Abstract  Golay codes are the most practical code in coded ultrasound imaging systems. But the trade-off for perfect range sidelobe cancellation is the requirement for two firings, thus resulting in motion-dependent decoding errors. In view of this, we propose a new scheme using the simultaneous emission of code pairs. The code pair is allocated to different elements of an aperture and transmitted simultaneously. The process of separating the code pair from the echo received is based on the orthogonality of the code pair. At last the autocorrelation functions of the individual Golay codes are added together. The simultaneous emission of code pairs instead of two firings recovers the frame rate loss, and eliminates the motion-dependent decoding error. Our theoretical analysis and simulations show that the scheme can be used to eliminate the tissue motion effects.

Key wordsCoded ultrasound      Golay codes      Tissue motion      Ultrasonic imaging     
Received: 15 June 2009      Published: 02 June 2010
CLC:  TH77  
Fund:  Project supported by the National Natural Science Foundation of China (Nos.  60772147  and  60871060),  and  the  Science  and  Technology
Planning Project of Shenzhen City, China (No. JC200903120129A)
Cite this article:

Cheng Jin, Si-ping Chen, Zheng-di Qin, Tian-fu Wang. A new scheme of coded ultrasound using Golay codes. Front. Inform. Technol. Electron. Eng., 2010, 11(6): 476-480.

URL:

http://www.zjujournals.com/xueshu/fitee/10.1631/jzus.C0910353     OR     http://www.zjujournals.com/xueshu/fitee/Y2010/V11/I6/476


A new scheme of coded ultrasound using Golay codes

Golay codes are the most practical code in coded ultrasound imaging systems. But the trade-off for perfect range sidelobe cancellation is the requirement for two firings, thus resulting in motion-dependent decoding errors. In view of this, we propose a new scheme using the simultaneous emission of code pairs. The code pair is allocated to different elements of an aperture and transmitted simultaneously. The process of separating the code pair from the echo received is based on the orthogonality of the code pair. At last the autocorrelation functions of the individual Golay codes are added together. The simultaneous emission of code pairs instead of two firings recovers the frame rate loss, and eliminates the motion-dependent decoding error. Our theoretical analysis and simulations show that the scheme can be used to eliminate the tissue motion effects.

关键词: Coded ultrasound,  Golay codes,  Tissue motion,  Ultrasonic imaging 
No related articles found!