传统控烟设施对空气幕阻烟性能的影响
张晓涛,谭翀,陆愈实
中国地质大学 工程学院,湖北 武汉430074
Influence of traditional smoke control facilities on smoke confinement performance of air curtain
ZHANG Xiao tao, TAN Chong,LU Yu shi
Faculty of Engineering, China University of Geosciences, Wuhan 430074, China
 全文: PDF(1660 KB)   HTML
摘要:

以实际建筑走廊结构为基础,利用火灾动力学模拟软件(FDS)构建数值模型;研究在火灾情况下,机械排烟和挡烟垂壁2种传统控烟设施对空气幕两侧的临界压差、隔热效率以及对于温度和一氧化碳的阻隔性能的影响.实验结果表明,随着排烟口风速的增加,机械排烟对空气幕的临界压差提升不明显,但对隔热效率及温度和一氧化碳的阻隔效果提升显著.挡烟垂壁对空气幕临界压差影响显著.当火灾规模较小时,挡烟垂壁可以提高空气幕隔热效率及温度和一氧化碳的阻隔效果|随着火灾规模的增大,空气幕阻烟性能出现突降,挡烟垂壁此时甚至会降低空气幕的阻烟性能|挡烟垂壁高度越小,性能突降现象出现越早.

Abstract:

The numerical model was constructed by fire dynamic simulator (FDS) software based on actual corridor architectural structure. The influence was analyzed that of traditional smoke control facilities, including mechanical smoke extraction and hung wall, on critical pressure difference, thermal insulation efficiency, confine effect of temperature and carbon monoxide of air curtain under fire condition. The experimental results show that with the increase of smoke exhaust rate, mechanical smoke extraction insignificantly affects the critical pressure, which significantly increases thermal insulation efficiency and the confine effect of temperature and carbon monoxide. The hung wall obviously affects the critical pressure of air curtain. The thermal insulation efficiency and confine effect of temperature and carbon monoxide of air curtain is obviously promoted under small-scale fire. However, with the fire scale increasing, sudden drop in performance of air curtain happens; even the hung wall would decrease the performance of air curtain. The ealier the sudden drop in performance appears, the lower the height of hung wall is.

出版日期: 2016-09-22
:  X 928.7  
基金资助:

国家自然科学基金资助项目(61202197).

通讯作者: 陆愈实,男,教授. ORCID: 0000-0002-1083-6309.     E-mail: cuglys@foxmail.com
作者简介: 张晓涛(1987-),男,博士生,从事安全仿真与阻烟研究. ORCID: 0000-0003-1667-1012. E-mail:smiletao@163.com
服务  
把本文推荐给朋友
加入引用管理器
E-mail Alert
RSS
作者相关文章  

引用本文:

张晓涛,谭翀,陆愈实. 传统控烟设施对空气幕阻烟性能的影响[J]. 浙江大学学报(工学版), 10.3785/j.issn.1008-973X.2016.09.14.

ZHANG Xiao tao, TAN Chong,LU Yu shi. Influence of traditional smoke control facilities on smoke confinement performance of air curtain. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 10.3785/j.issn.1008-973X.2016.09.14.

链接本文:

http://www.zjujournals.com/eng/CN/10.3785/j.issn.1008-973X.2016.09.14        http://www.zjujournals.com/eng/CN/Y2016/V50/I9/1738

[1] The Skyscraper Centre. The global tall building database of the CTBUH [EB/OL]. [20120405]. http:∥skyscrapercenter.com.
[2] 杨云春,何嘉鹏. 高层建筑火灾中烟气组合控制设置参数的研究 [J]. 安全与环境学报. 2012,12(2): 201-204.
YANG Yunchun, HE Jiapeng. Study of highrise building fire composite parameters firesmoke control models [J]. Journal of Safety and Environment. 2012, 12(2): 201-204.
[3] HIETANIEMI J, KALLONEN R, MIKKOLA E. Burning characteristics of selected substances: production of heat, smoke and chemical species [J]. Fire and Materials, 1999,23(4):171-185.
[4] HU L H, ZHOU J W, HUO R, et al. Confinement of fireinduced smoke and carbon monoxide transportation by air curtain in channels [J]. Journal of Hazardous Materials, 2008, 156(1/3): 327-334.
[5] LUO N, LI A, GAO R, et al. An experiment and simulation of smoke confinement and exhaust efficiency utilizing a modified opposite doublejet air curtain [J]. Safety Science, 2013, 55: 1725.
[6] LUO N, LI A, GAO R, et al. An experiment and simulation of smoke confinement utilizing an air curtain [J]. Safety Science, 2013, 59: 10-18.
[7] GAO R, LI A, LEI W, et al. Study of a proposed tunnel evacuation passageway formed by oppositedouble air curtain ventilation [J]. Safety Science, 2012, 50(7): 1549-1557.
[8] HU L H, ZHOU J W, HUO R, et al. Confinement of fireinduced smoke and carbon monoxide transportation by air curtain in channels [J]. Journal of Hazardous Materials, 2008, 156(1/3): 327-334.
[9] 陈珊珊,蒋勇,邱榕. 某商铺火灾热和烟气危害性数值研究 [J]. 哈尔滨工程大学学报, 2012, 33(9): 1097-1103.
CHEN Shanshan,JIANG Yong,QIU Rong. Numerical investigation on the hazard of heat and smoke in a store fire [J]. Journal of Harbin Engineering University, 2012, 33(9): 1097-1103.
[10] 李国能,周昊,凌忠钱,等. 标准火灾测试房间温度场和速度场的大涡模拟 [J]. 浙江大学学报:工学版,2006, 40(2): 294-297.
LI Guoneng, ZHOU Hao, LING Zhongqian, et al. Large eddy simulation of temperature field and velocity field in standard fire test room [J]. Journal of Zhejiang University: Engineering Science, 2006,40(2): 294-297.
[11] NIU H, QIAO C, AN J, et al. Experimental study and numerical simulation of spread law for fire on tunnel [J]. Journal of Central South University, 2015, 22(2): 701-706.
[12] 李静娴,何嘉鹏,许小磊.高层建筑走廊排烟口与挡烟垂壁组合控制烟气的研究[J].建筑科学,2011,27(2): 97-101.
LI Jingxian, HE Jiapeng, XU Xiaolei. Research on smoke control by combination of corridor smoke outlet and smoke retaining screen in highrise buildings [J]. Building Science, 2011,27(2): 97-101.
[13] 祝实,霍然,胡隆华,等.网格划分及开口处计算区域延展对FDS模拟结果的影响 [J]. 安全与环境科学, 2008,8(4):131-134.
ZHU Shi, HUO Ran, HU Longhua, et al. Influence of mesh grid and computational domain on FDS simulation [J]. Journal of Safety and Environment, 2008,8(4):131-134.
[14] ZHANG W, HAMER A, KLASSEN M, et al. Turbulence statistics in a fire room model by large eddy simulation [J]. Fire Safety Journal. 2002, 37(8): 721-752.
[15] 谢晶,缪晨,杜子峥,等.冷库空气幕性能数值模拟与参数优化 [J]. 农业机械学报, 2014,45(7): 189-195.
XIE Jing, MIAO Chen, DU Zizheng, et al. Numerical simulation and parameter optimization on performance of air curtain in cold stores [J]. Transactions of the Chinese Society for Agricultural Machinery, 2014, 45(7): 189-195.
[16] 杨彦宾.热压和风压作用下冷库大门空气幕性能的数值研究 [D]. 西安: 西安建筑科技大学,2009.
YANG Yanbin. Numerical study of the air curtain performance of a cold store with wind and thermal pressures [D].Xi’an: Xi’an University of Architecture and Technology,2009.
[17] FOSTER A M, SWAIN M J, BARRETT R, et al. Effectiveness and optimum jet velocity for a plane jet air curtain used to restrict cold room infiltration [J]. International Journal of Refrigeration. 2006, 29(5): 692-699.
[18] 张培红,王增欣.建筑消防[M].北京:机械工业出版社,2008:84-85.
[19] 中华人民共和国公安部.中华人民共和国安全行业标准——挡烟垂壁: GA5332012 [S].北京:中国标准出版社,2012.
[20] WANG L L, ZHONG Z. An approach to determine infiltration characteristics of building entrance equipped with air curtains [J]. Energy and Buildings, 2014, 75: 312-320.
[21] GONCALVES J C, COSTA J J, FIGUEIREDO A R, et al. CFD modelling of aerodynamic sealing by vertical and horizontal air curtains [J]. Energy and Buildings, 2012, 52: 153-160.

No related articles found!