基于热裂纹演化的玻化微珠保温混凝土渗透性能分析
|
李明厚,SELYUTINA Nina ,SMIRNOV Ivan ,张祥,李贝贝,刘元珍,张玉
|
Permeability analysis of glazed hollow beads insulation concrete based on thermal crack evolution
|
Ming-hou LI,Nina SELYUTINA,Ivan SMIRNOV,Xiang ZHANG,Bei-bei LI,Yuan-zhen LIU,Yu ZHANG
|
|
表 7 电通量的计算值与预测值对比结果 |
Tab.7 Comparison between calculated value and predicted value of electric flux |
|
$ \theta $/℃ | NC | | SFC | | GIC | ${Q_{\rm{e}}}$/C | $ {Q_{\text{p}}} $/C | ${\varDelta }$/% | ${Q_{\rm{e}}}$/C | $ {Q_{\text{p}}} $/C | ${\varDelta }$/% | ${Q_{\rm{e}}}$/C | $ {Q_{\text{p}}} $/C | ${\varDelta}$/% | 20 | 600 | 1092 | 82.18 | | 224 | 285 | 26.81 | | 97 | 105 | 7.28 | 100 | 1867 | 1092 | 41.49 | 346 | 393 | 13.52 | 104 | 144 | 38.89 | 200 | 3506 | 3425 | 2.31 | 2148 | 1812 | 15.62 | 1221 | 1029 | 15.68 | 300 | 4372 | 4487 | 2.62 | 3078 | 3220 | 4.61 | 2773 | 2905 | 4.75 | 400 | 4843 | 4903 | 1.24 | 3957 | 4069 | 2.82 | 3579 | 3729 | 4.19 | 500 | 5055 | 5034 | 0.42 | 4410 | 4337 | 1.66 | 4103 | 3978 | 3.05 |
|
|
|