土木工程、交通工程 |
|
|
|
|
多孔建筑材料水蒸气扩散系数的瞬态测试方法 |
易思阳1,金虹庆1,范利武1,徐旭2,俞自涛1,葛坚3 |
1. 浙江大学 热工与动力系统研究所,浙江 杭州 310027;2. 中国计量学院 计量测试工程学院,浙江 杭州 310018;3. 浙江大学 建筑技术研究所,浙江 杭州 310058 |
|
Transient determination of water vapor diffusion coefficient of porous building materials |
YI Si yang1,JIN Hong qing1,FAN Li wu1,XU Xu2,YU Zi tao1,GE Jian3 |
1. Institute of Thermal Science and Power Systems,Zhejiang University,Hangzhou 310027,China;2. College of Metrological and Measurement Engineering,China Jiliang University,Hangzhou 310018,China;3. Institute of Architectural Technology,Zhejiang University,Hangzhou 310058,China |
引用本文:
易思阳,金虹庆,范利武,徐旭,俞自涛,葛坚. 多孔建筑材料水蒸气扩散系数的瞬态测试方法[J]. 浙江大学学报(工学版), 10.3785/j.issn.1008-973X.2016.01.003.
YI Si yang,JIN Hong qing,FAN Li wu,XU Xu,YU Zi tao,GE Jian. Transient determination of water vapor diffusion coefficient of porous building materials. JOURNAL OF ZHEJIANG UNIVERSITY (ENGINEERING SCIENCE), 10.3785/j.issn.1008-973X.2016.01.003.
链接本文:
http://www.zjujournals.com/eng/CN/10.3785/j.issn.1008-973X.2016.01.003
或
http://www.zjujournals.com/eng/CN/Y2016/V50/I1/16
|
[1] 张华玲,刘朝,付祥钊. 多孔墙体湿分传递与室内热湿环境研究[J]. 暖通空调,2006,36(10):29-34.
ZHANG Hua ling, LIU Chao, FU Xiang zhao. Study on moisture transfer in porous building components and indoor environment [J]. Journal of Heating, Ventilating and Air Conditioning, 2006, 36(10): 29-34.
[2] ROELS S, TALUKDAR P, JAMES C, et al. Reliability of material data measurements for hygroscopic buffering [J]. International Journal of Heat and Mass Transfer, 2010, 53(23): 5355-5363.
[3] 周晓燕,彭秋云. 定向结构板内水蒸汽稳态扩散系数的研究[J]. 林产工业,2001,28(6):13-14.
ZHOU Xiao yan, PENG Qiu yun. Study on steady state diffusion coefficient of vapour in OSB [J]. China Forest Products Industry, 2001, 28(6): 13-14.
[4] ISO 12572: 2001. Hygrothermal performance of building materials and products: determinations of water vapor transmission properties [S]. Switzerland:ISO, 2001.
[5] ISO 12571: 2000. Hygrothermal performance of building materials and products:determination of hygroscopic sorption properties [S]. Switzerland:ISO, 2000.
[6] COLLET F, ACHCHAQ F, DJELLAB K, et al. Water vapor properties of two hemp wools manufactured with different treatments [J]. Construction and Building Materials, 2011, 25(2): 1079-1085.
[7] ARFVIDSSON J, CUNNINGHAM M J. A transient technique for determining diffusion coefficients in hygroscopic materials [J]. Building and Environment, 2000, 35(3): 239-249.
[8] DELGADO J, RAMOS N M M, DE FREITAS V P. Application of hybrid and moment methods to the measurement of moisture diffusion coefficients of building materials [J]. Heat and Mass Transfer, 2011, 47(11): 1491-1498.
[9] PAVLK Z, UMR J, PAVLKOV M, et al. A Boltzmann transformation method for investigation of water vapor transport in building materials [J]. Journal of Building Physics, 2012, 35(3): 213-223.
[10] CARMELIET J, HENS H, ROELS S, et al. Determination of the liquid water diffusivity from transient moisture transfer experiments [J]. Journal of Thermal Envelope and Building Science, 2004, 27(4): 277-305.
[11] KUISHAN L, XU Z, JUN G. Experimental investigation of hygrothermal parameters of building materials under isothermal conditions [J]. Journal of Building Physics, 2009, 32(4): 355-370.
[12] COLLET F, CHAMOIN J, PRETOT S, et al. Comparison of the hygric behaviour of three hemp concretes [J]. Energy and Buildings, 2013, 62: 294-303.
[13] 姚晓莉,易思阳,范利武,等. 不同孔隙率下含湿加气混凝土的有效导热系数[J]. 浙江大学学报:工学版, 2015, 49(6):1101-1107.
YAO Xiao li, YI Si yang, FAN Li wu, et al. Effective thermal conductivity of moist aerated concrete with various porosities [J]. Journal of Zhejiang University: Engineering Science, 2015, 49(6): 1101-1107.
[14] LACKEY J C, MARCHAND R G, KUMARAN M K. A logical extension of the ASTM standard E96 to determine the dependence of water vapour transmission on relative humidity [J]. ASTM Special Technical Publication, 1997, 1320: 456-470.
[15] JERMAN M, KEPPERT M, VY′BORNY′ J, et al. Hygric, thermal and durability properties of autoclaved aerated concrete [J]. Construction and Building Materials, 2013, 41: 352-359.
[16] 冯驰,吴晨晨,冯雅,等. 干燥方法和试件尺寸对加气混凝土等温吸湿曲线的影响[J]. 建筑材料学报,2014,17(1):132-137.
FENG Chi, WU Chen chen, FENG Ya, et al. Effect of drying methods and sample sizes on moisture absorption isotherms of aerated concrete [J]. Journal of Building Materials, 2014, 17(1): 132-137.
[17] GALBRAITH G H, MCLEAN R C, TAO Z. Vapour permeability: suitability and consistency of current test procedures [J]. Building Services Engineering Research and Technology, 1993, 14(2): 67-70. |
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
|
Shared |
|
|
|
|
|
Discussed |
|
|
|
|