不同连接方式叠合板-现浇梁滞回性能试验研究
|
郑嘉润,张明山,李本悦,徐铨彪,龚顺风
|
Experimental study on hysteretic behavior of composite slab and cast-in-situ beam with different connection modes
|
Jia-run ZHENG,Ming-shan ZHANG,Ben-yue LI,Quan-biao XU,Shun-feng GONG
|
|
表 3 试件特征点处的弯矩和位移角 |
Tab.3 Moment and drift ratio at characteristic points of specimens |
|
试件 规格 | 加载 方向 | My/ (kN·m) | ϕy | Mmax/ (kN·m) | ϕmax | ϕu | μ | A1 | (+) | +16.8 | +0.010 | +19.6 | +0.030 | — | — | A1 | (−) | −12.0 | −0.013 | −14.0 | −0.018 | −0.031 | 2.40 | A2 | (+) | +17.1 | +0.008 | +20.1 | +0.027 | — | — | A2 | (−) | −11.6 | −0.010 | −13.8 | −0.020 | −0.029 | 2.78 | A3 | (+) | +18.2 | +0.011 | +20.6 | +0.024 | — | — | A3 | (−) | −13.1 | −0.007 | −14.8 | −0.018 | −0.033 | 4.70 | B1 | (+) | +16.9 | +0.007 | +20.3 | +0.015 | — | — | B1 | (−) | −12.8 | −0.009 | −15.0 | −0.015 | −0.019 | 2.17 | B2 | (+) | +14.2 | +0.006 | +19.8 | +0.020 | — | — | B2 | (−) | −12.3 | −0.007 | −14.7 | −0.020 | −0.040 | 5.63 | B3 | (+) | +19.0 | +0.009 | +22.1 | +0.020 | — | — | B3 | (−) | −12.7 | −0.007 | −15.2 | −0.020 | −0.044 | 6.29 | C1 | (+) | +18.0 | +0.009 | +21.0 | +0.030 | — | — | C1 | (−) | −11.1 | −0.007 | −13.5 | −0.015 | −0.028 | 3.95 | C2 | (+) | +18.8 | +0.009 | +21.2 | +0.020 | — | — | C2 | (−) | −10.5 | −0.007 | −12.7 | −0.020 | −0.029 | 4.12 | C3 | (+) | +20.0 | +0.010 | +21.3 | +0.015 | — | — | C3 | (−) | −11.7 | −0.007 | −13.7 | −0.010 | −0.063 | 8.70 | D1 | (+) | +27.4 | +0.012 | +31.7 | +0.040 | — | — | D1 | (−) | −8.6 | −0.014 | −9.5 | −0.020 | — | — | E1 | (+) | +17.1 | +0.008 | +20.3 | +0.020 | +0.054 | 6.81 | E1 | (−) | −14.5 | −0.010 | −16.5 | −0.025 | −0.051 | 4.82 |
|
|
|