Please wait a minute...
Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology)  2007, Vol. 8 Issue (6): 416-421    DOI: 10.1631/jzus.2007.B0416
Biomedicine     
Stabilization of an abutment under a rigidly fixed bridge by holographical-speckle interferometry
ZHANG Yan-zhen, ZHOU Yan-chun, LIU Li, LU Yang, HIROFUMI Yatani
Department of Stomatology, the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China; Department of Stomatology, Hospital of Zhejiang University, Hangzhou 310027, China; Affiliated Stomatology Hospital of Zhejiang University, Hangzhou 310006, China; Department of Mechanics, Zhejiang University, Hangzhou 310027, China; Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka 565-0871, Japan
Download:     PDF (0 KB)     
Export: BibTeX | EndNote (RIS)      

Abstract  Objective: There are no detailed reports of three-dimensional measurement of abutment teeth in mastication, because it is knotty to observe the rotation in chewing directly, and inexact to estimate indirectly. This work studies the three-dimensional stability of rigidly fixed bridge under the stresses of distributed loads and concentrated loads by optical method that gives the tip angle and rotation angle calculated directly based on measurement data. Methods: The specimen, taken from a 25-year-old male, was a left mandible without the second premolars and the first molars. As abutments, first premolar and second molar have complete periodontium. The specimen was soaked in formaldehyde solution. The bridge was fixed between two abutment teeth (first premolars and second molars), and the mandible was cemented in a steel box. The load was increased from 0 kg to 23 kg. Laser holographic technique was used to measure the three-dimensional bit shift of the dens, both buccolingual bit shift and mesiodistal bit shift, and determine tip angle and rotation angle. Results: The effects of stress distribution on the rigidly fixed bridge were evaluated, and stabilization of the bridge under the stresses of distributed loads and concentrated loads, respectively, were analyzed. The results showed that the tips of two abutments were very similar, and no distinct difference was observed between the distributed load and the concentrated load. However, the maximum rotation angle for the distributed load was two to four times as large as that for the concentrated load. In the experiment, the tip angle of the abutment teeth was no more than 0.65 degree, and the rotation angle was no more than 0.60 degree. All maximum angles occurred in the second molar. Conclusion: The fixed bridge is considered to be safe. In addition, a method for measuring the rotation angle was provided effectively.

Key wordsRigidly fixed bridge      Tip angle      Maximum rotation angle      Laser holographical-speckle interferometry     
Received: 30 May 2006     
CLC:  R783  
  TB8  
Cite this article:

ZHANG Yan-zhen, ZHOU Yan-chun, LIU Li, LU Yang, HIROFUMI Yatani. Stabilization of an abutment under a rigidly fixed bridge by holographical-speckle interferometry. Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology), 2007, 8(6): 416-421.

URL:

http://www.zjujournals.com/xueshu/zjus-b/10.1631/jzus.2007.B0416     OR     http://www.zjujournals.com/xueshu/zjus-b/Y2007/V8/I6/416

[1] Hui-ping Lin, Jun Lin, Juan Li, Jing-hong Xu, Christian Mehl. In vitro remineralization of hybrid layers using biomimetic analogs[J]. Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology), 2016, 17(11): 864-873.
[2] Mu-zi Li, Jin-rui Wang, Hong Liu, Xia Wang, Kang Gan, Xiu-ju Liu, De-li Niu, Xiao-qing Song. Effects of light curing modes and ethanol-wet bonding on dentin bonding properties[J]. Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology), 2016, 17(9): 703-711.
[3] Jun Lin, Wei-ying Zheng, Peng-ruo-feng Liu, Ning Zhang, Hui-ping Lin, Yi-jing Fan, Xin-hua Gu, Oliver Vollrath, Christian Mehl. Influence of casein phosphopeptide-amorphous calcium phosphate application, smear layer removal, and storage time on resin-dentin bonding[J]. Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology), 2014, 15(7): 649-660.
[4] Cai-yun Mao, Jia-jia Zhao, Wei Wang, Xin-hua Gu. Effects of EDTA irrigation and water storage on the bonding durability of different adhesive resin cements to intra-radicular dentin[J]. Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology), 2014, 15(4): 399-404.
[5] Min Han, Rong-yang Wang, Hong Liu, Xiu-juan Zhu, Fu-lan Wei, Tao Lv, Na-na Wang, Li-hua Hu, Guo-ju Li, Dong-xu Liu, Chun-ling Wang. Association between mandibular posterior alveolar morphology and growth pattern in a Chinese population with normal occlusion[J]. Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology), 2013, 14(1): 25-32.
[6] Ling Zhang, Tian Tang, Zhen-liang Zhang, Bing Liang, Xiao-miao Wang, Bai-ping Fu. Improvement of enamel bond strengths for conventional and resin-modified glass ionomers: acid-etching vs. conditioning[J]. Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology), 2013, 14(11): 1013-1024.
[7] Zhen-zhen Peng, Xin-min Chen, Jun Wang, Ai-jie Li, Zu-jie Xu. Effect of proximal contact strength on the three-dimensional displacements of implant-supported cantilever fixed partial dentures under axial loading[J]. Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology), 2013, 14(6): 526-532.
[8] Rong-yang Wang, Min Han, Hong Liu, Chun-ling Wang, Hong-hong Xian, Lei Zhang, Shi-jie Zhang, Dong-xu Liu. Establishment of reference mandibular plane for anterior alveolar morphology evaluation using cone beam computed tomography[J]. Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology), 2012, 13(11): 942-947.
[9] Qing-yuan Guo, Shi-jie Zhang, Hong Liu, Chun-ling Wang, Fu-lan Wei, Tao Lv, Na-na Wang, Dong-xu Liu. Three-dimensional evaluation of upper anterior alveolar bone dehiscence after incisor retraction and intrusion in adult patients with bimaxillary protrusion malocclusion[J]. Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology), 2011, 12(12): 990-997.
[10] Razvan Ghinea, Laura Ugarte-Alvan, Ana Yebra, Oscar E. Pecho, Rade D. Paravina, Maria del Mar Perez. Influence of surface roughness on the color of dental-resin composites[J]. Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology), 2011, 12(7): 552-562.