Front. Inform. Technol. Electron. Eng.  2018, Vol. 19 Issue (11): 1420-1431    
    
Improved three-vector based dead-beat model predictive direct power control strategy for grid-connected inverters
Chen-wen CHENG, Heng NIAN , Long-qi LI
College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
Improved three-vector based dead-beat model predictive direct power control strategy for grid-connected inverters
Chen-wen CHENG, Heng NIAN , Long-qi LI
College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
 全文: PDF 
摘要: Since only one inverter voltage vector is applied during each duty cycle, traditional model predictive direct power
control (MPDPC) for grid-connected inverters (GCIs) results in serious harmonics in current and power. Moreover, a high sam-
pling frequency is needed to ensure satisfactory steady-state performance, which is contradictory to its long execution time due to
the iterative prediction calculations. To solve these problems, a novel dead-beat MPDPC strategy is proposed, using two active
inverter voltage vectors and one zero inverter voltage vector during each duty cycle. Adoption of three inverter vectors ensures a
constant  switching  frequency.  Thus,  smooth  steady-state  performance  of  both  current  and  power  can  be obtained.  Unlike  the
traditional three-vector based MPDPC strategy, the proposed three vectors are selected based on the power errors rather than the
sector where the grid voltage vector is located, which ensures that the duration times of the selected vectors are positive all the time.
Iterative calculations of the cost function in traditional predictive control are also removed, which makes the proposed strategy
easy to implement on digital signal processors (DSPs) for industrial applications. Results of experiments based on a 1 kW inverter
setup validate the feasibility of the proposed three-vector based dead-beat MPDPC strategy.
关键词: Grid-connected  inverter  Model  predictive  control Direct  power  control  Three  vectors  Constant  switching  fre-
quency
Power errors    
Abstract: Since only one inverter voltage vector is applied during each duty cycle, traditional model predictive direct power
control (MPDPC) for grid-connected inverters (GCIs) results in serious harmonics in current and power. Moreover, a high sam-
pling frequency is needed to ensure satisfactory steady-state performance, which is contradictory to its long execution time due to
the iterative prediction calculations. To solve these problems, a novel dead-beat MPDPC strategy is proposed, using two active
inverter voltage vectors and one zero inverter voltage vector during each duty cycle. Adoption of three inverter vectors ensures a
constant  switching  frequency.  Thus,  smooth  steady-state  performance  of  both  current  and  power  can  be obtained.  Unlike  the
traditional three-vector based MPDPC strategy, the proposed three vectors are selected based on the power errors rather than the
sector where the grid voltage vector is located, which ensures that the duration times of the selected vectors are positive all the time.
Iterative calculations of the cost function in traditional predictive control are also removed, which makes the proposed strategy
easy to implement on digital signal processors (DSPs) for industrial applications. Results of experiments based on a 1 kW inverter
setup validate the feasibility of the proposed three-vector based dead-beat MPDPC strategy.
Key words: Grid-connected     inverter         Model     predictive     control    Direct     power     control         Three     vectors         Constant     switching     fre-
quency
   Power errors
收稿日期: 2016-12-29 出版日期: 2019-06-13
服务  
把本文推荐给朋友
加入引用管理器
E-mail Alert
RSS
作者相关文章  
Chen-wen CHENG
Heng NIAN
Long-qi LI

引用本文:

Chen-wen CHENG, Heng NIAN , Long-qi LI. Improved three-vector based dead-beat model predictive direct power control strategy for grid-connected inverters. Front. Inform. Technol. Electron. Eng., 2018, 19(11): 1420-1431.

链接本文:

http://www.zjujournals.com/xueshu/fitee/CN/        http://www.zjujournals.com/xueshu/fitee/CN/Y2018/V19/I11/1420

[1] Shafqat Ullah KHAN, M. K. A. RAHIM, Liaqat ALI. Correction of array failure using grey wolf optimizer hybridized with an interior point algorithm[J]. Front. Inform. Technol. Electron. Eng., 2018, 19(9): 1191-1202.
[2] Qun-wei XU, Jin-xiang ZHAN, Long XIAO, Guo-zhu CHEN. A multi-modular shunt active power filter system and its novel fault-tolerant strategy based on split-phase control and real-time bus communication[J]. Front. Inform. Technol. Electron. Eng., 2018, 19(9): 1166-1179.
[3] Meng-zhou GAO], Dong-qin FENG. Stochastic stability analysis of networked control systems with random cryptographic protection under random zero-measurement attacks[J]. Front. Inform. Technol. Electron. Eng., 2018, 19(9): 1098-1111.
[4] Lan-jun LIU, Jian-fen LI , Lin ZHOU, Peng ZHAI, Hao ZHAO, Jiu-cai JIN, Zhi-chao LV. An underwater acoustic direct sequence spread spectrum communication system using dual spread spectrum code[J]. Front. Inform. Technol. Electron. Eng., 2018, 19(8): 972-983.
[5] Bo LI, Yuan-xin XU, Shuang-shuang FAN, Wen XU. Underwater docking of an under-actuated autonomous underwater vehicle: system design and control implementation[J]. Front. Inform. Technol. Electron. Eng., 2018, 19(8): 1024-1041.
[6] Xin CHEN, Ding WANG, Rui-rui LIU, Jie-xin YIN, Ying WU. Structural total least squares algorithm for locating multiple disjoint sources based on AOA/TOA/FOA in the presence of system error[J]. Front. Inform. Technol. Electron. Eng., 2018, 19(7): 917-936.
[7] Zai-sheng PAN , Xuan-hao ZHOU , Peng CHEN. Development and application of a neural network based coating weight control system for a hot-dip galvanizing line [J]. Front. Inform. Technol. Electron. Eng., 2018, 19(7): 834-846.
[8] Bo YU, Ying FANG, Qiang YANG, Yong TANG, Liu LIU. A survey of malware behavior description and analysis[J]. Front. Inform. Technol. Electron. Eng., 2018, 19(5): 583-603.
[9] Meng WANG, Jia-qiang YANG, Xiang ZHANG, Chang-sheng ZHU. Accurate two-degree-of-freedom discrete-time current controller design for PMSM using complex vectors[J]. Front. Inform. Technol. Electron. Eng., 2018, 19(4): 569-581.
[10] Yi-qi XIE, Zhi-guo YU, Yang FENG, Lin-na ZHAO, Xiao-feng GU. A multistandard and resource-efficient Viterbi decoder for a multimode communication system[J]. Front. Inform. Technol. Electron. Eng., 2018, 19(4): 536-543.
[11] Yun-zheng TAO, Chun-yan WU, Yu-zhen HUANG, Ping ZHANG. A projected gradient based game theoretic approach for multi-user power control in cognitive radio network[J]. Front. Inform. Technol. Electron. Eng., 2018, 19(3): 367-378.
[12] Xu-guang ZUO, Lu YU. Long-term prediction for hierarchical-B-picture-based coding of video with repeated shots[J]. Front. Inform. Technol. Electron. Eng., 2018, 19(3): 459-470.
[13] Lu CHEN, Ding-zhu WEN, Cai-jun ZHONG, Guan-ding YU. Hybrid full-/half-duplex cellular networks: user admission and power control[J]. Front. Inform. Technol. Electron. Eng., 2018, 19(3): 379-387.
[14] Pritesh SHAH, Sudhir AGASHE, Anand J. KULKARNI. Design of a fractional PI λ D μ controller using the cohort intelligence method[J]. Front. Inform. Technol. Electron. Eng., 2018, 19(3): 437-445.
[15] Muhammad Asif Zahoor RAJA, Muhammad Saeed ASLAM , Naveed Ishtiaq CHAUDHARY. Bio-inspired heuristics hybrid with interior-point method for active noise control systems without identification of secondary path[J]. Front. Inform. Technol. Electron. Eng., 2018, 19(2): 246-259.