Please wait a minute...
浙江大学学报(工学版)
土木工程、交通工程     
多孔建筑材料水蒸气扩散系数的瞬态测试方法
易思阳1,金虹庆1,范利武1,徐旭2,俞自涛1,葛坚3
1. 浙江大学 热工与动力系统研究所,浙江 杭州 310027;2. 中国计量学院 计量测试工程学院,浙江 杭州 310018;3. 浙江大学 建筑技术研究所,浙江 杭州 310058
Transient determination of water vapor diffusion coefficient of porous building materials
YI Si yang1,JIN Hong qing1,FAN Li wu1,XU Xu2,YU Zi tao1,GE Jian3
1. Institute of Thermal Science and Power Systems,Zhejiang University,Hangzhou 310027,China;2. College of Metrological and Measurement Engineering,China Jiliang University,Hangzhou 310018,China;3. Institute of Architectural Technology,Zhejiang University,Hangzhou 310058,China
 全文: PDF(772 KB)   HTML
摘要:

为了缩短多孔建筑材料水蒸气扩散系数的测试时间,提出基于求解瞬态一维质扩散反问题的瞬态测试方法.以典型的多孔建筑材料B04型加气混凝土为例,采用电容式相对湿度传感器对试样内部的相对湿度分布进行动态监测,以实现该瞬态测试方法,由瞬态一维质扩散反问题的解得到加气混凝土试样的水蒸气扩散系数.结果表明,瞬态测量值与通过稳态法测试得到的相同相对湿度下的值吻合度较高,最大偏差在30%以内.与耗时长达2个月以上的稳态法相比,该瞬态测试方法耗时仅需数天,可以仅由一次测试获得水蒸气扩散系数随相对湿度的变化规律曲线,极大地提高了测试效率. 

Abstract:

A transient method was proposed based on solving an inverse problem of transient one dimensional mass diffusion in order to shorten the measurement time for determination of the water vapor diffusion coefficient of porous building materials. A typical porous building material was taken as an example by choosing the type B04 autoclaved aerated concrete. The proposed transient method was implemented by dynamically monitoring the relative humidity distribution inside the sample with a set of capacitor based hygrometers. The water vapor diffusion coefficient was finally acquired via the solution of the inverse problem of transient one dimensional mass diffusion. Results showed that the transient results accorded with those measured by the steady state method with a maximum relative deviation being less than 30%. The proposed transient method only took several days to accomplish compared to the steady state method that lasted for more than 2 months. The significantly improved measurement efficiency was due to the fact that the variation of water vapor diffusion coefficient as a function of relative humidity can be determined by a single experiment.

出版日期: 2016-03-31
:  TU 111  
基金资助:

 国家自然科学基金资助项目(51378482).

通讯作者: 范利武,男,副教授. ORCID: 0000 0001 8845 5058.     E-mail: liwufan@zju.edu.cn
作者简介: 易思阳(1991-),女,硕士生,从事建筑节能与室内热湿环境调控研究. ORCID: 0000 0002 2924 6384. E-mail: yizhiyang0211@zju.edu.cn
服务  
把本文推荐给朋友
加入引用管理器
E-mail Alert
RSS
作者相关文章  

引用本文:

易思阳,金虹庆,范利武,徐旭,俞自涛,葛坚. 多孔建筑材料水蒸气扩散系数的瞬态测试方法[J]. 浙江大学学报(工学版), 10.3785/j.issn.1008-973X.2016.01.003.

YI Si yang,JIN Hong qing,FAN Li wu,XU Xu,YU Zi tao,GE Jian. Transient determination of water vapor diffusion coefficient of porous building materials. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 10.3785/j.issn.1008-973X.2016.01.003.

链接本文:

http://www.zjujournals.com/eng/CN/10.3785/j.issn.1008-973X.2016.01.003        http://www.zjujournals.com/eng/CN/Y2016/V50/I1/16

[1] 张华玲,刘朝,付祥钊. 多孔墙体湿分传递与室内热湿环境研究[J]. 暖通空调,2006,36(10):29-34.
ZHANG Hua ling, LIU Chao, FU Xiang zhao. Study on moisture transfer in porous building components and indoor environment [J]. Journal of Heating, Ventilating and Air Conditioning, 2006, 36(10): 29-34.
[2] ROELS S, TALUKDAR P, JAMES C, et al. Reliability of material data measurements for hygroscopic buffering [J]. International Journal of Heat and Mass Transfer, 2010, 53(23): 5355-5363.
[3] 周晓燕,彭秋云. 定向结构板内水蒸汽稳态扩散系数的研究[J]. 林产工业,2001,28(6):13-14.
ZHOU Xiao yan, PENG Qiu yun. Study on steady state diffusion coefficient of vapour in OSB [J]. China Forest Products Industry, 2001, 28(6): 13-14.
[4] ISO 12572: 2001. Hygrothermal performance of building materials and products: determinations of water vapor transmission properties [S]. Switzerland:ISO, 2001.
[5] ISO 12571: 2000. Hygrothermal performance of building materials and products:determination of hygroscopic sorption properties [S]. Switzerland:ISO, 2000.
[6] COLLET F, ACHCHAQ F, DJELLAB K, et al. Water vapor properties of two hemp wools manufactured with different treatments [J]. Construction and Building Materials, 2011, 25(2): 1079-1085.
[7] ARFVIDSSON J, CUNNINGHAM M J. A transient technique for determining diffusion coefficients in hygroscopic materials [J]. Building and Environment, 2000, 35(3): 239-249.
[8] DELGADO J, RAMOS N M M, DE FREITAS V P. Application of hybrid and moment methods to the measurement of moisture diffusion coefficients of building materials [J]. Heat and Mass Transfer, 2011, 47(11): 1491-1498.
[9] PAVLK Z, UMR J, PAVLKOV M, et al. A Boltzmann transformation method for investigation of water vapor transport in building materials [J]. Journal of Building Physics, 2012, 35(3): 213-223.
[10] CARMELIET J, HENS H, ROELS S, et al. Determination of the liquid water diffusivity from transient moisture transfer experiments [J]. Journal of Thermal Envelope and Building Science, 2004, 27(4): 277-305.
[11] KUISHAN L, XU Z, JUN G. Experimental investigation of hygrothermal parameters of building materials under isothermal conditions [J]. Journal of Building Physics, 2009, 32(4): 355-370.
[12] COLLET F, CHAMOIN J, PRETOT S, et al. Comparison of the hygric behaviour of three hemp concretes [J]. Energy and Buildings, 2013, 62: 294-303.
[13] 姚晓莉,易思阳,范利武,等. 不同孔隙率下含湿加气混凝土的有效导热系数[J]. 浙江大学学报:工学版, 2015, 49(6):1101-1107.
YAO Xiao li, YI Si yang, FAN Li wu, et al. Effective thermal conductivity of moist aerated concrete with various porosities [J]. Journal of Zhejiang University: Engineering Science, 2015, 49(6): 1101-1107.
[14] LACKEY J C, MARCHAND R G, KUMARAN M K. A logical extension of the ASTM standard E96 to determine the dependence of water vapour transmission on relative humidity [J]. ASTM Special Technical Publication, 1997, 1320: 456-470.
[15] JERMAN M, KEPPERT M, VY′BORNY′ J, et al. Hygric, thermal and durability properties of autoclaved aerated concrete [J]. Construction and Building Materials, 2013, 41: 352-359.
[16] 冯驰,吴晨晨,冯雅,等. 干燥方法和试件尺寸对加气混凝土等温吸湿曲线的影响[J]. 建筑材料学报,2014,17(1):132-137.
FENG Chi, WU Chen chen, FENG Ya, et al. Effect of drying methods and sample sizes on moisture absorption isotherms of aerated concrete [J]. Journal of Building Materials, 2014, 17(1): 132-137.
[17] GALBRAITH G H, MCLEAN R C, TAO Z. Vapour permeability: suitability and consistency of current test procedures [J]. Building Services Engineering Research and Technology, 1993, 14(2): 67-70.

[1] 白如帆, 雷建坤, 张亮. 面向大数据试验场应用的资源优化分配[J]. 浙江大学学报(工学版), 2017, 51(6): 1225-1232.
[2] 阮方, 钱晓倩, 钱匡亮, 余亚超, 施水华. 夏热冬冷地区居住建筑外墙外保温的反节能现象[J]. 浙江大学学报(工学版), 2016, 50(12): 2343-2349.
[3] 董凯, 赖俊英, 钱晓倩, 詹树林, 阮方. 夏热冬冷地区居住建筑水平式外遮阳节能效果[J]. 浙江大学学报(工学版), 2016, 50(8): 1431-1437.
[4] 阮方,钱晓倩,朱耀台,吴敏莉. 分室间歇用能对墙体内外保温节能效果的影响[J]. 浙江大学学报(工学版), 2016, 50(1): 1-7.
[5] 欧阳金龙, 王春苑, 毛伟, 邓小燕. 利用EnIR和EvIR优化既有住宅节能改造方案[J]. 浙江大学学报(工学版), 2014, 48(8): 1391-1398.
[6] 王子阳, 邵卫云, 张仪萍. 考虑土壤分层的地源热泵圆柱面热源模型[J]. J4, 2013, 47(8): 1338-1345.
[7] 张长兴, 胡松涛, 刘玉峰, 丛晓春. 基于系统优化的岩土热物性确定方法[J]. J4, 2012, 46(12): 2237-2242.
[8] 王子阳, 张仪萍, 战国会, 俞亚南. 有渗流时埋管换热器传热模型[J]. J4, 2012, 46(8): 1450-1456.
[9] 战国会, 张仪萍, 徐坚, 俞亚南. 地源热泵群孔长期换热有限长体热源模型[J]. J4, 2011, 45(8): 1411-1415.
[10] 战国会, 俞亚南. 地源热泵有限长圆柱面和圆柱体热源模型[J]. J4, 2011, 45(6): 1104-1107.
[11] 俞亚南, 徐坚, 冯建江. 粉性土导热系数的室内实验研究[J]. J4, 2010, 44(1): 180-183.
[12] 欧阳金龙, 王春苑, 毛伟, 邓小燕. 利用EnIR和EvIR优化既有住宅节能改造方案[J]. 浙江大学学报(工学版), 2014, 1(8): 1391-1398.