摘要:

为研究土壤分层特性对埋地换热器传热的影响,将不同土层的埋管换热器简化为分层圆柱面热源,同时根据叠加原理,构建考虑土壤分层的埋管换热器解析传热模型,并用Ansys有限元模型验证传热模型的合理性.分层传热模型与均质传热模型的计算结果对比表明:采用土壤分层传热模型计算得到的钻孔壁温升具有明显的分层特性,分层土壤导热系数和热扩散系数相对均质参数越大,计算得到的钻孔壁温升越小;采用分层传热模型计算得到的土壤稳态温升与均质模型计算结果存在较大差别;在考虑土壤分层时,地下埋管中循环液的出口温度与均质模型计算结果存在差异.

Abstract:

In order to study the impact of soil stratification on the performances of underground heat exchanger, the heat exchanger in different soil layers has been simplified as the cylindrical surface heat source in each layer. An analytical heat transfer model considering soil stratification has been established based on the principle of superposition, and validated by FEM model of commercial software Ansys. The results of the present proposed model and the homogeneous heat transfer model were compared. It indicates that the borehole wall temperature rise calculated by the proposed model has a significant character of stratification, which decreases with the increasing soil thermal conductivity and thermal diffusivity of soil layer; the soil temperature rise calculated by the proposed stratified heat exchanger model is quite different from that calculated by the homogeneous model; once the soil stratification is taken into consideration, the temperature of circulating fluid temperature at the tube outlet is also different from that calculated by the homogeneous heat transfer model.

出版日期: 2013-08-01
:  TU 111  
基金资助:

浙江省重点科技创新团队计划资助项目(2010R50037).

通讯作者: 邵卫云,女,副教授.     E-mail: shaowy@zju.edu.cn
作者简介: 王子阳(1988—),男,硕士生,主要从事市政工程、建筑节能方向的研究.E-mail:wzyzju@163.com
服务  
把本文推荐给朋友
加入引用管理器
E-mail Alert
RSS
作者相关文章  

引用本文:

王子阳, 邵卫云, 张仪萍. 考虑土壤分层的地源热泵圆柱面热源模型[J]. J4, 2013, 47(8): 1338-1345.

WANG Zi-yang, SHAO Wei-yun, ZHANG Yi-ping. Cylindrical surface model of ground source heat pump considering soil stratification. J4, 2013, 47(8): 1338-1345.

链接本文:

http://www.zjujournals.com/eng/CN/10.3785/j.issn.1008-973X.2013.08.003        http://www.zjujournals.com/eng/CN/Y2013/V47/I8/1338

[1] SPITLER J D. Editorial: ground-source heat pump system research-past, present, and future [J]. HVAC&R Research, 2005, 11(2): 165-167.

[2] DEERMAN J D, KAVANAUGH S P. Simulation of vertical U-tube ground coupled heat pump systems using the cylindrical heat source solution [J]. ASHRAE Transactions, 1991, 97(1): 287-295.

[3] CHIASSON. Advances in modeling of ground source heat pump systems [D]. Oklahoma: Oklahoma State University, 1999.

[4] DIAO Nai-ren, ZENG He-yi, FANG Zhao-hong. Improvement in modeling of heat transfer in vertical ground heat exchangers [J]. HVAC & R Research, 2004, 10(4): 45970.

[5] YAVUZTURK C, SPITLER J D, REES S J. A transient two-dimensional nite volume model for the simulation of vertical U-tube ground heat exchangers [J]. ASHRAE Transactions, 1999, 105(A): 46574.

[6] BANDOS T V, MONTERO , FERNNDEZ E, et al. Finite line-source model for borehole heat exchangers: effect of vertical temperature variations [J]. Geothermics, 2009, 38(2): 263-270.

[7] 王泽生,颜爱斌,郭进京. 地下层状结构土体中埋管换热器的传热分析[J]. 太阳能学报,2009, 30(2): 188-192.

WANG Ze-sheng,YAN Ai-bin, GUO Jin-jing. Heat transfer analysis of underground heat exchangers in multi-soil beds [J]. Acta energiae solaris sinica, 2009, 30(2): 188-192.

[8] WOOD C J, LIU H. Use of energy piles in a residential building, and effects on ground temperature and heat pump efficiency [J]. Geotechnique, 2009, 59 (3): 287-290.

[9] BRANDL H. Energy foundations and other thermo-active ground structures [J]. Geotechnique, 2006, 56 (2): 81-122.

[10] 战国会,俞亚南.地源热泵有限长圆柱面和圆柱体热源模型研究[J].浙江大学学报:工学版,2011, 45(6): 1104-1107.

ZHAN Guo-hui, YU Ya-nan. Study on finite long cylindrical surface and cylinder source model of ground source heat pump [J].Journal of Zhejiang University: Engineering Science,2011, 45(6): 1104-1107.

[11] 李芃,仇中柱,于立强. U型垂直埋管式土壤源热泵埋管周围温度场的理论研究[J]. 暖通空调. 2002, 32(1): 17-20.

LI Fan, QIU Zhong-zhu,YU Li-qiang. Research of the temperature field around the U-tubes of a ground-coupled heat pump[J]. Heating Ventilating & Air Conditioning, 2002, 32(1): 17-20.

[12] 王茂盛. 地热换热器循环液温度设定对地源热泵系统影响的分析与研究[D]. 济南:山东建筑大学, 2010.

WANG Mao-sheng. The impact and study to ground source heat pump of inlet and outlet temperature design of the circulating fluid in the ground heat exchanger [D]. Jinan: Shandong Jianzhu University, 2010.

[13] 曾和义,刁乃仁,方肇洪.竖直埋管地热换热器钻孔内的传热分析[J]. 太阳能学报. 2004, 25(3): 399-405.

ZENG He-yi,DIAO Nai-ren,FANG Zhao-hong. Analysis of the heat transfer inside a borehole of vertical ground heat exchangers [J]. Acta energiae solaris sinica, 2004, 25(3): 399-405.

[14] 刁乃仁,曾和义,方肇洪.竖直U型管地热换热器的准三维传热模型[J].热能动力工程. 2003, 18(4): 387-390.

DIAO Nai-ren, ZENG He-yi, FANG Zhao-hong. A quasi three-dimensional heat transfer model for vertical U-tube geothermal heat exchangers [J]. Journal of Engineering for Thermal Energy & Power, 2003, 18(4): 387-390.

[1] 王子阳, 张仪萍, 战国会, 俞亚南. 有渗流时埋管换热器传热模型[J]. J4, 2012, 46(8): 1450-1456.
[2] 战国会, 张仪萍, 徐坚, 俞亚南. 地源热泵群孔长期换热有限长体热源模型[J]. J4, 2011, 45(8): 1411-1415.
[3] 战国会, 俞亚南. 地源热泵有限长圆柱面和圆柱体热源模型[J]. J4, 2011, 45(6): 1104-1107.
[4] 俞亚南, 徐坚, 冯建江. 粉性土导热系数的室内实验研究[J]. J4, 2010, 44(1): 180-183.