Please wait a minute...
Front. Inform. Technol. Electron. Eng.  2011, Vol. 12 Issue (3): 239-249    DOI: 10.1631/jzus.C1000043
    
Using concurrent lines in central catadioptric camera calibration
Lei Zhang, Xin Du, Ji-lin Liu
Department of Information Science and Electronic Engineering, Zhejiang University, Hangzhou 310027, China
Using concurrent lines in central catadioptric camera calibration
Lei Zhang, Xin Du, Ji-lin Liu
Department of Information Science and Electronic Engineering, Zhejiang University, Hangzhou 310027, China
 全文: PDF(408 KB)  
摘要: Central catadioptric cameras have been extensively adopted in robotics and surveillance due to their extensive field of view. To attain precise 3D information in these applications, it is important to calibrate the catadioptric cameras accurately. The existing calibration techniques either require prior knowledge of the mirror types, or highly depend on a conic estimation procedure, which might be ruined if there are only small portions of the conic visible on calibration images. In this paper, we design a novel planar pattern with concurrent lines as a calibration rig, which is more robust in conic estimation since the relationship among lines is taken into account. Based on the line properties, we propose a rough-to-fine approach suitable for the new planar pattern to calibrate central catadioptric cameras. This method divides the nonlinear optimization calibration problem into several linear sub-problems that are much more robust against noise. Our calibration method can estimate intrinsic parameters and the mirror parameter simultaneously and accurately, without a priori knowledge of the mirror type. The performance is demonstrated by both simulation and a real hyperbolic catadioptric imaging system.
关键词: CatadioptricCalibrationConcurrent linesConic estimation    
Abstract: Central catadioptric cameras have been extensively adopted in robotics and surveillance due to their extensive field of view. To attain precise 3D information in these applications, it is important to calibrate the catadioptric cameras accurately. The existing calibration techniques either require prior knowledge of the mirror types, or highly depend on a conic estimation procedure, which might be ruined if there are only small portions of the conic visible on calibration images. In this paper, we design a novel planar pattern with concurrent lines as a calibration rig, which is more robust in conic estimation since the relationship among lines is taken into account. Based on the line properties, we propose a rough-to-fine approach suitable for the new planar pattern to calibrate central catadioptric cameras. This method divides the nonlinear optimization calibration problem into several linear sub-problems that are much more robust against noise. Our calibration method can estimate intrinsic parameters and the mirror parameter simultaneously and accurately, without a priori knowledge of the mirror type. The performance is demonstrated by both simulation and a real hyperbolic catadioptric imaging system.
Key words: Catadioptric    Calibration    Concurrent lines    Conic estimation
收稿日期: 2010-03-02 出版日期: 2011-03-09
CLC:  TP317.4  
服务  
把本文推荐给朋友
加入引用管理器
E-mail Alert
RSS
作者相关文章  
Lei Zhang
Xin Du
Ji-lin Liu

引用本文:

Lei Zhang, Xin Du, Ji-lin Liu. Using concurrent lines in central catadioptric camera calibration. Front. Inform. Technol. Electron. Eng., 2011, 12(3): 239-249.

链接本文:

http://www.zjujournals.com/xueshu/fitee/CN/10.1631/jzus.C1000043        http://www.zjujournals.com/xueshu/fitee/CN/Y2011/V12/I3/239

[1] Hao ZHU , Qing WANG , Jingyi YU. Light field imaging: models, calibrations, reconstructions, and applications[J]. Front. Inform. Technol. Electron. Eng., 2017, 18(9): 1236-1249.
[2] Yuan-hui Zhang, Wei Wei, Dan Yu, Cong-wei Zhong. A tracking and predicting scheme for ping pong robot[J]. Front. Inform. Technol. Electron. Eng., 2011, 12(2): 110-115.