Assessment of left ventricular twist in type 2 diabetes mellitus by using two-dimensional ultrasound speckle tracking imaging |
1. Department of Ultrasonography, Zhejiang Hospital, Hangzhou 310013, China; 2. Department of Ultrasonography, First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310003, China |
|
|
Abstract Objective: To evaluate the left ventricular twist characteristics in patients with type 2 diabetes by using two-dimensional speckle tracking imaging(STI). Methods: Ninety-three patients with type 2 diabetes admitted in Zhejiang Hospital from May 2012 to September 2013 were enrolled. According to left ventricular ejection fraction(LVEF), patients were divided into two groups: normal left ventricular systolic function group(group A, LVEF≥0.50, n=46 )and abnormal left ventricular systolic function group (group B, LVEF < 0.50, n=47 ). Forty-six healthy subjects were selected as normal controls. STI was applied to quantitatively analyze the left ventricular twist. Correlation of the peak of left ventricular twist angle (Peaktw), aortic valve closure time twist angle (AVCtw), and mitral valve opening time twist angle (MVOtw)with LVEF, Tei index, E/A, and E/e was evaluated. Consistency check for STI was conducted to assess its stability and reliability. Results: The Peaktw, AVCtw, and MVOtw in group A were significantly elevated than those in normal controls ( Ps < 0.05). The Peaktw, AVCtw, and MVOtw in group B was lower than those in normal controls and group A ( Ps <0.05). In diabetic patients, the Peaktw, AVCtw, MVOtw were positively correlated with LVEF (r=0.968, 0.966, 0.938; Ps< 0.05)and E/A (r=0.798, 0.790, 0.788; Ps <0.05), and were negatively correlated with Tei index (r=-0. 834, -0.811, -0.797; Ps< 0.05)and E/e (r=-0.823, -0.805, -0.771; Ps <0.05).The agreement between measurers and within measurers of Peaktw was satisfactory(between measurers: R=0.957, bias=-0.1, 95% consistency limit=-2.8-2.7; within measurer: R=0.964, bias=-0.2, 95% consistency limits=-2.7-2.2). Conclusion: STI can be used for early recognition of abnormal changes of cardiac function in type 2 diabetic mellitus patients, with high stability and reliability.
|
Received: 30 October 2013
Published: 18 April 2014
|
Corresponding Authors:
HUANG Jing-yuan,E-mail: dhjh1981@chinaren.com
|
超声二维斑点追踪显像技术评价2型糖尿病患者左心室功能的临床价值
目的:应用超声二维斑点追踪显像(STI)技术探讨2型糖尿病患者左心室心肌扭转运动的特点。方法:选取2012年5月至2013年9月在浙江医院就诊的93例2型糖尿病患者,根据左心室射血分数(LVEF)分为心功能正常组(LVEF≥0.50,46例)和心功能衰竭组(LVEF<0.50,47例)。另设正常对照组(n=46)。应用STI定量分析三组受检者的左心室扭转情况,分析左心室扭转角度峰值(Peaktw)、主动脉瓣关闭时间点扭转角度(AVCtw)、二尖瓣开放时间点扭转角度(MVOtw)等指标与常规超声心动图检测指标LVEF、Tei指数、二尖瓣口E峰值/二尖瓣口A峰值(E/A)比值、二尖瓣口血流频谱E峰值/组织多普勒二尖瓣环运动e峰值(E/e)比值间的相关性;并进行一致性检验以评价STI的稳定性及可靠性。 结果:心功能正常组的Peaktw、AVCtw、MVOtw均高于正常对照组(均P<0.05),心功能衰竭组Peaktw、AVCtw、MVOtw均低于心功能正常组和正常对照组(均P<0.05)。糖尿病患者的Peaktw、AVCtw、MVOtw与LVEF呈正相关(r=0.968、0.966、0.938,均P<0.05),与Tei指数呈负相关(r=-0. 834、-0.811、-0.797,均P<0.05),与E/A比值呈正相关(r=0.798、0.790、0.788,均P<0.05),与E/e比值呈负相关(r=-0.823、-0.805、-0.771,均P<0.05)。一致性检验显示Peaktw在检测者间的R=0.957, 偏倚为-0.1 ,95%一致性界限为-2.8~2.7;在检测者内的R=0.964,偏倚为-0.2, 95%一致性界限为-2.7 ~ 2.2。结论:STI能够早期识别2型糖尿病患者的心功能异常变化,检测技术具有较高的稳定性及可靠性。
关键词:
心室/超声检查,
心室/病理学,
异常扭转/超声检查,
糖尿病, 2型/并发症,
心室功能, 左,
超声心动描记术
|