单边螺栓连接T形件-钢管节点高温下及高温后受拉性能
尤洋,王培军,孙乐乐,叶继红,姜健

Tensile behavior of one-side bolted T-stub to tube connection at fire and post-fire circumstances
Yang YOU,Pei-jun WANG,Le-le SUN,Ji-hong YE,Jian JIANG
表 7 所提公式的计算结果与试验结果比较
Tab.7 Comparison of calculated result given by proposed equations and test results
试件 θ/℃ 试验结果 计算结果 (FE·FY−1)/%
FY/kN 破坏
模式
FE/kN 破坏
模式
S1 20 28.1 1 27.2 1 96.8
S1 500 17.2 1 16.9 1 98.3
S1 700 5.5 1 5.4 1 98.2
S2 20 118.8 2 125.4 2 105.6
S2 500 68.5 2 72.7 2 106.1
S2 700 17.5 2 18.9 2 108.0
S3 20 47.7 3 42.8 3 89.7
S3 500 23.1 3 25.1 3 108.7
S3 700 8.0 3 8.3 3 103.8
S4 20 74.1 4 74.2 4 100.1
S4 500 43.2 4 41.2 4 95.4
S4 700 9.3 4 10.0 4 107.5