表 8 多工况模式匹配优化结果-2#炉 |
Tab.8 Optimization results of pattern matching under multiple working conditions-2#boiler |
|
工况 | qmsteam/(t·h−1) | Sxm/% | Sxo/% | EdeBoiler/% | ftotalGM/Hz | ftotalSF/Hz | ftotalYF/Hz | 工况1(原始) | 113.57 | — | — | — | 40.69 | 48.87 | 41.42 | 工况1(优化后) | 119.95 | 97.57 | 97.57 | 0.65 | 41.42 | 50.29 | 40.61 | 工况2(原始) | 133.93 | — | — | — | 46.12 | 52.96 | 45.06 | 工况2(优化后) | 131.23 | 98.88 | 98.73 | 1.24 | 46.26 | 51.77 | 44.25 | 工况3(原始) | 144.49 | — | — | — | 50.14 | 53.93 | 47.06 | 工况3(优化后) | 141.24 | 98.67 | 99.86 | 0.04 | 50.02 | 53.92 | 47.04 | 工况4(原始) | 158.02 | — | — | — | 55.72 | 55.68 | 52.96 | 工况4(优化后) | 157.98 | 99.68 | 99.80 | 0.05 | 55.72 | 55.68 | 52.96 | 工况5(原始) | 181.26 | — | — | — | 62.85 | 61.92 | 62.81 | 工况5(优化后) | 189.13 | 97.61 | 99.13 | 0.77 | 64.41 | 62.57 | 62.02 | 工况6(原始) | 197.58 | — | — | — | 70.14 | 66.28 | 65.64 | 工况6(优化后) | 198.51 | 99.60 | 99.91 | 0.05 | 70.03 | 66.30 | 65.65 |
|
|
|