Please wait a minute...
J4  2013, Vol. 47 Issue (6): 1081-1087    DOI: 10.3785/j.issn.1008-973X.2013.06.021
土木工程     
设置非等截面TLCD高层建筑在风荷载作用下减振分析
钟振宇1,2, 楼文娟1
1.浙江大学 建筑工程学院, 浙江 杭州 310058 2.浙江工业职业技术学院 建筑工程学院,浙江 绍兴 312000
Vibration reduction of high-rise buildings with converted TLCD acted by wind load
ZHONG Zhen-yu1,2, LOU Wen-juan1
1. College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, China;
2. Faculty of Civil Engineering and Architecture, Zhejiang Industry Polytechnic College, Shaoxing 312000,China  
 全文: PDF  HTML
摘要:

为了分析非等截面液柱式调谐阻尼器(TLCD)在高层建筑上对脉动风荷载减振的有效性,采用随机振动理论计算结构响应来获得分析数据.建立设有非等截面TLCD高层结构的运动方程,给出变截面TLCD阻尼等效线性化后的主结构传递函数封闭解,分析系统各参数变化对减振效果的影响,并进行优化分析.结果表明:水箱液体质量和结构一阶广义质量的比值越大,减振效果越好,横竖管的长度比也有同样规律|但随着水头损失系数和竖横管面积比的增长使减振效果先增后减.一般而言TLCD频率和主结构基频接近时能达到最优减振率.在实际应用中建议将TLCD安装在轻柔和小阻尼的结构上以获得理想的效果.

Abstract:

In order to analyze the vibration reduction availability of the converted tuned liquid column damper( TLCD) installed on high-rise buildings acted by fluctuating wind load, random vibration theory was used to calculate the structure response to get analytical data. The dynamic equations of high-rise building with converted TLCD were established, and the closed form solution of transfer function about the structure was obtained by linearization of the damping item of the converted TLCD. The parameters of the converted TLCD and the structure were analyzed and optimized for vibration reduction. The results show that the damping effect increases with the ratio of mass of liquid in tank and first order generalized mass of structure. The ratio of length between vertical pipe and horizontal pipe has the same trend. But the damping effect is changed from increasing to decreasing with the ratio of pipes’ section area and the head loss coefficient increasing. In general, the optimal solution can be obtained as the frequency of the TLCD is close to fundamental frequency of the structure. It is suggested to install converted TLCD on slender high-rise buildings with little inherent damping to reach perfect effect.

出版日期: 2013-11-22
:  TU 311.3  
基金资助:

 国家自然科学基金资助项目(51178424).

通讯作者: 楼文娟,女,教授,博导.     E-mail: louwj@zju.edu.cn
作者简介: 钟振宇(1970—),男,教授,从事结构风工程方面的研究.E-mail:sxzzy11@163.com
服务  
把本文推荐给朋友
加入引用管理器
E-mail Alert
RSS
作者相关文章  

引用本文:

钟振宇, 楼文娟. 设置非等截面TLCD高层建筑在风荷载作用下减振分析[J]. J4, 2013, 47(6): 1081-1087.

ZHONG Zhen-yu, LOU Wen-juan. Vibration reduction of high-rise buildings with converted TLCD acted by wind load. J4, 2013, 47(6): 1081-1087.

链接本文:

http://www.zjujournals.com/eng/CN/10.3785/j.issn.1008-973X.2013.06.021        http://www.zjujournals.com/eng/CN/Y2013/V47/I6/1081

[1] LI H N, YI T H, JING Q Y, et al. Wind-Induced vibration control of dalian international trade mansion by tuned liquid dampers[J]. Mathematical Problems in Engineering, 2012,2012: 1-21.

[2] SAKAI F, TAKAEDA S, TAMAKI T. Tuned liquid column damper-new type device for suppression of building vibration[C]∥Proceeinge International Conference on High-rise Building.Nanjing: [s.n.],1989: 926-931.

[3] WU J C. Experimental calibration and head loss prediction of tuned liquid column damper[J]. Tamkang Journal of Science and Engineering, 2005, 8(4): 319-325.

[4] GAO H,KWOK K C S, SAMALI B. Optimization of tuned liquid column dampers[J]. Engineering Structures, 1997, 19(6): 47486.

[5] YALLA S K, KAREEM A. Optimum absorber parameters for tuned liquid column dampers[J]. Journal of Structural Engineering, 2000, 126(8): 906-915.

[6] BALENDRA T, WANG C M, RAKESH G. Vibration control of various types of buildings using TLCD[J]. Journal of Wind Engineering and Industrial Aerodynamics, 1999,83(1-3): 197-208.

[7] REITERER M, ZIEGLER F. Combined seismic activation of a SDOF-building with a passive TLCD attached[C]∥13th World Conference on Earthquake Engineering. Vancouver, BC, Canada:[s.n.],2004: 1-15.

[8] DEBARMA R, CHAKRABORTY S, GHOSH S K. Optimum design of tuned liquid column dampers under stochastic earthquake load considering uncertain bounded system parameters [J]. International Journal of Mechanical Sciences, 2010, 52(10): 1385-1393.

[9] MIN K W, KIM H S, LEE S H, et al. Performance evaluation of tuned liquid column dampers for response control of a 76-story benchmark building[J]. Engineering Structures, 2005, 27(7): 1101-1112.

[10] 殷永炜,阎石,杨金贤.调频液体柱型阻尼器振动控制参数的再研究[J].沈阳建筑工程学院学报,1999, 15(4): 322-327.

YIN Yong-wei,YAN Shi,YANG Jin-xian. A further study on the parameter of vibration control of tuned liquid column dapm[J]Journal of Shenyang Architecture and Civil Engineering Institute,1999,15(4): 322-327.

[11] FARSHIDIANFAR A, OLIAZADEH P. Vibration control of super tall buildings by tuned liquid column damper [C]∥17th International Congress on Sound and Vibration. Cairo, Egypt:[s.n.],2010: 18.

[12] CHANG C H. Computational fluid dynamics simulation for tuned liquid column dampers in horizontal motion[J]. Wind & Structures , 2011, 14(5): 435-447.

[13] FARSHIDIANFAR A, OLIAZADEH P. Closed form optimal solution of a tuned liquid column damper responding to earthquake[J]. World Academy of Science, Engineering and Technology, 2009, 59: 159-164.

[14] SHUM K M, KWOK K C S, HITCHCOCK P A. Closed-Form optimum liquid column vibration absorber parameters for base-excited damped structures[J]. Advances in Structural Engineering, 2011, 14(3): 489-497.

[1] 殷平,王彤,谢旭. 考虑桥墩轴力变化影响的刚构桥近场地震反应[J]. J4, 2013, 47(11): 1896-1903.
[2] 罗尧治, 丁慧. 波纹表面月牙形悬挑屋盖风荷载特性[J]. J4, 2013, 47(6): 1063-1071.
[3] 徐海巍,余世策,楼文娟. 开孔结构内压传递方程的适用性分析[J]. J4, 2012, 46(5): 811-817.