[1] MADOU M J, LU Y, LAI S, et al. A novel design on a CD disc for 2-point calibration measurement [J]. Sensors and Actuators A: Physical, 2001, 91(3): 301-306.
[2] AUROUX P A, IOSSIFIDIS D, REYES D R, et al. Micro total analysis systems. 2. Analytical standard operations and applications [J]. Analytical Chemistry, 2002, 74(12): 2631-2652.
[3] 范建华,邓永波,宣明,等.CDlike全血分析芯片内压缩空气的定量泵送[J].光学精密工程,2014,22(10):2733-2739.
[3] FAN Jianhua, DENG Yongbo, XUAN Ming,et al. Penumaticpumping metering in CDlike microfluidic chip for whole blood analysis [J].Optics and Precision Engineering ,2014,22(10):2733-2739.
[4] MADOU M J, ZOVAL J, JIA G, et al. Lab on a CD [J]. Annual review of Biomedical Engineering, 2006, 8(1): 601-628.
[5]KIM J, KIDO H, RANGEL R H, et al. Passive flow switching valves on a centrifugal microfluidic platform [J]. Sensors and actuators B: Chemical, 2008, 128(2): 613621.
[6] HUANG Y C, SUNG W L, LAI W C, et al. Design and implementation of timedelay switch triggered by inertia load[C]∥Micro Electro Mechanical Systems (MEMS). 2013 IEEE 26th International Conference on. Tsipei China: IEEE, 2013: 729-732.
[7] SEN P, KIM C J. A fast liquidmetal droplet microswitch using ewoddriven contactline sliding [J]. Journal of Microelectromechanical Systems,2009, 1(18): 174-185.
[8] 杜新,张平,刘永顺,等.基于PDMS和玻璃材料的毛细管被动阀临界压力分析[J].光学精密工程,2011,19(8): 1852-1858.
DU Xin,ZHANG Ping,LIU Yongshun,et al.Burst pressure of capillary burst valve based on glass and PDMS [J].Optics and Precision Engineering, 2011,19(8): 1852-1858.
[9] MELIN J, ROXHED N, GIMENEZ G,et al. A liquidtriggered liquid microvalve for onchip flow control [J].Sensors and Actuators B,100(2004), 463-468.
[10] KAZEMZADEH A, GANESAN P, LBRAHIM F,et al.Guided routing on spinning microfluidic platforms [J].RSC Advances, 2015, 5, 8669,DOI: 10.1039/c4ra14397c.
[11] ZENG J, BANERJEE D, DESHPANDE M,et al. Design analyses of capillary burst valves in centrifugal microfluidics [C]∥In: Micro Total Analysis Systems 2000.In: Proceedings of the UTAS 2000 Symposium: Enschede: The Netherlands, 2000, 579-582.
[12] DUFFY D C, GILLIS H L, LIN J, et al. Microfabricated centrifugal microfluidic systems: characterization and multiple enzymatic assays[J]. Analytical Chemistry,1999, 71: 4669-4678.
[13] MAN P F, MASTRANGELO C H, BURNS M A,et al. Microfabricated capillarydriven stop valve and sample injector[C]∥In: Proceedings of 11th annual international workshop on microelectro mechanical systems. Heidelberg: \[s.n.\], 1998, pp 45-50.
[14] LEU T S, CHANG P Y. Pressure barrier of capillary stop valves in micro sample separators [J]. Sensors and Actuators A: Physical, 2004, 115(2): 508-515.
[15] CHEN J M, HUANG P C, LIN M G. Analysis and experiment of capillary valves for microfluidics on a rotating disk [J]. Microfluidics and Nanofluidics, 2008, 4(5): 427-437.
[16] CHO H, KIM H Y, KANG J Y, et al. Capillary passive valve in microfluidic systems[C]∥In: Technical Proceedings of the 2004 NSTI Nanotechnology Conference and trade show—NSTI Nanotech 2004. Boston: Massachusetts. Nano Science and Technology Institute (NSTI), 1. 263-266.
[17] THOP T H G, SOROORI S, IBRHIM F, et al. Theoretical development and critical analysis of burst frequency equations for passive valves on centrifugal microfluidic platforms [J]. Medical & Biological Engineering & Computing, 2013, 51(5): 525-535.
[18] CHO H, KIM H Y, KANG J Y, et al. How the capillary burst microvalve works [J]. Journal of Colloid and Interface science, 2007, 306(2): 379-385.5. |