高温电连接器绝缘件失效分析
钟立强,李齐备,郭鸿杰,钱萍,陈文华

Failure analysis of insulation part for high-temperature electrical connector
Liqiang ZHONG,Qibei LI,Hongjie GUO,Ping QIAN,Wenhua CHEN
表2 劣化实验前后电阻测量点的绝缘电阻 (GΩ)
Table 2 Insulation resistance of resistance measuring points before and after deterioration test
序号实验前实验后变化值
1-1139.77.5132.2
1-2118.711.3107.4
1-3131.36.9124.4
1-4142.17.6134.5
1-5146.910.9136.0
1-6125.17.9117.2
2-1141.310.9130.4
2-2133.27.4125.8
2-3143.17.3135.8
2-4134.18.7125.4
2-5146.78.5138.2
2-6181.321.4159.9
3-1177.415.1162.3
3-2163.717.1146.6
3-3147.810.9136.9
3-4163.717.7146.0
3-5167.312.9154.4
3-6158.716.9141.8
4-1171.17.2163.9
4-2127.68.2119.4
4-3167.931.3136.6
4-4169.311.6157.7
4-5173.213.4159.8
4-6168.912.5156.4