Please wait a minute...
Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering)  2009, Vol. 10 Issue (11): 1595-1600    DOI: 10.1631/jzus.A0820742
Mechanics and Mechanical Engineering     
Development of a linear compressor for two-stage pulse tube cryocoolers
Peng-da YAN, Wei-li GAO, Guo-bang CHEN
Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027, China
Download:     PDF (0 KB)     
Export: BibTeX | EndNote (RIS)      

Abstract  A valveless linear compressor was built up to drive a self-made two-stage pulse tube cryocooler. With a designed maximum swept volume of 60 cm3, the compressor can provide the cryocooler with a pressure volume (PV) power of 400 W. Preliminary measurements of the compressor indicated that both an efficiency of 35%~55% and a pressure ratio of 1.3~1.4 could be obtained. The two-stage pulse tube cryocooler driven by this compressor achieved the lowest temperature of 14.2 K.

Key wordsLinear compressor      Linear motor      Pulse tube cryocooler     
Received: 23 October 2008     
CLC:  TB652  
Cite this article:

Peng-da YAN, Wei-li GAO, Guo-bang CHEN. Development of a linear compressor for two-stage pulse tube cryocoolers. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2009, 10(11): 1595-1600.

URL:

http://www.zjujournals.com/xueshu/zjus-a/10.1631/jzus.A0820742     OR     http://www.zjujournals.com/xueshu/zjus-a/Y2009/V10/I11/1595

[1] Jiu-ce Sun, Marc Dietrich, Li-min Qiu, Guenter Thummes. Operating characteristics of a single-stage Stirling-type pulse tube cryocooler with high cooling power at liquid nitrogen temperatures[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2015, 16(7): 577-585.
[2] Kai Fang, Li-min Qiu, Xiao Jiang, Zhi-hua Gan, Ning-xiang Tong. Temperature inhomogeneity in high capacity pulse tube cryocoolers[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2015, 16(11): 910-921.
[3] Zhuo-pei Li, Yan-long Jiang, Zhi-hua Gan, Li-min Qiu, Jie Chen. Performance of a precooled 4 K Stirling type high frequency pulse tube cryocooler with Gd2O2S[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2014, 15(7): 508-516.
[4] Zhi-hua Gan, Long-yi Wang, Sheng-ying Zhao, Yu-jing Song, Wei-wei Wang, Yi-nong Wu. Acoustic impedance characteristics of linear compressors[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2013, 14(7): 494-503.
[5] Zhi-hua GAN, Zhuo-pei LI, Jie CHEN, Li DAI, Li-min QIU. Design and preliminary experimental investigation of a 4 K Stirling-type pulse tube cryocooler with precooling[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2009, 10(9): 1277-1284.