摘要:

通过不同浓度溶液的试验,对一种新型聚氯乙稀(PVC)薄膜汞离子敏感光寻址电位传感器进行了研究,PVC薄膜中的敏感物为5amino1,3,4thiadiazole2thiol.采用硅烷化反应对光寻址电位传感器进行表面修饰,硅烷化前后的器件对单位pH(氢离子)的灵敏度分别为每67.299 mV和4.999 6 mV,线性相关系数分别为0.983 1和0.987 7.PVC膜成聚后,该传感器对汞离子有选择性的电位响应特性,显示了良好的重复性和稳定性,单位pHg(汞离子)的灵敏度为15.381 mV,线性相关系数为0.962 9,对其他离子的抑制比大于4.实验得到的检出下限为1.57 μg/L,响应时间为2~4 s,适用pH范围为3~6.

Abstract:

A novel polyvinyl chloride(PVC) thinfilm light addressable potentiometric sensor sensitive to mercury (Ⅱ) ion was tested by gradient concentrations. PVC matrix with 5amino1,3,4thiadiazole2thiol was prepared and used as target material. Light addressable potentiometric sensor(LAPS) sensor was chemically modified by silanization. The sensitivities before and after the reaction are 67.299 mV per pH and 4.999 6 mV per pH, the linear correlations are 0.983 1 and 0.987 7, respectively. Once PVC membrane was deposited, Hg2+ sensitive LAPS exhibits a good stability and repetition. The sensitivity of the potentiometric response shows the slope of 15.381 mV per pHg. The detection limit of the sensor was 1.57 μg/L. The response time maintained 24 s, and the application range of pH was located between 36.

出版日期: 2010-07-16
:     
基金资助:

国家“973”重点基础研究发展计划资助项目(2009CB320303)

通讯作者: 王平,男,教授,博导.     E-mail: cnpwang@zju.edu.cn
作者简介: 李毅(1985—)男,天津人,硕士生,从事生物医学和生物化学传感器模拟仿真和器件设计的研究.E-mail:plumcore@mail.com
服务  
把本文推荐给朋友
加入引用管理器
E-mail Alert
RSS
作者相关文章  

引用本文:

李毅, 张舟娜, 蔡巍, 高小明, 王平. 基于PVC薄膜的汞离子光寻址电位传感器[J]. J4, 2010, 44(6): 1231-1236.

LI Yi, ZHANG Zhou-Na, CA Wei, GAO Xiao-Meng, WANG Beng. Mercury ion selective light addressable potentiometric sensor based on PVC membrane. J4, 2010, 44(6): 1231-1236.

链接本文:

http://www.zjujournals.com/eng/CN/10.3785/j.issn.1008-973X.2010.06.033        http://www.zjujournals.com/eng/CN/Y2010/V44/I6/1231

[1] 韦进宝,钱沙华,环境分析化学[M].北京:化学工业出版社,2002.

 

[2] 樊邦棠,环境化学[M].杭州:浙江大学出版社,1991: 15361551.

 

[3] YANTASEE W, LIN Y, ZEMANIAN T S, et al. Voltammetric detection of lead (Ⅱ) and mercury (Ⅱ) using a carbon paste electrode modified with thiol selfassembled monolayer on mesoporous silica (SAMMS)[J]. The Analyst, 2003,128(5): 467472.

[4] ERMOLENKO Y, YOSHINOBU T, MOURZINA Y, et al. Laserscanned silicon transducer (LSST) as a multisensor system[J]. Sensors & Actuators: B. Chemical, 2004,103(1/2): 457462.

[5] ERMOLENKO Y, YOSHINOBU T, MOURZINA Y, et al. Photocurable membranes for ionselective lightaddressable potentiometric sensor[J]. Sensors & Actuators: B. Chemical, 2002,85(1/2): 7985.

[6] ERMOLENKO Y, YOSHINOBU T, MOURZINA Y, et al. The double K+/Ca2+ sensor based on laser scanned silicon transducer (LSST) for multicomponent analysis[J]. Talanta, 2003, 59(4): 785795.

[7] ERMOLENKO Y E, YOSHINOBU T, MOURZINA Y G, et al. Anionselective lightaddressable potentiometric sensors (LAPS) for the determination of nitrate and sulphate ions[J]. Sensors & Actuators: B. Chemical, 2003,91(1/3): 3238.

[8] GUPTA V K, SINGH A K, AL KHAYAT M, et al. Neutral carriers based polymeric membrane electrodes for selective determination of mercury (Ⅱ)[J]. Analytica Chimica Acta, 2007,590(1): 8190.

[9] 王娟,张长瑞,冯坚.三甲基氯硅烷对纳米多孔二氧化硅薄膜的修饰[J].物理化学学报,2004,20(12): 13991403.

WANG Juan, ZHANG Changrui, FENG Jian. Modification of Nanoporous Silica Film by Trimethylchlorosilane[J]. Acta PhysicoChimica Sinica,2004,20(12): 13991403.

[10] 贾芸芳,牛文成,张福海,等.EIS型半导体生化传感器EI界面势的理论模拟[J].半导体学报,2005,26(11): 21962201.

JIA Yunfang, NIU Wencheng, ZHANG Fuhai, et al. Simulation of EIInterface voltage in an EIStype semiconductor biochemical sensor[J]. Chinese Journal of Semiconductors,2005,26(11): 21962201.

[11] De MARCO R, SHACKLETON J. Calibration of the Hg chalcogenide glass membrane ionselective electrode in seawater media[J]. Talanta, 1999,49(2): 385391.

[12] RUDNITSKAYA A, LEGIN A, SELEZNEV B, et al. Detection of ultralow activities of heavy metal ions by an array of potentiometric chemical sensors[J]. Microchimica Acta,2008,163(1): 7180.

[1] 宁志华,何乐年,胡志成. 一种高压高可靠性开关电源控制芯片[J]. J4, 2014, 48(3): 377-383.
[2] 李林,陈家旺,顾临怡,王峰. 轴向柱塞泵/马达变量阀配流机构[J]. J4, 2014, 48(1): 29-34.
[3] 陈钊,余锋,陈婷婷. 基于日志结构的闪存均衡回收策略[J]. J4, 2014, 48(1): 92-99.
[4] 蒋湛,姚晓明,林兰芬. 基于特征自适应的本体映射方法[J]. J4, 2014, 48(1): 76-84.
[5] 陈迪仕 ,张宇,李平. 微小型无人直升机地面效应建模[J]. J4, 2014, 48(1): 154-160.
[6] 霍新新,褚金奎,韩冰峰,姚斐.  基于多个压电换能器的接口电路[J]. J4, 2013, 47(11): 2038-2045.
[7] 杨鑫,许端清,杨冰. 基于不规则性的并行计算方法[J]. J4, 2013, 47(11): 2057-2064.
[8] 王玉强,张宽地,陈晓东. 胶黏钢-混凝土组合梁的界面行为数值分析[J]. J4, 2013, 47(9): 1593-1598.
[9] 彭勇,徐小剑. 集料分布对沥青混合料劈裂强度影响数值分析[J]. J4, 2013, 47(7): 1186-1191.
[10] 崔何亮, 张丹, 施斌.  布里渊分布式传感的空间分辨率及标定方法[J]. J4, 2013, 47(7): 1232-1237.
[11] 伍晓榕,裘乐淼,张树有,孙良峰,郭传龙. 模糊语境下的复杂系统关联FMEA方法[J]. J4, 2013, 47(5): 782-789.
[12] 金波,陈诚,李伟. 具有半球形足端的六足机器人步态修正算法[J]. J4, 2013, 47(5): 768-774.
[13] 钟世英, 吴晓君, 蔡武军, 凌道盛, 蒋祝金, 王顺玉. 月面软着陆足垫水平拖曳模型试验装置研制[J]. J4, 2013, 47(3): 465-471.
[14] 袁幸,朱永生,张优云,洪军,祁文昌. 基于正反问题的滚动轴承损伤程度评估[J]. J4, 2012, 46(11): 1960-1967.
[15] 杨飞,朱株,龚小谨,刘济林. 基于三维激光雷达的动态障碍实时检测与跟踪[J]. J4, 2012, 46(9): 1565-1571.