Please wait a minute...
J4  2010, Vol. 44 Issue (3): 473-475    DOI: 10.3785/j.issn.1008973X.2010.03.011
能源工程与动力工程     
超流氦中喷射流流场的PIV可视化观察
 金滔1, FUZIER Sylvie2, VAN SCIVER Steven2
1. 浙江大学 制冷与低温研究所,浙江 杭州 310027; 2. 美国国家高磁场实验室,美国 佛罗里达 32310
Observation of jet flow into superfluid helium using particle image velocimetry technique
JIN Tao1, FUZIER Sylvie2, VAN SCIVER Steven2
 全文: PDF  HTML
摘要:

利用粒子成像测速仪(PIV)对射入到超流氦液浴中的喷射流的初始发展阶段进行观察,主要考察了流型和流场分布状况,旨在分析通过喷射流来实现的示踪粒子投放过程的实际效果及其对测量精度的影响情况.超流氦液浴温度为1.8 K,示踪粒子为1.7 μm直径的复合物粒子,高速相机拍摄的相邻照片间隔时间为3 ms.实验中观察到的喷射流具有一抛物线形状的流型,与正常流体中观察到的喷射流具有一定的相似性.速度场分析结果也显示,射流内的速度场分布远不如正常流体中均匀和规律变化,其中存在许多局部的涡旋流.沿着射流方向上速度的波动幅度越来越小,平均速度在行进了约35 mm后降至2 mm/s量级.

Abstract:

The initial development of the jet flow into superfluid helium (He II) bath was observed by particle image velocimetry (PIV), focusing on the flow structure and velocity field inside the jet flow, which could be the basis for the analysis of seeding process with a jet of particlecarrying fluid into He II, since it has decisive influence on the measurement accuracy. The He II bath had a temperature of 1.8 K, the polymer seeding particles had the diameter of 1.7μm, and the time span between two CCD pictures was 3 ms. The observed jet flow in He II had a parabolic flow pattern, similar to that in the normal fluid, however, the velocity field of jet flow was less uniform and regular than the normal fluid and much vortex flow was also found in some local areas. The amplitude of the oscillating velocity decreased along the progressive direction of jet flow and the mean velocity reached at about 2 mm/s after the flow left the nozzle for a distance of 35 mm.

出版日期: 2012-03-20
:  O 512.1  
通讯作者: 金滔(1975—),男,浙江永嘉人,教授,从事低温传热、低温制冷等研究.     E-mail: jintao@zju.edu.cn
作者简介: 金滔(1975—),男,浙江永嘉人,教授,从事低温传热、低温制冷等研究.Email: jintao@zju.edu.cn
服务  
把本文推荐给朋友
加入引用管理器
E-mail Alert
RSS
作者相关文章  

引用本文:

金滔, FUZIER Sylvie, VAN SCIVER Steven. 超流氦中喷射流流场的PIV可视化观察[J]. J4, 2010, 44(3): 473-475.

JIN Tao, FUZIER Sylvie, VAN SCIVER Steven. Observation of jet flow into superfluid helium using particle image velocimetry technique. J4, 2010, 44(3): 473-475.

链接本文:

http://www.zjujournals.com/eng/CN/10.3785/j.issn.1008973X.2010.03.011        http://www.zjujournals.com/eng/CN/Y2010/V44/I3/473