生物医学工程 |
|
|
|
|
基于PVC薄膜的汞离子光寻址电位传感器 |
李毅, 张舟娜, 蔡巍, 高小明, 王平 |
浙江大学 生物传感器国家专业实验室,生物医学工程系,浙江 杭州 310027 |
|
Mercury ion selective light addressable potentiometric sensor
based on PVC membrane |
LI Yi, ZHANG Zhou-na, CAI Wei, GAO Xiao-ming, WANG Ping |
Biosensor National Special Laboratory, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China |
引用本文:
李毅, 张舟娜, 蔡巍, 高小明, 王平. 基于PVC薄膜的汞离子光寻址电位传感器[J]. J4, 2010, 44(6): 1231-1236.
LI Yi, ZHANG Zhou-Na, CA Wei, GAO Xiao-Meng, WANG Beng. Mercury ion selective light addressable potentiometric sensor
based on PVC membrane. J4, 2010, 44(6): 1231-1236.
链接本文:
http://www.zjujournals.com/eng/CN/10.3785/j.issn.1008-973X.2010.06.033
或
http://www.zjujournals.com/eng/CN/Y2010/V44/I6/1231
|
[1] 韦进宝,钱沙华,环境分析化学[M].北京:化学工业出版社,2002.
[2] 樊邦棠,环境化学[M].杭州:浙江大学出版社,1991: 15361551.
[3] YANTASEE W, LIN Y, ZEMANIAN T S, et al. Voltammetric detection of lead (Ⅱ) and mercury (Ⅱ) using a carbon paste electrode modified with thiol selfassembled monolayer on mesoporous silica (SAMMS)[J]. The Analyst, 2003,128(5): 467472.
[4] ERMOLENKO Y, YOSHINOBU T, MOURZINA Y, et al. Laserscanned silicon transducer (LSST) as a multisensor system[J]. Sensors & Actuators: B. Chemical, 2004,103(1/2): 457462.
[5] ERMOLENKO Y, YOSHINOBU T, MOURZINA Y, et al. Photocurable membranes for ionselective lightaddressable potentiometric sensor[J]. Sensors & Actuators: B. Chemical, 2002,85(1/2): 7985.
[6] ERMOLENKO Y, YOSHINOBU T, MOURZINA Y, et al. The double K+/Ca2+ sensor based on laser scanned silicon transducer (LSST) for multicomponent analysis[J]. Talanta, 2003, 59(4): 785795.
[7] ERMOLENKO Y E, YOSHINOBU T, MOURZINA Y G, et al. Anionselective lightaddressable potentiometric sensors (LAPS) for the determination of nitrate and sulphate ions[J]. Sensors & Actuators: B. Chemical, 2003,91(1/3): 3238.
[8] GUPTA V K, SINGH A K, AL KHAYAT M, et al. Neutral carriers based polymeric membrane electrodes for selective determination of mercury (Ⅱ)[J]. Analytica Chimica Acta, 2007,590(1): 8190.
[9] 王娟,张长瑞,冯坚.三甲基氯硅烷对纳米多孔二氧化硅薄膜的修饰[J].物理化学学报,2004,20(12): 13991403.
WANG Juan, ZHANG Changrui, FENG Jian. Modification of Nanoporous Silica Film by Trimethylchlorosilane[J]. Acta PhysicoChimica Sinica,2004,20(12): 13991403.
[10] 贾芸芳,牛文成,张福海,等.EIS型半导体生化传感器EI界面势的理论模拟[J].半导体学报,2005,26(11): 21962201.
JIA Yunfang, NIU Wencheng, ZHANG Fuhai, et al. Simulation of EIInterface voltage in an EIStype semiconductor biochemical sensor[J]. Chinese Journal of Semiconductors,2005,26(11): 21962201.
[11] De MARCO R, SHACKLETON J. Calibration of the Hg chalcogenide glass membrane ionselective electrode in seawater media[J]. Talanta, 1999,49(2): 385391.
[12] RUDNITSKAYA A, LEGIN A, SELEZNEV B, et al. Detection of ultralow activities of heavy metal ions by an array of potentiometric chemical sensors[J]. Microchimica Acta,2008,163(1): 7180. |
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
|
Shared |
|
|
|
|
|
Discussed |
|
|
|
|