Please wait a minute...
浙江大学学报(工学版)  2020, Vol. 54 Issue (4): 748-758    DOI: 10.3785/j.issn.1008-973X.2020.04.014
土木工程、交通工程     
混凝土中黏结型锚栓剪切试验方法
全学友1,2(),衡倩1,2,李雄宋1,刘连杰1,2
1. 重庆大学 土木工程学院,重庆 400045
2. 重庆大学 山地城镇建设与新技术教育部重点实验室,重庆 400045
Shear test methods of bonded anchor bolts in concrete
Xue-you QUAN1,2(),Qian HENG1,2,Xiong-song LI1,Lian-jie LIU1,2
1. College of Civil Engineering, Chongqing University, Chongqing 400045, China
2. Key Laboratory of New Technology for Construction of Cities in Mountain Area, Chongqing University, Chongqing 400045, China
 全文: PDF(1922 KB)   HTML
摘要:

针对单独锚栓剪切试验方法(SSTM)存在的缺陷,提出2套在加载板尾部配置辅助锚栓的双锚栓剪切试验方法(DSTM). 总计6个直径规格、90个锚栓的比对剪切试验表明,单独锚栓剪切试验获得的承载力低于双锚栓剪切试验获得的承载力,但均能达到以0.6倍锚栓杆体抗拉强度表示的理论剪切承载力的水平;单独锚栓试验加载板的转动导致剪力-位移实测曲线存在明显的离散性;在双锚栓试验中,对辅助锚栓施加约2.0 kN的预紧力,就能在加载板转动约束体系中建立有效的连接,借助辅助锚栓的拉伸刚度有效限制加载板的转动,显著降低剪力-位移试验曲线的离散性. 2套双锚栓剪切试验方法获得的试验结果具有一致性,作为辅助锚栓使用时承担拉力的历史不会影响其剪切性能.

关键词: 单锚栓剪切试验(SSTM)双锚栓剪切试验(DSTM)辅助锚栓离散性剪力-位移曲线    
Abstract:

Two sets of dual anchors shear test methods (DSTMs) were proposed by considering the shortcomings of single anchor shear test method (SSTM). An auxiliary anchor was provided at the rear end of loading plate. Test results of 90 anchor bolts in six diameters show that the shear capacity obtained from SSTM is lower than that from DSTM, but all of them being larger than the theoretical values expressed in 0.6 times the shaft tensile fracture strength. As a result of tilting of loading plate toward the pull force, measured shear-displacement curves from SSTM had higher stochastic characteristics than those from DSTMs. Positive connection would be reached in the tilting-restraining system by exerting about 2.0 kN pre-tension force in auxiliary anchor, and effective control of loading plate tilting would be reached by virtue of the tensile rigidity of auxiliary anchor, greatly reducing in the scattering of shear-displacement curves from DSTM. Determined consistency exists between test results from both of the two sets of DSTMs system, indicating that the tension history of auxiliary anchor would not adversely affect its shear properties.

Key words: single anchor shear test method (SSTM)    dual anchors shear test method (DSTM)    auxiliary anchor    scattering    shear-displacement curve
收稿日期: 2019-05-22 出版日期: 2020-04-05
CLC:  TU 398  
作者简介: 全学友(1963—),男,教授,博导,从事结构检测与加固技术的研究. orcid.org/0000-0001-8116-5488. E-mail: quanxueyou@163.com
服务  
把本文推荐给朋友
加入引用管理器
E-mail Alert
作者相关文章  
全学友
衡倩
李雄宋
刘连杰

引用本文:

全学友,衡倩,李雄宋,刘连杰. 混凝土中黏结型锚栓剪切试验方法[J]. 浙江大学学报(工学版), 2020, 54(4): 748-758.

Xue-you QUAN,Qian HENG,Xiong-song LI,Lian-jie LIU. Shear test methods of bonded anchor bolts in concrete. Journal of ZheJiang University (Engineering Science), 2020, 54(4): 748-758.

链接本文:

http://www.zjujournals.com/eng/CN/10.3785/j.issn.1008-973X.2020.04.014        http://www.zjujournals.com/eng/CN/Y2020/V54/I4/748

图 1  单独锚栓剪切试验
图 2  双锚栓剪切试验方案
图 3  半螺纹剪切锚栓
序号 锚栓规格 屈服强度/MPa 抗拉强度/MPa
1 M12 638.4 880.5
2 M14 578.2 1 038.2
3 M16 536.8 839.3
4 M18 598.8 976.3
5 M20 502.8 773.6
6 M22 467.4 752.7
表 1  锚栓力学性能指标
图 4  锚栓剪切试验试件设计图
试件编号 锚栓试验组
注:1)括号内标注的是该双锚栓试验组对应的辅助锚栓组,且该辅助锚栓是作为试验组进行设计的.
Block-1 SIN-12 SIN-14 DUA-12
(DUA-14)1)
DUA-14 DUB-12 DUB-14
Block-2 SIN-16 SIN-18 DUA-16
(DUA-18)
DUA-18 DUB-16 DUB-18
Block-3 SIN-20 SIN-22 DUA-20
(DUA-22)
DUA-22 DUB-20 DUB-22
表 2  混凝土试件上的锚栓试验组分布
图 5  试件Block-1锚栓布置图
图 6  单独锚栓试验组加载板
图 7  双锚栓试验组加载板
图 8  双锚栓剪切试验加载装置简图
图 9  SIN-12锚栓剪切破坏现象
图 10  DUB-14-3的辅助锚栓DUB-14-4受加载板尾部横梁的冲击影响
图 11  DUA-14的专用辅助锚栓受加载板尾部横梁冲击的典型照片
锚栓组 锚栓编号
DUB-12 全部锚栓
DUA-14 全部锚栓
DUB-14 DUB-14-4
表 3  受锚栓剪断冲击作用损伤的辅助锚栓
图 12  M12锚栓各试验组剪力-位移实测曲线
图 13  M14锚栓各试验组剪力-位移实测曲线
图 14  M16锚栓各试验组剪力-位移实测曲线
图 15  M18锚栓各试验组剪力-位移实测曲线
图 16  M20锚栓各试验组剪力-位移实测曲线
图 17  M22锚栓各试验组剪力-位移实测曲线
Vmax
M12 M14 M16 M18
5.31 7.81 8.47 11.29
表 4  辅助锚栓实测拉力最大值
图 18  辅助锚栓拉力
锚栓规格 Vu,s / kN V1 / kN V2,A / kN V2,B / kN V1/V2
M12 59.75 62.77 67.85 68.12 0.92
M14 95.89 98.41 106.12 106.41 0.92
M16 101.25 117.69 123.94 123.14 0.95
M18 149.06 156.14 169.49 164.92 0.93
M20 145.82 142.07 165.33 161.39 0.87
M22 171.67 155.80 202.80 201.31 0.77
表 5  各试验组实测平均剪切承载力
锚栓规格 SIN DUA DUB
r σ r σ r σ
M12 0.913 3.753 0.942 2.817 0.910 3.913
M14 0.840 6.149 0.975 2.459 0.964 2.877
M16 0.894 6.156 0.977 2.736 0.959 3.798
M18 0.857 10.065 0.962 4.692 0.978 3.900
M20 0.909 7.903 0.979 3.975 0.980 4.147
M22 0.924 9.227 0.961 6.470 0.936 8.548
表 6  锚栓试验组剪切屈服前剪力-位移实测数据的统计特征
图 19  加载板锚栓安装孔边缘的塑形变形
图 20  单独锚栓剪力-位移曲线随机性发生机理
锚栓
规格
KSIN/
(kN·mm-1
KDUA/
(kN·mm-1
KDUB/
(kN·mm-1
KDUB/
KDUA
KDUB/
KSIN
M12 9.788 12.682 21.098 1.66 2.16
M14 12.899 22.669 46.480 2.05 3.60
M16 16.764 38.785 38.387 0.99 2.28
M18 14.786 37.486 40.155 1.07 2.72
M20 13.288 44.774 41.911 0.94 3.15
M22 17.923 74.078 72.990 0.99 4.07
表 7  锚栓试验组剪切屈服刚度
图 21  试验组剪切屈服刚度比较
1 ROBERTS T M, HAJI-KAZEMI H Strengthening of under-reinforced concrete beams with mechanically attached steel plates[J]. International Journal of Cement Composites and Lightweight Concrete, 1989, 11 (1): 21- 27
doi: 10.1016/0262-5075(89)90032-8
2 AHMEDT M, OEHLERS D J, BRADFORD M A Retrofitting reinforced concrete beams by bolting steel plates to their sides. Part 1. behaviour and experiments[J]. Structural Engineering and Mechanics, 2000, 10 (3): 211- 226
doi: 10.12989/sem.2000.10.3.211
3 OEHLERS D J, AHMED M, NGUYENT N T, et al Retrofitting reinforced concrete beams by bolting steel plates to their sides. Part 2. transverse interaction and rigid plastic design[J]. Sturctural Engineering and Mechanics, 2000, 10 (3): 227- 243
doi: 10.12989/sem.2000.10.3.227
4 李英民, 韩大刚, 林文修 锚栓钢板加固法抗弯性能试验及设计方法[J]. 工程抗震与加固改造, 2006, 28 (5): 68- 71
LI Ying-ming, HAN Da-gang, LIN Wen-xiu Experiment study of flexural strengthening reinforced concrete beams by bolting steel plates and design method[J]. Earthquake Resistant Engineering and Retrofitting, 2006, 28 (5): 68- 71
doi: 10.3969/j.issn.1002-8412.2006.05.015
5 SU R K L, SIU W H, SMITH S T Effects of bolt-plate arrangements on steel plate strengthened reinforced concrete beams[J]. Engineering Structures, 2010, 32 (6): 1769- 1778
doi: 10.1016/j.engstruct.2010.02.028
6 LI L Z, LO S H, SU R K L Experimental study of moderately reinforced concrete beams strengthened with bolted-side steel plates[J]. Advances in Structural Engineering, 2013, 16 (3): 499- 516
doi: 10.1260/1369-4332.16.3.499
7 BARNES R A, BAGLIN P S, MAYS G C, et al External steel plate systems for the shear strengthening of reinforced concrete beams[J]. Engineering Structures, 2001, 23 (9): 1162- 1176
doi: 10.1016/S0141-0296(00)00124-3
8 LI L Z, CAI Z W, LU Z D, et al Shear performance of bolted side-plated reinforced concrete beams[J]. Engineering Structures, 2017, 144: 73- 87
doi: 10.1016/j.engstruct.2017.04.043
9 OEHLERS D J Development of design rules for retrofitting by adhesive bonding or bolting either FRP or steel plates to RC beams or slabs in bridges and buildings[J]. Composites Part A:Applied Science and Manufacturing, 2001, 32 (9): 1345- 1355
doi: 10.1016/S1359-835X(01)00089-6
10 全学友, 邓扬, 刘辉, 等 直接剪切型锚栓钢板加固混凝土梁的抗弯承载力试验研究[J]. 建筑结构, 2018, 48 (18): 88- 92
QUAN Xue-you, DENG Yang, LIU Hui, et al Experimental study on flexural capacity of concrete beams strengthened by direct-shear-bolted steel plate[J]. Building Structure, 2018, 48 (18): 88- 92
11 CHENG B, SU R K L Numerical studies of deep concrete coupling beams retrofitted with a laterally restrained steel plate[J]. Advances in Structural Engineering, 2011, 14 (5): 903- 915
doi: 10.1260/1369-4332.14.5.903
12 CHENG B, SU R K L, SHI C, et al Laterally restrained steel plate with stiffeners for seismic retrofitting of concrete coupling beams[J]. Advanced Steel Construction, 2016, 12 (2): 194- 210
13 SU R K L, ZHU Y Experimental and numerical studies of external steel plate strengthened reinforced concrete coupling beams[J]. Engineering Structures, 2005, 27 (10): 1537- 1550
doi: 10.1016/j.engstruct.2005.04.012
14 ZHU Y, SU R K L Behavior of strengthened reinforced concrete coupling beams by bolted steel plates, Part 2: evaluation of theoretical strength[J]. Structural Engineering and Mechanics, 2010, 34 (5): 563- 580
doi: 10.12989/sem.2010.34.5.563
15 ZHU Y, SU R K L, ZHOU F L Seismic behavior of strengthened reinforced concrete coupling beams by bolted steel plates, Part 1: experimental study[J]. Structural Engineering and Mechanics, 2007, 27 (2): 149- 172
doi: 10.12989/sem.2007.27.2.149
16 AL-SALLOUM Y A, ALRUBAIDI M A, ELSANADEDY H M, et al Strengthening of precast RC beam-column connections for progressive collapse mitigation using bolted steel plates[J]. Engineering Structures, 2018, 161: 146- 160
doi: 10.1016/j.engstruct.2018.02.009
17 Guideline for European technical approval of metal anchors for use in concrete: ETAG 001 [Z], 1997.
18 Standard test methods for strength of anchors in concrete elements: ASTM E488/E488M-15 [S]. [S.l.]: ASTM, 2015.
19 ELIGEHAUSEN R, MALLEE R, SILVA F. Anchorage in concrete construction [M]. [S.1.]: Ernst&Sohn, 2006.
[1] 傅新, 钱晓倩, 钱匡亮, 董凯, 阮方. 夏热冬冷地区采暖空调计算期确定方法[J]. 浙江大学学报(工学版), 2017, 51(4): 729-738.