基于动态内并行潜结构投影的故障检测方法
|
孔祥玉,陈雅琳,罗家宇,杨治艳
|
Fault detection method based on dynamic inner concurrent projection to latent structure
|
Xiang-yu KONG,Ya-lin CHEN,Jia-yu LUO,Zhi-yan YANG
|
|
表 3 质量无关故障的误报率 |
Tab.3 False alarm rates of quality-unrelated fault % |
|
故障 编号 | DTPLS | | OMDC-PLS | | OM-DiCPLS | ${S_{\rm{D}}}$ | ${S_{{\rm{WD}}} }$ | ${S_{{\rm{WG}}} }$ | ${S_{{\rm{DT}}} }$ | ${S_{{\rm{CVS}}} }$ | ${S_{{\rm{IPS}}} }$ | ${S_{{\rm{IRS}}} }$ | ${S_{{\rm{OPS}}} }$ | ${S_{{\rm{ORS}}} }$ | ${S_{{\rm{CVS}}} }$ | ${S_{{\rm{IPS}}} }$ | ${S_{{\rm{IRS}}} }$ | ${S_{{\rm{OPS}}} }$ | ${S_{{\rm{ORS}}} }$ | 3 | 13.84 | 11.65 | 6.13 | 5.75 | | 14.88 | 5.00 | 01.74 | 10.20 | 00.50 | | 07.42 | 03.89 | 98.87 | 50.69 | 45.66 | 4 | 24.22 | 14.04 | 95.63 | 99.88 | 14.75 | 52.00 | 100.0 | 09.00 | 01.25 | 07.04 | 25.91 | 100.0 | 58.87 | 50.44 | 9 | 14.09 | 10.78 | 07.88 | 7.63 | 15.88 | 6.38 | 02.17 | 06.38 | 00.50 | 08.68 | 03.77 | 99.50 | 49.56 | 44.40 | 11 | 29.36 | 31.33 | 69.13 | 71.13 | 27.50 | 64.13 | 89.35 | 07.38 | 00.75 | 11.70 | 47.92 | 100.0 | 62.52 | 65.53 | 14 | 99.62 | 100.0 | 100.0 | 91.13 | 4.75 | 99.88 | 100.0 | 06.50 | 01.00 | 03.27 | 100.0 | 100.0 | 41.51 | 38.99 | 15 | 14.34 | 10.03 | 05.88 | 8.25 | 11.25 | 9.88 | 01.74 | 11.00 | 00.75 | 08.30 | 03.90 | 97.99 | 46.79 | 40.63 |
|
|
|