J Zhejiang Univ (Med Sci)  2018, Vol. 47 Issue (1): 64-70    DOI: 10.3785/j.issn.1008-9292.2018.02.09
    
Experimental factors affecting in vitro recovery of puerarin in microdialysis
ZHAN Shuyu1(),RUAN Yu'er1,LIU Guoqiang1,DING Baoyue1,SHAO Qing2
1. Department of Pharmacy, Medical College of Jiaxing University, Jiaxing 314033, Zhejiang Province, China
2. Department of Traditional Chinese Medicine Science and Engineering, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou 310058, China
Download: HTML( 2 )   PDF(1089KB)
Export: BibTeX | EndNote (RIS)      

Abstract  

Objective: To analyze experimental factors affecting in vitro recovery of puerarin in microdialysis. Methods: Puerarin concentration in microdialysate samples was determined by high performance liquid chromatography. The methods of direct dialysis, retrodialysis and the zero-net flux were used to calculate in vitro recovery, respectively. The effects of perfusate composition, the analyte concentration, perfusate flow rate, medium temperature and stir rates of the dialysis medium on recovery were investigated. Results: There were significant differences in the recovery values among direct dialysis, retrodialysis and zero-net flux methods. The recovery for 0.9% NaCl solution, Ringer's solution, PBS and anticoagulant dextrose solution as perfusate fluid were (71.25±2.36)%, (73.48±1.41)%, (68.50±2.43)% and (74.98±1.16)%, respectively. The composition of perfusate fluid had significant influence on the recovery(P < 0.01). At the same flow rate, recovery was independent of the analyte concentration. At the same concentration, the recovery was decrease with the increasing flow rate in an exponential relationship. The recovery increased with the raising temperature and stir rate of the dialysis medium, and the recovery remained stable when the stir rate reached above 200 rpm. Conclusion: A study method for in vitro recovery of puerarin in microdialysis has been established, and the recovery of puerarin is affected by calculating methods, perfusate fluids, flow rate, medium temperature and stir rate, but not affected by analyte concentrations.



Key wordsRetrieving rate      Puerarin/pharmacokinetics      Microdialysis      Chromatography, high pressure liquid     
Received: 10 June 2017      Published: 12 June 2018
CLC:  R969.1  
Cite this article:

ZHAN Shuyu,RUAN Yu'er,LIU Guoqiang,DING Baoyue,SHAO Qing. Experimental factors affecting in vitro recovery of puerarin in microdialysis. J Zhejiang Univ (Med Sci), 2018, 47(1): 64-70.

URL:

http://www.zjujournals.com/med/10.3785/j.issn.1008-9292.2018.02.09     OR     http://www.zjujournals.com/med/Y2018/V47/I1/64


葛根素微透析体外回收率测定及其影响因素研究

目的: 建立葛根素微透析体外回收率的测定方法,考察影响回收率的有关因素。方法: 采用高效液相色谱法测定微透析样品中葛根素的浓度,利用增量法、减量法和零净通量法计算探针的相对回收率,并考察灌流液成分、外液浓度、灌流速度、介质温度和搅拌速率对回收率的影响。结果: 对于同一探针,三种计算方法得出的回收率存在差异。采用等渗氯化钠溶液、林格液、PBS和葡萄糖溶液为灌流液时,得到的回收率分别为(71.25±2.36)%、(73.48±1.41)%、(68.50±2.43)%和(74.98±1.16)%,差异有统计学意义(P < 0.01);在同一灌流速度下,探针回收率在外液葛根素浓度为0.2~25 μg/mL的范围内差异无统计学意义(P > 0.05);在同一浓度下,探针的回收率随灌流速度的增加呈指数下降;在25~40℃范围内,探针回收率随介质温度升高而增大;探针的回收率随着搅拌速率的增加而增大,当速率达到200转/min时,回收率达到一个相对稳定的值。结论: 本研究建立了葛根素微透析体外回收率的测定方法。葛根素微透析探针体外回收率与介质中葛根素浓度无关,而受计算方法、灌流液成分、灌流速度、介质温度和搅拌速率等因素的影响。


关键词: 回收率,  葛根素/药代动力学,  微透析,  色谱法, 高压液相 
(n=6,$\bar x \pm s$,%)
测定方法 探针1 探针2 探针3
增量法 73.54±1.42 73.48±1.41 80.88±1.25
减量法 70.22±0.40 69.49±1.22 67.78±0.31
F 24.646 620.731 27.534
P <0.01 <0.01 <0.01
Tab 1 Probe relative recovery determined by gain and loss methods
Fig 1 Zero-net flux plot for estimating probe relative recovery of puerarin from the microdialysis probe (n=6)
(n=6,$\bar x \pm s$,%)
外液浓度
(μg/mL)
2 μL/min 6 μL/min 10 μL/min
0.20 72.38±1.41 37.99±0.82 25.30±1.26
1.00 72.61±1.49 36.66±0.17 27.44±0.18
5.00 72.51±1.15 36.99±0.33 25.59±0.05
10.00 73.54±1.42 36.70±0.43 25.35±0.08
15.00 73.24±1.20 36.67±0.23 25.69±0.60
20.00 74.49±1.14 36.93±0.23 26.01±0.09
25.00 73.25±0.94 38.29±0.36 24.66±0.46
Tab 2 Effect of external concentration on probe relative recovery at different dialysate flow rates
Fig 2 Effect of dialysate flow rate on probe relative recovery(n=6)
Fig 3 Effect of medium temperature on probe relative recovery(n=6)
Fig 4 Effect of stir rate on probe relative recovery(n=6)
[1]   SAYLOR R A , LUNTE S M . A review of microdialysis coupled to microchip electrophoresis for monitoring biological events[J]. J Chromatogr A, 2015, 1382 48- 64
doi: 10.1016/j.chroma.2014.12.086
[2]   季亚军 . 微透析取样技术在中药体内分析中的应用研究进展[J]. 实用药物与临床, 2012, 15 (1): 46- 48
JI Yajun . Research progress in application of microdialysis in analysis of Chinese medicine in vivo[J]. Practical Pharmacy and Clinical Remedies, 2012, 15 (1): 46- 48
[3]   AZEREDO F J , DALLA C T , DERENDORF H . Role of microdialysis in pharmacokinetics and pharmacodynamics:current status and future directions[J]. Clin Pharmacokinet, 2014, 53 (3): 205- 212
doi: 10.1007/s40262-014-0131-8
[4]   曹柳, 辛贵忠, 闻晓东 et al. 微透析及其联用技术在中药研究中的应用[J]. 中国新药杂志, 2012, 21 (6): 605- 610
CAO Liu , XIN Guizhong , WEN Xiaodong et al. Application of microdialysis and its hyphenated techniques in studies of traditional Chinese medicines[J]. Chinese Journal of New Drugs, 2012, 21 (6): 605- 610
[5]   CHIANG M H , CHANG L W , WANG J W et al. Herb-drug pharmacokinetic interaction of a traditional chinese medicine jia-wei-xiao-yao-san with 5-fluorouracil in the blood and brain of rat using microdialysis[J]. Evid Based Complement Alternat Med, 2015, 2015 729679
[6]   KHO C M , ENCHE A R S K , AHMAD Z A et al. A review on microdialysis calibration methods:the theory and current related ffforts[J]. Mol Neurobiol, 2017, 54 (5): 3506- 3527
doi: 10.1007/s12035-016-9929-8
[7]   鄢欢, 曹玲娟, 李焕德 . 提高微透析探针回收率方法的研究进展[J]. 中南药学, 2014, 12 (2): 140- 144
YAN Huan , CAO Linjuan , LI Huande . Research progress in microdialysis recovery[J]. Central South Pharmacy, 2014, 12 (2): 140- 144
doi: 10.7539/j.issn.1672-2981.2014.02.012
[8]   王丹, 刘春生, 吕亚丽 et al. 葛根素微透析线性探针相对回收率影响因素的研究[J]. 国际药学研究杂志, 2011, 38 (5): 390- 393
WANG Dan , LIU Chunsheng , LYU Yali et al. Study on influence factors of microdialysis linear probe recovery for puerarin[J]. Journal of International Pharmaceutical Research, 2011, 38 (5): 390- 393
[9]   WANG W Y , YAO C , SHAO Y F et al. Determination of puerarin in rabbit aqueous humor by liquid chromatography tandem mass spectrometry using microdialysis sampling after topical administration of puerarin PAMAM dendrimer complex[J]. J Pharm Biomed Anal, 2011, 56 (4): 825- 829
doi: 10.1016/j.jpba.2011.07.017
[10]   韩进, 范红晶, 杨洁红 et al. 脑缺血再灌注大鼠灌胃养阴通脑颗粒后主要成分葛根素的药动学研究[J]. 中国中医急症, 2016, 25 (6): 945- 948
HAN Jin , FAN Hongjing , YANG Jiehong et al. Pharmacokinetics research of puerarin on cerebral ischemia-reperfusion rats after intragastric administration of yangyin tongnao decoction by brain-jugular vein dual-channel microdialysis[J]. Journal of Emergency in Traditional Chinese Medicine, 2016, 25 (6): 945- 948
[11]   L?NNROTH P , JANSSON P A , SMITH U . A microdialysis method allowing characterization of intercellular water space in humans[J]. Am J Physiol, 1987, 253 (2 Pt 1): E228- E231
[12]   YANG H , PETERS J L , ALLEN C et al. A theoretical description of microdialysis with mass transport coupled to chemical events[J]. Anal Chem, 2000, 72 (9): 2042- 2049
doi: 10.1021/ac991186r
[13]   KHAN F , PHARO A , LINDSTAD J K et al. Effect of perfusion fluids on recovery of inflammatory mediators in microdialysis[J]. Scand J Immunol, 2015, 82 (5): 467- 475
doi: 10.1111/sji.2015.82.issue-5
[14]   SCHUCK V J , RINAS I , DERENDORF H . In vitro microdialysis sampling of docetaxel[J]. J Pharm Biomed Anal, 2004, 36 (4): 807- 813
doi: 10.1016/j.jpba.2004.07.007
[15]   MARTíNEZ M S M , HURTADO B G , GANDARILLAS C I C et al. In vitro study of experimental factors affecting the microdialysis results[J]. Analytica chimica acta, 2002, 459 143- 150
doi: 10.1016/S0003-2670(02)00104-6
[16]   张恒义, 施弘毅, 王恩禹 . 环境温度对单胺类神经递质微透析探针回收率的影响[J]. 浙江大学学报(医学版), 2009, 38 (3): 271- 275
ZHANG Hengyi , SHI Hongyi , WANG Enyu . Effect of environment temperature on the recovery of microdialysis probe for monoamine neurotransmitter[J]. Journal of Zhejiang University (Medical Sciences), 2009, 38 (3): 271- 275
[1] ZHANG Xiang-qun, WU Ling-hua,CHEN Fang-jun, ZHANG Yi, CHEN Lu. Quantitative determination of voglibose contents in its tablets with high-performance liquid chromatography-mass spectrometry[J]. J Zhejiang Univ (Med Sci), 2014, 43(2): 141-144.
[2] Liu Ziyi, Chen Shuqing, Zhang Hongming, et al. STUDY ON THE EXISTENCE, CONTENT AND BIOLOGICAL ACTIVITY OF ESTRADIOL IN RAPE BEE POLLEN[J]. J Zhejiang Univ (Med Sci), 1993, 22(2): 49-52.