Algorithm of optimal phasor measurement unit placement  considering multiconstraints
CHEN Xiaogang1,2, YU Hao1, WANG Bo2, JIANG Zhengwei3, JIANG Quanyuan2,
GUO Chuangxin2,CAO Yijia2
1. Hangzhou Electric Power Bureau, Hangzhou 310009,China; 2. College of Electrical Engineering, Zhejiang University,
Hangzhou 310027,China; 3.Zhejiang Electric Power Dispatching and Communication Center, Hangzhou 310007,China
Download:   PDF(0KB) HTML
Export: BibTeX | EndNote (RIS)      

Abstract  

Based on the improved simulated annealed method, an algorithm of optimal phasor measurement unit (PMU) placement considering multiconstraints was proposed. The minimal PMU placement can be achieved when multiconstraints are meet. The multiconstraints include: considering the installed PMUs, monitoring the critical infrastructures and maintaining the full observability of wide area measurement system (WAMS)when certain transmission lines are out of service. A practical application of this method in a provincial power grid showed that this method has good adaptability when considering the multiphase PMU installation and the topology change.



Published: 20 March 2012
CLC:  TM734  
Cite this article:

CHEN Xiao-Gang, XU Gao, WANG Bei, JIANG Zheng-Wei, JIANG Quan-Yuan, GUO Chuang-Xin, CAO Yi-Jia. Algorithm of optimal phasor measurement unit placement  considering multiconstraints. J4, 2010, 44(3): 539-543.

URL:

http://www.zjujournals.com/eng/10.3785/j.issn.1008-973X.2010.03.023     OR     http://www.zjujournals.com/eng/Y2010/V44/I3/539


满足多种约束条件的最优PMU配置方法

针对现有相量测量单元(PMU)最优配置方法无法同时考虑多种约束条件的问题,提出了一种基于改进模拟退火算法的满足多种约束条件的最优PMU配置方法.该方法能够在同时考虑已安装PMU、对电网中的重要环节进行直接监测及特定输电线路退出运行的情况下,广域测量系统(WAMS)仍然保持对全网完全可观测等多种约束条件的同时,以最少数量的PMU实现对整个电网的完全可观测.给出了该方法在国内某省级电网的应用实例.实际应用显示,该方法在需要考虑分阶段安装PMU及电网拓扑改变的情况时具有良好的适应性.

[1] 宋晓娜,毕天姝,吴京涛.基于WAMS的电网扰动识别方法[J].电力系统自动化,2006, 30(5): 2428.
SONG Xiaona, BI Tianshu, WU Jingtao. Study on WAMS based power system disturbance identifying method [J]. Automation of Electric Power Systems, 2006, 30(5): 2428.
[2] 赵金利,余贻鑫.基于本地相量测量的电压失稳指标工作条件分析[J].电力系统自动化,2006, 30(24): 110.
ZHAO Jinli, YU Yixin. Conditions of appling voltage instability predictor (VIP) based on local measurements [J]. Automation of Electric Power Systems, 2006, 30(24): 110.
[3] 黄莹,徐政.基于同步相量测量单元的直流附加控制器研究[J].中国电机工程学报,2004,24(9): 712.
HUANG Ying, XU Zheng. HVDC supplementary controller based on synchronized phasor measurement units[J]. Proceedings of the CSEE, 2004, 24(9): 712.
[4] 谢小荣,李红军,吴京涛.同步相量技术应用于电力系统暂态稳定性控制的可行性分析[J].电网技术,2004, 28(1): 1014.
XIE Xiaorong, LI Hongjun, WU Jingtao. Feasibility study on using synchrophasor technology for power system transient stability control[J]. Power System Technology, 2004, 28(1): 1014.
[5] 彭疆南,孙元章,王海风.考虑系统完全可观测性的PMU最优配置方法[J].电力系统自动化,2003, 27(4): 1016.
PENG Jiangnan, SUN Yuanzhang, WANG Haifeng. An optimal PMU placement algorithm for full network observability[J].Automation of Electric Power Systems, 2003, 27(4): 1016.
[6] BALDWIN T L, MILI L. Power system observability with minimal phasor measurement placement[J]. IEEE Trans on Power Systems, 1993, 8(2): 707715.
[7] 蔡田田,艾芊.电力系统中PMU最优配置的研究[J].电网技术,2006,30(13): 3237.
CAI Tiantian, AI Qian. Research on optimal PMU placement in power systems[J]. Power System Technology, 2006, 30(13): 3237.
[8] MARIN F J, GARCIA L. Genetic algorithms for optimal placement of phasor measurement units in electrical networks [J]. Electronics Letters, 2003, 39(19): 14031405.
[9] 卢志刚,郝玉山,康庆平.启发式遗传算法在优化电力系统相角测量装置安装地点中的应用[J].电网技术,1998, 22(8): 1417.
LU Zhigang, HAO Yushan, KANG Qingping. Heuristic genetic algorithm in minimal phasor meaurement unit placement for electirc power system[J]. Power System Technology, 1998, 22(8): 1417.
[10] CHEN Jian, ALI Abur. Improved bad data processing via strategic placement of PMUs [C] // Proceedings of IEEE Power Engineering Society General Meeting. Tampa: IEEE, 2005, 1: 509 513
[11] 王克英,穆钢,陈学允.计及PMU的状态估计精度分析及配置研究[J].中国电机工程学报,2001,21(8): 2933.
WANG Keying, MU Gang, CHEN Xueyun. Precision on improvement and PMU placement studies on state estimation of a hybrid measurement system with PMUs [J]. Proceedings of the CSEE, 2001, 21(8): 2933.
[12] LIEN K P, LIU C W, YU C S, et al. Transmission network fault location observability with minimal PMU placement [J]. IEEE Trans on Power Delivery, 2006, 21(3): 11281136.
[13] USCanada Power Outage Task force. Final report on the August 14th 2003 blackout in the United States and Canada [EB/OL].\
[20040401\]. http://www.nerc.com/~filez/blackout. html.

No related articles found!