Please wait a minute...
J4  2012, Vol. 46 Issue (9): 1715-1721    DOI: 10.3785/j.issn.1008-973X.2012.09.026
生物医学工程     
基于集成芯片的细胞生理多参数自动分析仪
吴成雄,蔡华,胡宁,胡朝颖,程功,肖丽丹,余辉,王平
浙江大学 生物传感器国家专业实验室,生物医学工程教育部重点实验室,浙江 杭州 310027
Design of automatic analysis instrument for  cell physiological
multi-parameter detection based on integrated chip
WU Cheng-xiong, CAI Hua, HU Ning, HU Zhao-ying,
CHENG Gong, XIAO Li-dan, YU Hui, WANG Ping
Biosensor National Special Laboratory, Key Laboratory of Biomedical Engineering of
Education Ministry, Zhejiang University, Hangzhou 310027, China
 全文: PDF  HTML
摘要:

为了实现对细胞多个生理参数的同时记录,研制了一台自动分析仪,该仪器采用包含光寻址电位传感器(LAPS)、细胞电阻抗传感器(ECIS)、微电极阵列传感器(MEAS)3种细胞传感器的集成芯片及其检测系统.仪器集成了细胞生长环境控制系统和自动流动分析系统,能够满足多种不同的细胞生理实验需求.相比于以往的细胞生理检测仪器,具有多参数同时检测、多功能、自动灵活的特点.进行了细胞胞外酸化率变化和阿霉素作用下细胞阻抗和电位变化的实验,结果表明:分析仪能够对胞外离子、细胞阻抗、胞外电位进行同步、长时检测,可应用于药物评价、药物筛选等生物医学研究领域.

Abstract:

 An automatic analysis instrument was developed to simultaneously record the multi-physiological parameters of the cells.  The instrument employs an integrated chip which consists of light addressable potentiometric sensor (LAPS), electrical cellsubstrate impedance sensor (ECIS) and microelectrode array sensor (MEAS), three different types of cell-based biosensors, and their detection systems. A cell growth environment control system and an automatic flow analysis system were integrated in the instrument, so it can meet different needs of cell physiology experiments. Compared with previous cell physiology testing instruments, the new instrument comes to be multi-parameter, multi-function, automatic and flexible. An investigation of extracellular acidification rate change and doxorubicin inducing change of cell impedance and extracellular potential was carried out. Result shows that the instrument is capable of monitoring extracellular ions, cell impedance and extracellular potential in synchronous and long-time. Thus it can be used in drug evaluation, drug screening and other areas of biomedical research.

出版日期: 2012-09-01
:  R 318.6  
基金资助:

国家自然科学基金重点资助项目(30627002); 浙江省科技厅国际合作重点资助项目(2010C14006).

通讯作者: 王平,男,教授,博导.     E-mail: cnpwang@zju.edu.cn
作者简介: 吴成雄(1986-)男, 博士生, 从事生物医学工程和生物传感器系统研究.E-mail: yebear@zju.edu.cn
服务  
把本文推荐给朋友
加入引用管理器
E-mail Alert
RSS
作者相关文章  

引用本文:

吴成雄,蔡华,胡宁,胡朝颖,程功,肖丽丹,余辉,王平. 基于集成芯片的细胞生理多参数自动分析仪[J]. J4, 2012, 46(9): 1715-1721.

WU Cheng-xiong, CAI Hua, HU Ning, HU Zhao-ying, CHENG Gong, XIAO Li-dan, YU Hui. Design of automatic analysis instrument for  cell physiological
multi-parameter detection based on integrated chip. J4, 2012, 46(9): 1715-1721.

链接本文:

http://www.zjujournals.com/eng/CN/10.3785/j.issn.1008-973X.2012.09.026        http://www.zjujournals.com/eng/CN/Y2012/V46/I9/1715

[1] PANCRAZIO J J, WHELAN J P, BORKHOLDER D A, et al. Development and application of cellbased biosensors[J]. Annals of Biomedical Engineering, 1999,27(6): 697-711.
[2] MCFADDEN P. Broadband biodetection: Holmes on a chip [J].Science,2002,297(5589): 2075-2976.
[3] XU Gaixia, YE Xuesong, QIN Lifeng, et al. Cellbased biosensors based on lightaddressable potentiometric sensors for single cell monitoring[J].Biosensors & Bioelectronics, 2005, 20(9): 1757-1763.
[4] WU Yicong, WANG Ping, YE Xuesong, et al. Drug evaluation using a novel microphysiometer based on cellbased biosensors[J].Sensors & Actuators B, 2001, 80(3): 215-221.
[5] WU Yicong, WANG Ping, YE Xuesong, et al. A novel microphysiometer based on MLAPS for drug screening[J]. Biosensors & Bioelectronics, 2001,16(4/5): 277-286.
[6] LIU Qingjun, CAI Hua, XU Ying, et al. Detection of heavy metal toxicity using cardiac cellbased biosensor for detection of heavy metal ions[J]. Biosensors and Bioelectronics, 2007,22(12): 3224-3229.
[7] YU Hui, CAI Hua, ZHANG Wei, et al. A novel design of multifunctional integrated cellbased biosensors for simultaneously detecting cell acidification and extracellular potential[J]. Biosensors and Bioelectronics, 2009, 24(5): 1462-1468.
[8] LIU Qingjun, YU Jinjiang, XIAO Lidan, et al. Impedance studies of biobehavior and chemosensitivity of cancer cells by microelectrode arrays[J]. Biosensors and Bioelectronics ,2009,24(5): 1305-1310.
[9] 胡朝颖,刘清君,张远帆,等.细胞阻抗传感器优化设计及其在毒素监测中的应用[J].传感技术学报,2010,23(3): 291-296.
HU Zhaoying, LIU Qingjun, ZHANG Yuanfan, et al. Optimization design of electrical cellsubstrate impedance sensor and application to toxicant monitoring[J]. Chinese Journal of Sensors and Actuators, 2010,23(3): 291-296.
[10] XU Ying, YU Hui, CAI Hua, et al. A novel integrated cellbased biosensor for extracellular electrophysiological monitoring[J].International Journal of Information Acquisition, 2007, 4(3): 193-204.
[11] COLALONGO L, VERZELLESI G. Modeling of LightAddressable Potentiometric Sensors[J]. Electron Devices, 1997,44(11): 2083-2090.
[12] STETT A, EGERT U, GUENTHE E, et al. Biological application of microelectrode arrays in drug discovery and basic research[J]. Anal Bioanal Chem, 2003,377(3): 486-495.
[13] YU Hu, CAI Hua, ZHANG Wei, et al. A novel design of multifunctional integrated cellbased biosensors for simultaneously detecting cell acidification and extracellular potential[J]. Biosens Bioelectron, 2009,24(5): 1462-1468.
[14] BRAAM SR, TERTOOLEN L, VAN DE STOLPE A,et al. Prediction of druginduced cardiotoxicity using human embryonic stem cellderived cardiomyocytes[J]. Stem Cell Res, 2010,4(2): 107-116.
[15] HAFEMAN D G, PARCE J W, MCCONNELL H M. Lightaddressable potentiometric sensor for biochemical systems[J]. Science, 1988,240(4856): 1182-1185.
[16] SINGAL P K, ILISKOVIC N. Doxorubicininduced cardiomyopathy[J].The New England Journal of Medicine,1998,339(13): 900-905.
[17] XI Biao, YU Naichen, WANG Xiaobo, et al. The application of cellbased labelfree technology in drug discovery[J]. Biotechnology,2008,3(4): 484-495.

[1] 程功, 王江容, 吴成雄, 胡宁, 周洁, 王平. 细胞生理多参数自动分析仪的
软件设计及算法分析
[J]. J4, 2012, 46(12): 2285-2292.
[2] 王娟,黄忠朝,刘正春. 基于增强的谱分析和奇异值分解的T波交替检测[J]. J4, 2012, 46(1): 177-181.