Please wait a minute...
Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology)  2014, Vol. 15 Issue (7): 649-660    DOI: 10.1631/jzus.B1300216
Articles     
Influence of casein phosphopeptide-amorphous calcium phosphate application, smear layer removal, and storage time on resin-dentin bonding
Jun Lin, Wei-ying Zheng, Peng-ruo-feng Liu, Ning Zhang, Hui-ping Lin, Yi-jing Fan, Xin-hua Gu, Oliver Vollrath, Christian Mehl
Department of Stomatology, the First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310003, China; Institute of Medical Informatics and Statistics, University Hospital Schleswig-Holstein, Campus Kiel, 24105 Kiel, Germany; Department of Prosthodontics, Propaedeutics and Dental Materials, Christian-Albrechts University at Kiel, Arnold-Heller-Stra?e 16, 24105 Kiel, Germany
Download:     PDF (0 KB)     
Export: BibTeX | EndNote (RIS)      

Abstract  The aim of this study is to evaluate the influence of Tooth Mousse (TM) application, smear layer removal, and storage time on resin-dentin microtensile bond strength (µTBS). Dentin specimens were divided into two groups: (1) smear layer covered; (2) smear layer removed using 15% EDTA for 90 s. In each group, half the specimens were treated once with TM for 60 min. After bonding procedures using a two-step self-etching adhesive (Clearfil SE Bond (CSE); Kuraray Medical, Tokyo, Japan), an all-in-one adhesive (G-Bond (GB); GC Corp, Tokyo, Japan), and a total-etch adhesive (Adper Single Bond 2 (SB); 3M ESPE, St. Paul, MN, USA), the specimens were stored for 3 d or 6 months in deionized water at 37 °C, and µTBS was tested and analyzed. With the exception of SB (no TM application) and GB, the μTBS was significantly increased for CSE and SB using EDTA pre-conditioning and 3 d of storage (P≤0.001). Bond strength of GB decreased significantly when using EDTA (3 d storage, P<0.05). TM application only increased the μTBS of GB (no EDTA) and SB (with EDTA) after 3 d (P≤0.02). Comparing the adhesives after 3 d of storage, CSE exhibited the greatest μTBS values followed by GB and SB (P≤0.02). The factors of adhesive, EDTA, and TM did not show any significant impact on μTBS when specimens were stored for 6 months (P>0.05). The additional application of TM and EDTA for cavity preparation seems only to have a short-term effect, and no influence on µTBS of dentin bonds after a period of 6 months.

Key wordsTooth Mousse      Ethylenediaminetetraacetic acid (EDTA)      Casein phosphopeptide-amorphous calcium phosphate      Smear layer      Bond strength     
Received: 14 August 2013      Published: 06 July 2014
CLC:  R783.1  
Cite this article:

Jun Lin, Wei-ying Zheng, Peng-ruo-feng Liu, Ning Zhang, Hui-ping Lin, Yi-jing Fan, Xin-hua Gu, Oliver Vollrath, Christian Mehl. Influence of casein phosphopeptide-amorphous calcium phosphate application, smear layer removal, and storage time on resin-dentin bonding. Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology), 2014, 15(7): 649-660.

URL:

http://www.zjujournals.com/xueshu/zjus-b/10.1631/jzus.B1300216     OR     http://www.zjujournals.com/xueshu/zjus-b/Y2014/V15/I7/649

[1] Ling Zhang, Tian Tang, Zhen-liang Zhang, Bing Liang, Xiao-miao Wang, Bai-ping Fu. Improvement of enamel bond strengths for conventional and resin-modified glass ionomers: acid-etching vs. conditioning[J]. Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology), 2013, 14(11): 1013-1024.