Please wait a minute...
JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE)
    
Research on characteristics and applications of novel all-solid-state electrode in two-electrode system
LI Ya-zhuo1, WANG Guang-wei2, JIN Jian-yu2, CAI Pei-jun1, WANG Xiao-ping1
1. State Key Laboratory for Modern Optical Instrumentation,Zhejiang University,Hangzhou 310027,China;2. Philips Research Asia – Shanghai, Lane 888, Tianlin Road, Shanghai, 200233, China
Download:   PDF(1504KB) HTML
Export: BibTeX | EndNote (RIS)      

Abstract  

In order to enhance the stability of two-electrode system detecting instrument, active carbon (AC) electrode with large surface area had been used as all-solid-state counter electrode in novel detecting instrument. After investigating the super capacitance property and potential stability of AC electrode, it had been served as counter electrode, together with Pt and glassy carbon working electrode to form a two-electrode water quality detecting instrument for hydrogen peroxide and lead ion determination, respectively. The detection results indicate that, the sensitivity, detection limit and detection range of this detecting instrument are all reach the detecting performance of conventional three-electrode system. Active carbon is of advantages as potential stable, chemical inertness, low cost, ease of use and maintenance, which makes the novel two-electrode water quality detecting instrument simpler with a high reliability and a promising application prospect.



Published: 01 August 2014
CLC:  TH 832  
Cite this article:

LI Ya-zhuo, WANG Guang-wei, JIN Jian-yu, CAI Pei-jun, WANG Xiao-ping. Research on characteristics and applications of novel all-solid-state electrode in two-electrode system. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 2014, 48(8): 1517-1521.

URL:

http://www.zjujournals.com/eng/10.3785/j.issn.1008-973X.2014.08.023     OR     http://www.zjujournals.com/eng/Y2014/V48/I8/1517


两电极体系新型全固态电极特性分析与应用

为提高两电极体系检测仪器的稳定性,采用具有极大比表面积的活性炭电极作为全固态对电极构成新型两电极体系检测仪器,并对该仪器特性进行一系列分析.研究考察活性炭电极的超级电容特性和电极电位稳定性,以铂、玻碳电极为工作电极,新型全固态活性炭电极为对电极,构建两电极体系水质检测仪器,并应用于水体中双氧水与铅离子的检测.结果表明,该检测仪器的灵敏度、检出限、检测范围均取得了与三电极体系类似的检测结果.采用活性炭对电极的固态电极具有电位稳定、化学惰性、价格低、易于小型化、易于使用和维护等优点,使构建的两电极水质检测仪器结构简单、可靠性高,具有较好应用前景.

[1] WINQUIST F, BJORKLUND R, KRANTZ-RULCKER C, et al. An electronic tongue in the dairy industry [J]. Sensors and Actuators B: Chemical, 2005, 111: 299-304.
[2] GHILANE J, HAPIOT P, and BARD A J. Metal/polypyrrole quasi-reference electrode for voltammetry in nonaqueous and aqueous solutions [J]. Analytical chemistry, 2006, 78(19): 6868-6872.
[3] LEE H J, LAGGER G, PEREIRA C M, et al. Amperometric tape ion sensors for cadmium (II) ion analysis [J]. Talanta, 2009, 78(1): 66-70.
[4] WINQUIST F, KRANTZ-RULCKER C, OLSSON T, et al. Measurements of cadmium in soil extracts using multi-variate data analysis and electrochemical sensors [J]. Precision Agriculture, 2009, 10(3): 231-246.
[5] 魏佳莉, 章颖强, 李雅卓,等. 基于两电极体系的水质检测分析平台设计 [J]. 传感技术学报. 2012, 25(10): 1327-1332.
WEI Jia-li, ZHANG Ying-qiang, LI Ya-zhuo, et al. The design of a inspection and analysis platform of aqueous solution based on two-electrode system [J]. Chinese journal of sensors and actuators, 2012, 25(10): 1327-1332.
[6] WINQUIST F, OLSSON T, and ERIKSSON M. Multicomponent analysis of drinking water by a voltammetric electronic tongue [J]. Analytica chimica acta, 2011, 683(2): 192-197.
[7] RUCH P W, CERICOLA D, HAHN M, et al. On the use of activated carbon as a quasi-reference electrode in non-aqueous electrolyte solutions [J]. Journal of Electroanalytical Chemistry, 2009, 636(1): 128-131.
[8] 甘琦,周昕,赵斌元,等.成型活性炭的制备研究进展[J].材料导报.2006, 20(1): 61-63.
GAN Qi, ZHOU Xin, ZHAO Bing-yuan, et al. The advance of research on formed activated carbon preparation [J]. Material Review, 2006, 20(1): 61-63.
[9] PELL W G, CONWAY B E. Voltammetry at a de Levie brush electrode as a model for electrochemical supercapacitor behaviour [J]. Journal of Electroanalytical Chemistry, 2001, 500(1): 121-133.
[10] TAKATSY A, CSOKA B, NAGY L, et al. Periodically interrupted amperometry at membrane coated electrodes: A simplified pulsed amperometry [J]. Talanta, 2006, 69(1): 281-285.
[11] 于春梅 and 顾海鹰. 电化学预处理玻碳电极示差脉冲伏安法测定水中痕量铅 [J]. 理化检验:化学分册. 2010, 46(5): 525-527.
YU Chun-mei, GU Hai-ying. Determination of trace amount of lead in water by differential pulse voltammetry with chemically pretreated glassy carbon electrode [J]. Physical Testing and Chemical Analysis Part B: Chemical Analysis, 2010, 46(5): 525-527.

No related articles found!