Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering)  2011, Vol. 12 Issue (2): 103-120    DOI: 10.1631/jzus.A1000067
Civil Engineering     
Response of a transmission tower-line system at a canyon site to spatially varying ground motions
Hong-nan Li, Feng-long Bai, Li Tian, Hong Hao
State Key Laboratory of Coastal and Offshore Engineering, Dalian University of Technology, Dalian 116024, China, School of Civil and Resource Engineering, University of Western Australia, WA 6009, Australia
Download:     PDF (0 KB)     
Export: BibTeX | EndNote (RIS)      

Abstract  Collapses of transmission towers were often observed in previous large earthquakes such as the Chi-Chi earthquake in Taiwan and Wenchuan earthquake in Sichuan, China. These collapses were partially caused by the pulling forces from the transmission lines generated from out-of-phase responses of the adjacent towers owing to spatially varying earthquake ground motions. In this paper, a 3D finite element model of the transmission tower-line system is established considering the geometric nonlinearity of transmission lines. The nonlinear responses of the structural system at a canyon site are analyzed subjected to spatially varying ground motions. The spatial variations of ground motion associated with the wave passage, coherency loss, and local site effects are given. The spatially varying ground motions are simulated stochastically based on an empirical coherency loss function and a filtered Tajimi-Kanai power spectral density function. The site effect is considered by a transfer function derived from 1D wave propagation theory. Compared with structural responses calculated using the uniform ground motion and delayed excitations, numerical results indicate that seismic responses of transmission towers and power lines are amplified when considering spatially varying ground motions including site effects. Each factor of ground motion spatial variations has a significant effect on the seismic response of the structure, especially for the local site effect. Therefore, neglecting the earthquake ground motion spatial variations may lead to a substantial underestimation of the response of transmission tower-line system during strong earthquakes. Each effect of ground motion spatial variations should be incorporated in seismic analysis of the structural system.

Key wordsTransmission tower-line system      Canyon site      Spatially varying ground motions      Coherency loss      Local site effect     
Received: 25 February 2010      Published: 08 February 2011
CLC:  TU393.3  
Cite this article:

Hong-nan Li, Feng-long Bai, Li Tian, Hong Hao. Response of a transmission tower-line system at a canyon site to spatially varying ground motions. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2011, 12(2): 103-120.

URL:

http://www.zjujournals.com/xueshu/zjus-a/10.1631/jzus.A1000067     OR     http://www.zjujournals.com/xueshu/zjus-a/Y2011/V12/I2/103

[1] Ming-min Ding, Bin Luo, Zheng-xing Guo, Jie Pan. Integral tow-lifting construction technology of a tensile beam-cable dome[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2015, 16(12): 935-950.
[2] Jin-yu Zhou, Wu-jun Chen, Bing Zhao, Zhen-yu Qiu, Shi-lin Dong. Distributed indeterminacy evaluation of cable-strut structures: formulations and applications[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2015, 16(9): 737-748.
[3] Wu-jun Chen, Jin-yu Zhou, Jun-zhao Zhao. Computational methods for the zero-stress state and the pre-stress state of tensile cable-net structures[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2014, 15(10): 813-828.
[4] Hui Wu, Bo-qing Gao, Qiang Chen. Load-carrying capacity and practical calculation method for hollow cylinder joints connected with H-shaped beams[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2012, 13(3): 174-181.
[5] Zhao-dong Xu, Deng-xiang Wang, Ke-yi Wu. Simulation of stochastic wind field for large complex structures based on modified Fourier spectrum[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2011, 12(3): 238-246.
[6] Jun-jie LUO, Da-jian HAN. 3D wind-induced response analysis of a cable-membrane structure[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2009, 10(3): 337-344.
[7] ZHANG Li-mei, CHEN Wu-jun, DONG Shi-lin. Initial pre-stress finding procedure and structural performance research for Levy cable dome based on linear adjustment theory[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2007, 8(9): 1366-1372.