考虑围岩岩性影响的高岩温隧道围岩-衬砌界面接触热阻计算方法
|
|
崔光耀,何子阳,王道远,石文昊
|
Thermal contact resistance calculation at rock-lining interface in high-temperature tunnels with consideration of surrounding rock lithology
|
|
Guangyao CUI,Ziyang HE,Daoyuan WANG,Wenhao SHI
|
|
| 表 5 界面接触热阻计算结果与理论结果的相对误差 |
| Tab.5 Relative error between calculated and theoretical interfacial thermal contact resistance |
|
| 分组 | R/(10−3 m2·K·W−1) | δ/% | | 理论结果 | 计算结果 | | C25-玄武岩 | 3.789 | 4.076 | 7.587 | | C25-页岩 | 4.332 | 4.458 | 2.906 | | C25-花岗岩 | 5.120 | 4.883 | −4.636 | | C25-砂岩 | 6.866 | 6.539 | −4.766 | | C25-泥岩 | 9.134 | 8.534 | −6.563 | | C30-玄武岩 | 3.618 | 3.864 | 6.783 | | C30-页岩 | 4.375 | 4.331 | −1.005 | | C30-花岗岩 | 4.884 | 4.628 | −5.242 | | C30-砂岩 | 6.686 | 6.072 | −9.194 | | C30-泥岩 | 8.441 | 7.982 | −5.435 | | C35-玄武岩 | 3.661 | 3.567 | −2.578 | | C35-页岩 | 3.908 | 4.203 | 7.572 | | C35-花岗岩 | 4.604 | 4.331 | −5.931 | | C35-砂岩 | 6.148 | 5.562 | −9.528 | | C35-泥岩 | 7.792 | 7.515 | −3.549 | | C40-玄武岩 | 3.588 | 3.439 | −4.143 | | C40-页岩 | 3.440 | 3.736 | 8.604 | | C40-花岗岩 | 3.958 | 4.076 | 2.971 | | C40-砂岩 | 5.699 | 5.477 | −3.894 | | C40-泥岩 | 7.532 | 7.048 | −6.424 |
|
|
|