U-shaped energy loss curves utilization for distributed generation optimization in distribution networks
Reza Ebrahimi, Mehdi Ehsan, Hassan Nouri
Department of Electrical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran; Centre of Excellence in Power System Management and Control (CEPSMC), Sharif University of Technology, Tehran, Iran; Department of Engineering Design and Mathematics, University of the West of England (UWE Bristol), Bristol, UK
Download:   PDF(0KB)
Export: BibTeX | EndNote (RIS)      

Abstract  We propose novel techniques to find the optimal location, size, and power factor of distributed generation (DG) to achieve the maximum loss reduction for distribution networks. Determining the optimal DG location and size is achieved simultaneously using the energy loss curves technique for a pre-selected power factor that gives the best DG operation. Based on the network’s total load demand, four DG sizes are selected. They are used to form energy loss curves for each bus and then for determining the optimal DG options. The study shows that by defining the energy loss minimization as the objective function, the time-varying load demand significantly affects the sizing of DG resources in distribution networks, whereas consideration of power loss as the objective function leads to inconsistent interpretation of loss reduction and other calculations. The devised technique was tested on two test distribution systems of varying size and complexity and validated by comparison with the exhaustive iterative method (EIM) and recently published results. Results showed that the proposed technique can provide an optimal solution with less computation.

Key wordsDistributed generation (DG)      Distribution networks      Loss reduction      DG optimization      Energy loss curves     
Received: 14 October 2012      Published: 06 November 2013
CLC:  TM714.3  
Cite this article:

Reza Ebrahimi, Mehdi Ehsan, Hassan Nouri. U-shaped energy loss curves utilization for distributed generation optimization in distribution networks. Front. Inform. Technol. Electron. Eng., 2013, 14(11): 887-898.

URL:

http://www.zjujournals.com/xueshu/fitee/10.1631/jzus.C1200282     OR     http://www.zjujournals.com/xueshu/fitee/Y2013/V14/I11/887


U-shaped energy loss curves utilization for distributed generation optimization in distribution networks

We propose novel techniques to find the optimal location, size, and power factor of distributed generation (DG) to achieve the maximum loss reduction for distribution networks. Determining the optimal DG location and size is achieved simultaneously using the energy loss curves technique for a pre-selected power factor that gives the best DG operation. Based on the network’s total load demand, four DG sizes are selected. They are used to form energy loss curves for each bus and then for determining the optimal DG options. The study shows that by defining the energy loss minimization as the objective function, the time-varying load demand significantly affects the sizing of DG resources in distribution networks, whereas consideration of power loss as the objective function leads to inconsistent interpretation of loss reduction and other calculations. The devised technique was tested on two test distribution systems of varying size and complexity and validated by comparison with the exhaustive iterative method (EIM) and recently published results. Results showed that the proposed technique can provide an optimal solution with less computation.

关键词: Distributed generation (DG),  Distribution networks,  Loss reduction,  DG optimization,  Energy loss curves 
[1] J. A. Laghari, H. Mokhlis, M. Karimi, A. H. A. Bakar, Hasmaini Mohamad. A new technique for islanding operation of distribution network connected with mini hydro[J]. Front. Inform. Technol. Electron. Eng., 2015, 16(5): 418-427.