July 2012
|
|
危险废物焚烧炉烟气中二恶英气固相分配
研究某危险废物焚烧炉烟气中二恶英气固相分配特征.结果表明,布袋除尘器入口烟气中二恶英气固相分配如下:气相二恶英的质量分数平均为62%,固相为38%;气相的毒性当量质量分数平均为76%,固相为24%.各异构体气相质量分数(即每个异构体气相部分质量浓度占该异构体气、固相总质量浓度的百分比)随氯代数的增加而降低,即高氯代异构体更多地附着于飞灰上,低氯代异构体则更多地分布于气相中;气相质量分数的变化趋势基本与蒸汽压相符,表明蒸汽压是决定焚烧烟气中二恶英各异构体气固相分配的主要因素之一.
|
|
[1] MCKAY G. Dioxin characterization, formation and minimisation during municipal solid waste (MSW) incineration: review [J]. Chemical Engineering Journal, 2002, 86: 343-368.
[2] STANMORE B R. The formation of dioxins in combustion systems [J]. Combustion and Flame, 2004, 136: 398-427.
[3] BUEKENS A, HUANG H. Comparative evaluation of techniques for controlling the formation and emission of chlorinated dioxins/furans in municipal waste incineration [J]. Journal of Hazardous Materials, 1998, 62: 1-33.
[4] CHI K H, CHANG S H, HUANG C H, et al. Partitioning and removal of dioxinlike congeners in flue gases treated with activated carbon adsorption [J]. Chemosphere, 2006, 64: 1489-1498.
[5] CHI K H, CHANG M B, CHANG S H. Evaluation of PCDD/F partitioning between vapor and solid phases in MWI flue gases with temperature variation [J]. Journal of Hazardous Materials, 2006, B138: 620-627.
[6] CHI K H, CHANG M B. Evaluation of PCDD/F congener partition in vapor/solid phases of waste incinerator flue gases [J]. Environmental Science and Technology, 2005, 39: 8023-8031.
[7] CHI K H, CHANG M B, CHANGCHIEN G P, et al. Characteristics of PCDD/F congener distributions in gas/particulate phases and emissions from two municipal solid waste incinerators in Taiwan [J]. Science of the Total Environment, 2005, 347: 148-162.
[8] CHEN T, GU Y L, YAN J H, et al. Polychlorinated dibenzopdioxins and dibenzofurans in flue gas emissions from municipal solid waste incinerators in China [J]. Journal of Zhejiang University: Science A, 2008, 9(9): 1296-1303.
[9] YAN J H, PENG Z, LU S Y, et al. Removal of PCDDs/Fs from municipal solid waste incineration by entrainedflow adsorption technology [J]. Journal of Zhejiang University: Science A, 2006, 7(11): 1896-1903.
[10] 严密, 李晓东, 陈彤, 等. 垃圾焚烧炉烟气中二恶英指示物研究 [J]. 燃烧科学与技术, 2010, 16(3): 257-261.
YAN Mi, LI Xiaodong, CHEN Tong, et al. Investigation of PCDD/Fs indicators in flue gas from waste incinerators [J]. Journal of Combustion Science and Technology, 2010, 16(3): 257-261.
[11] 高洪才, 倪余文, 张海军, 等. 不同垃圾焚烧设备中二噁英的排放特征和ITEQ指示物的研究 [J]. 环境科学, 2009, 30(5): 1545-1550.
GAO Hongcai, NI Yuwen, ZHANG Haijun, et al. PCDD/F emission characteristics in different waste incineration facilities and evaluation of 23478PeCDF as ITEQ indicator of PCDD/F in flue gases [J]. Environmental Science, 2009, 30(5): 1545-1550.
[12] 徐梦侠. 城市生活垃圾焚烧厂二恶英排放的环境影响研究 [D]. 杭州: 浙江大学, 2009: 51.
XU Mengxia. Environmental impact study on PCDD/F emissions from the municipal solid waste incineration plant [D]. Hangzhou: Zhejiang University, 2009: 51.
[13] RORDORF B F. Prediction of vapor pressures, boiling points and enthalpies of fusion for twentynine halogenated dibenzopdioxins and fiftyfive dibenzofurans by a vapor pressure correlation method [J]. Chemosphere, 1989, 18: 783-788.
[14] MADER B T, PANKOW J F. Vapor pressures of the polychlorinated dibenzodioxins (PCDDs) and the polychlorinated dibenzofurans (PCDFs) [J]. Atmospheric Environment, 2003, 37: 3103-3114. |
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
|
Shared |
|
|
|
|
|
Discussed |
|
|
|
|