基于代理模型模式匹配的锅炉实时操作优化
钟崴,林雪茹,林小杰,周懿

Optimization of boiler real-time operation based on pattern-matching of agent model
Wei ZHONG,Xue-ru LIN,Xiao-jie LIN,Yi ZHOU
表 5 多工况模式匹配的优化结果-1#炉
Tab.5 Optimization results of pattern matching under multiple working conditions-1# boiler
工况 qmsteam/(t·h−1) Sxm/% Sxo/% EdeBoiler/% ftotalGM/Hz ftotalSF/Hz ftotalYF/Hz
工况1(原始) 191.16 79.30 58.44 58.23
工况1(优化后) 199.06 98.28 97.27 1.92 78.22 58.51 59.45
工况1(仅考虑工况相似) 197.73 98.83 96.19 2.10 79.74 57.66 58.24
工况1(仅考虑工况相似与操作相似) 189.96 99.84 99.89 0.06 79.19 58.42 58.24
工况2(原始) 170.66 71.39 56.01 52.98
工况2(优化后) 162.98 98.47 95.14 0.41 67.23 54.01 51.96
工况3(原始) 140.58 55.29 49.97 42.28
工况3(优化后) 140.25 99.44 95.13 0.64 55.29 49.97 42.28
工况4(原始) 123.29 52.55 46.14 39.46
工况4(优化后) 120.31 97.00 93.76 0.22 52.15 45.73 39.68
工况5(原始) 103.55 47.47 45.77 39.30
工况5(优化后) 111.00 98.00 95.82 0.93 46.91 44.95 38.67
工况6(原始) 192.68 78.25 59.84 58.24
工况6(优化后) 201.55 97.40 94.46 0.73 74.23 61.74 63.34
工况7(原始) 194.62 78.06 61.89 62.31
工况7(优化后) 199.60 97.99 96.92 0.60 74.13 61.76 63.33
工况8(原始) 195.16 83.82 61.10 61.51
工况8(优化后) 201.70 97.51 92.63 0.76 74.20 61.74 63.34
工况9(原始) 201.01 82.22 60.30 61.51
工况9(优化后) 199.60 99.09 93.32 0.66 74.13 61.76 63.33