Please wait a minute...
J4  2012, Vol. 46 Issue (2): 366-371    DOI: 10.3785/j.issn.1008-973X.2012.02.029
生物医学工程、光学工程     
集成成像技术的像质评价分析
解静, 刘旭, 李海峰
浙江大学 现代光学仪器国家重点实验室,浙江 杭州310027
The image quality evaluation for integral imaging
XIE Jing, LIU Xu, LI Hai-feng
State Key Laboratory of Modern Optical Instrumentation, Zhejiang University, Hangzhou 310027, China
 全文: PDF 
摘要:

为了研究集成成像非共轭面的成像质量,根据光线追迹原理分析透镜阵列的成像过程,指出三维成像原理并给出不同离焦量下的轴截面成像分辨率;从波动光学角度分析包含离焦波像差的透镜阵列光学传递(OTF),得到集成成像系统的非共轭面调制传递函数(MTF)并指出与单透镜共轭面成像的联系.根据非共轭面分辨率给出符合视觉要求的显示深度计算方法.采用投影仪与菲涅尔透镜搭建显示面积为100×750 mm2的集成成像显示系统,实验结果表明,集成成像轴截面成像分辨率在离焦量增大的情况下迅速下降,非共轭面像质是制约集成成像显示效果的重要因素之一.

关键词: 集成成像非共轭成像调制传递函数(MTF)分辨率    
Abstract:

To analyze the quality of defocused image for integral imaging, the process of 3D display for integral imaging was explained by ray tracing principle, and the resolution of defocused image was given out. In the views of wave optics, the optical transform function (OTF) with wavefront aberration was analyzed, the modulation transfer function (MTF) for defocused image was given out, and the relation with single lens was illustrated. According to resolution of defocused image, a practical calculation method of display depth is given out. Integral imaging system whose area was 100×750 mm2 was built up by fresnel lens and the projector. From experiment results it shows that resolution becomes worse when the defocus value becomes bigger, the quality of defocused image is one of the important factors of the integral imaging.

Key words: integral imaging    defocus imaging    modulation transfer function (MTF)    resolution
出版日期: 2012-03-02
:  TN 27  
基金资助:

国家“973”重点基础研究发展计划资助项目(2009CB320803).

通讯作者: 刘旭,男,教授,博导.     E-mail: liuxu@zju.edu.cn
作者简介: 解静(1985—),女,硕士,主要从事三维立体显示技术方面的研究.E-mail: xie0jing0@126.com
服务  
把本文推荐给朋友
加入引用管理器
E-mail Alert
RSS
作者相关文章  

引用本文:

解静, 刘旭, 李海峰. 集成成像技术的像质评价分析[J]. J4, 2012, 46(2): 366-371.

XIE Jing, LIU Xu, LI Hai-feng. The image quality evaluation for integral imaging. J4, 2012, 46(2): 366-371.

链接本文:

http://www.zjujournals.com/xueshu/eng/CN/10.3785/j.issn.1008-973X.2012.02.029        http://www.zjujournals.com/xueshu/eng/CN/Y2012/V46/I2/366

[1] LIPPMANN G. La photographic intergrale [J]. Comptes Rendus de I Académie des Sciences,1908,146: 446-451.
[2]林远芳,张晓洁,徐韡,等.体显示中点阵扫描模式对体像素方位的影响[J].浙江大学学报:工学版, 2005,39 (8): 1273-1276.
LIN Yuanfang, ZHANG Xiaojie, XU Wei, et al. Effect of dot matrix scanning mode on voxel orientation in volumetric display system [J]. Journal of Zhejiang University: Engineering Science, 2005, 39 (8): 1273-1276.
[3] MIN S, KIM J, LEE B. New characteristic equation of three dimensional integral imaging system and its applications [J]. Japanese Journal of Applied Physics, 2005, 44(2): 71-72.
[4] CHOI H, KIM Y, PARK J, et al. Improved analysis on the viewing angle of integral imaging [J]. Applied Optics, 2005, 44(12): 2311-2314.
[5] STERN A, AVIDI B. Shannon number and information capacity of three dimensional integral imaging [J]. Journal of the Optical Society of America, 2004, 21(9): 1602-1605.
[6] HONG J, PARK J, KIM J. Analysis of image depth in integral imaging and its enhancement by correction to elemental images [C]∥ Proceedings of the SPIE. Denver: SPIE, 2004, 5524: 387-395.
[7] Wang Xiaorui, Bu Qingfeng, Zhang Dongyang. Method for quantifying the effects of aliasing on the viewing resolution of integral images [J]. Optics Letters, 2009, 34(21): 3382-3384.
[8] PARK J, HONG K, LEE B. Recent progress in three dimensional information processing based on integral imaging [J]. Applied Optics, 2009, 48(34): 77-94.
[9] KIM J, PARK G, KIM Y, et al. Elimination of image discontinuity in integral floating display by using adaptive image mapping [J]. Applied Optics, 2009, 48(34): 176-184.
[10] JIN F and JANG J. Effects of device resolution on three dimensional integral imaging [J]. Optics Letters, 2004, 29(12): 1345-1347.
[11] OKANO F, ARAI J, KAWAKITA M. Wave optical analysis of integral method for three dimensional images [J]. Optics Letters, 2007, 32(4): 364-366.
[12] ARAI J, HOSHINO H, OKUI M. Effects of focusing on the resolution characteristics of integral photography [J]. Journal of the Optical Society of America, 2003, 20(6): 996-1004.
[13] GOOGMAN J. Introduction to fourier optics [M]. New York: McGrawHill, 1996.
[14] MAIR C, GOOGMAN C. Diffraction limited depth from defocus [J]. Electronics Letters, 2000, 36(24): 2012-2013.
[15] 麦伟麟.光学传递函数及其数理基础[M].北京: 国防工业出版社, 1979: 338-342.

[1] 叶肖伟, 刘坦, 董传智, 陈斌. 基于卡尔曼滤波和中性轴位置的结构损伤识别[J]. 浙江大学学报(工学版), 2017, 51(10): 2012-2018.
[2] 吴施伟,吴海腾,金浩然,杨克己,武二永. 聚焦探头水浸检测下的频域合成孔径聚焦技术[J]. 浙江大学学报(工学版), 2015, 49(1): 110-115.
[3] 李志娟, 冯远静, 牛延棚, 李蓉, 叶峰. 基于离散球面反卷积的白质纤维重构算法[J]. 浙江大学学报(工学版), 2014, 48(6): 987-993.
[4] 崔何亮, 张丹, 施斌.  布里渊分布式传感的空间分辨率及标定方法[J]. J4, 2013, 47(7): 1232-1237.
[5] 胡根生,鲍文霞,梁栋,张为. 基于SVR和贝叶斯方法的全色与多光谱图像融合[J]. J4, 2013, 47(7): 1258-1266.
[6] 乔龙学, 王伟刚, 何姗, 鲁阳. 双悬臂梁直径测量传感器性能分析[J]. J4, 2012, 46(6): 1060-1066.
[7] 沈洪垒,田 钢,石战结,张宣堂,丛志国,闫立志. 压电匹配滤波技术在塔巴庙地区的应用[J]. J4, 2012, 46(3): 560-567.
[8] 王磊, 孟濬. 基于wavelet的一类脉搏信号疾病特征量化分析[J]. J4, 2012, 46(10): 1866-1871.
[9] 朱正为,周建江. 基于MMSE-T的合成孔径雷达图像超分辨率重建[J]. J4, 2011, 45(9): 1576-1581.
[10] 苏茂鑫, 李术才, 薛翊国, 邱道宏. 基于反褶积的探地雷达高分辨率处理方法[J]. J4, 2010, 44(6): 1201-1206.
[11] 徐亮, 陈心昭, 毕传兴, 等. 近场声全息分辨率增强的正交球面波插值方法[J]. J4, 2009, 43(10): 1808-1811.
[12] 杨克己, 方文平, 黄一春, 等. 一种应用于超声无损检测的广谱反卷积技术研究[J]. J4, 2009, 43(10): 1766-1771.
[13] 高培生 陈新建 吴为麟 宋保明. 二维表示的电能质量故障数据压缩[J]. J4, 2008, 42(4): 686-690.
[14] 王凌 徐之海 冯华君 李奇. 线阵推扫式CCD亚像元成像的列向动态调制传递函数[J]. J4, 2008, 42(2): 317-320.
[15] 沈会良 牟同升 黄丹丹 杨冬晓 李志能. 数字光处理投影系统成像质量测量方法[J]. J4, 2007, 41(9): 1527-1531.