无线电电子学、电信技术 |
|
|
|
|
微笔-激光直写组合加工制备多电极阵列系统 |
曹宇1, 刘建国2, 曾晓雁2 |
1. 温州大学 机电工程学院,浙江 温州 325000;2. 华中科技大学 光电子科学与工程学院,湖北 武汉 430074 |
|
Fabrication of multi-electrode array system by
micropen-laser hybrid direct writing technology |
CAO Yu1, LIU Jian-guo2, ZENG Xiao-yan2 |
1. College of Mechanical and Electrical Engineering, Wenzhou University , Wenzhou 325000, China; 2. College of
Optoelectronics Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074,China |
[1] 吴丹,封洲燕,王静.微电极阵列神经元锋电位信号的去噪方法[J].浙江大学学报:工学版, 2010, 44(1): 104-110.
WU Dan, FENG Zhouyan, WANG Jing, Novel denoising approach to neuronal spike signals recorded by micro electrode array[J]. Journal of Zhejiang University: Engineering Science, 2010, 44(1): 104-110.
[2] 吴成雄,蔡华,胡宁,等.基于集成芯片的细胞生理多参数自动分析仪[J]. 浙江大学学报:工学版, 2011, 45(10): 1-7.
WU Chengxiong, CAI Hua, HU Ning, et al. Design of automatic analysis instrument for cell physiological multiparameter detection based on integrated chip[J]. Journal of Zhejiang University: Engineering Science, 2011, 45(10): 1-7.
[3] 陈传平.基于多电极阵列的培养神经元网络动态特征分析[D].武汉: 华中科技大学,2006: 14-19.
CHEN Chuanpin. Analyzing the dynamics of cultured neuronal network based on multielectrode arrays [D]. Wuhan: Huazhong University of Science and Technology, 2006: 14-19.
[4] 吴浩扬,吴裕远.神经芯片技术的研究进展[J].生物化学与生物物理进展,2004, 31(1): 89-93.
WU Haoyang, WU Yuyuan. Progress in neuro chip technology[J]. Progress in Biochemistry and Biophysics, 2004, 31(1): 89-93.
[5] 曹宇.激光微笔/微喷直写集成制造MEMS微结构关键技术研究[D].武汉:华中科技大学, 2009: 1-20.
CAO Yu. Study on lasermicropen/microjet direct writing technology for integrated fabrication of mems microstructures [D]. Wuhan: Huazhong University of Science and Technology, 2009: 1-20.
[6] CAI Zhixiang, ZENG Xiaoyan, LIU Jianguo. Laser direct writing of conductive silver film on polyimide surface from decomposition of organometallic ink[J]. Journal of Electronic Materials, 2010, 40(03): 301-305.
[7] DUPORT S, MILLERIN C, MULLER D, et al. A metallic multisite recording system designed for continuous longterm monitoring of electrophysiological activity in slice cultures[J]. Biosensors and Bioelectronics, 1999,14: 365-376.
[8] GHOLMIEH G, SORSSOU W, COURELLIS S, et al. A biosensor for detecting changes in cognitive processing based on nonlinear systems analysis[J]. Biosensors and Bioelectronics, 2001,16: 491-501.
[9] CAO Yu, ZHOU Liangwen, WANG Xiaoye, et al. MicroPen directwrite deposition of polyimide[J]. Microelectronics Engineering, 2009, 86 (10): 1989-1993. |
|