单边螺栓连接T形件-钢管节点高温下及高温后受拉性能
|
尤洋,王培军,孙乐乐,叶继红,姜健
|
Tensile behavior of one-side bolted T-stub to tube connection at fire and post-fire circumstances
|
Yang YOU,Pei-jun WANG,Le-le SUN,Ji-hong YE,Jian JIANG
|
|
表 3 试件的恒温加载高温试验结果 |
Tab.3 Steady-state test result of specimens |
|
试件 | θ/℃ | FY/kN | FU/kN | 破坏模式 | S1 | 500 | 17.2 | 27.2 | 钢管屈服破坏 | S1 | 700 | 5.5 | 7.5 | 钢管屈服破坏 | S2 | 500 | 68.5 | 113.2 | 端板屈服伴随螺栓破坏 | S2 | 700 | 17.5 | 25.9 | 端板屈服伴随螺栓破坏 | S3 | 500 | 23.1 | 38.7 | 端板屈服破坏 | S3 | 700 | 8.0 | 14.6 | 端板屈服破坏 | S4 | 500 | 43.2 | 53.7 | 螺栓拉断 | S4 | 700 | 9.3 | 11.3 | 螺栓拉断 | S5 | 500 | 18.7 | 36.1 | 钢管屈服破坏 | S5 | 700 | 5.7 | 8.7 | 钢管屈服破坏 | S6 | 500 | 68.6 | 110.6 | 端板屈服伴随螺栓破坏 | S6 | 700 | 18.5 | 27.2 | 端板屈服伴随螺栓破坏 |
|
|
|