基于多子空间加权移动窗主成分分析的全厂流程早期故障检测
宋易盟,宋冰,侍洪波,康永波

Multiple subspace weighted moving window PCA for plant-wide process incipient fault detection
Yimeng SONG,Bing SONG,Hongbo SHI,Yongbo KANG
表 2 故障工况的误报率和故障检测率
Tab.2 False alarm and fault detection rates for faults condition %
算法统计
参数
故障4故障8故障13故障18
FARFDRFARFDRFARFDRFARFDR
PCA$ {T}^{2} $2.5049.631.2597.371.8790.033.1287.52
PCA$ \mathrm{S}\mathrm{P}\mathrm{E} $13.1310016.8797.7510.0492.6412.5289.89
W-PL$ \mathrm{l}\mathrm{o}\mathrm{f} $2.7699.253.4597.25094.286.2189.27
M-PLBIC8.131007.5097.885.0095.215.6289.14
M-WPBIC0.7099.881.9299.111.9295.933.2091.61