Please wait a minute...
J4  2010, Vol. 44 Issue (8): 1535-1539    DOI: 10.3785/j.issn.1008-973X.2010.08.018
机械工程     
异型腔流量传感器
雷华1,蒋冠雷2,蒋宗延2,吴思雨2,鲁阳1
1. 浙江大学 航空航天学院,浙江 杭州 310027; 2. 浙江大学 机械工程学系,浙江 杭州 310027
Profiled chamber flow sensor
LEI Hua1, JIANG Guan-lei2, JIANG Zong-yan2, WU Si-yu2, LU Yang1
1. School of Aeronautics and Astronautics, Zhejiang University, Hangzhou 310027, China;
2. Department of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
 全文: PDF  HTML
摘要:

为了克服现有容积式流量传感器构造复杂、精度稳定性差等缺点,设计一种新型流量传感器异型腔流量传感器(PCF).PCF的关键部件是一个带有异型面内腔的壳体和一个装有十字交叉组合滑板的转子.异型面内腔由半径不等的2个1/4圆弧面和2个1/4非圆弧面组合构成,异型面内腔与转子配合,控制十字交叉组合滑板的运动.组合滑板内置弹性元件,有一定的伸缩性,可以自动补偿滑板端部的磨损,使测量精度保持稳定,并且使转子具有防止被流体所含固体颗粒卡阻的能力.PCF有单向工作和双向工作2种基本类型,两者的内腔结构略有差别.PCF结构简单,以其结构形式为基础,还可以设计具备流量计量功能的泵及原动机.

Abstract:

A new type of flow sensor called profiled chamber flow sensor (PCF) was designed to overcome the default of existed volumetric flow sensor, including their complexity in structures and instability in measurement accuracy. The vital parts of PCF was a shell with characterized inner profiled chamber and a rotor with a pair of cross combined sliding plates. The inner profiled chamber had two quarter circular surfaces with different radius and two quarter noncircular surfaces, matching with the rotor and control the moves of cross combined sliding plates. By embedded elastic units, the cross sliding plates can compensate its end wear loss and avoid block caused by small particles in fluid, thus the persistence of measurement precision and a better reliability will achieve. PCF can be designed to work unidirectionally and bidirectionally through a little adjustment on inner profiled chamber. The structure of PCF is very simple, based on which pumps and prime movers with metering function of flow rate can be developed.

出版日期: 2010-09-21
:  TH 71  
基金资助:

国家自然科学基金资助项目(10572127);浙江省科技计划资助项目(2009C31076)

作者简介: 雷华(1974-),男,四川中江人,讲师,从事力学实验、复合材料制备及表征的研究. E-mail: hualei@zju.edu.cn
服务  
把本文推荐给朋友
加入引用管理器
E-mail Alert
RSS
作者相关文章  

引用本文:

雷华, 蒋冠雷, 蒋宗延, 吴思雨, 鲁阳. 异型腔流量传感器[J]. J4, 2010, 44(8): 1535-1539.

LEI Hua, JIANG Guan-Lei, JIANG Zong-Yan, TUN Sai-Yu, LU Yang. Profiled chamber flow sensor. J4, 2010, 44(8): 1535-1539.

链接本文:

http://www.zjujournals.com/eng/CN/10.3785/j.issn.1008-973X.2010.08.018        http://www.zjujournals.com/eng/CN/Y2010/V44/I8/1535

[1] 周庆,HAAG R,王磊. 实用流量仪表的原理及其应用[M]. 2版. 北京:国防工业出版社,2008: 2537.
[2] 萧汉卿. 容积式流量计[M]. 北京:中国计量出版社,1997: 215.
[3] JESSE Y. Traditional flowmeters hold their own [J]. Control Solutions, 2003, 10(1):3337.
[4] JESSE Y. Something to be said for traditionLegacy flow measurement systems live on [J]. Flow Control, 2008, 14(11): 3032.
[5] JESSE Y. A new perspective on traditional technology flowmeters [J]. Flow Control, 2008, 14(11): 3135.
[6] 孙志强,张宏建,黄咏梅,等. 管壁差压式涡街流量计测量影响因素分析[J]. 浙江大学学报: 工学版,2006,40(12):21032106.
SUN Zhiqiang, ZHANG Hongjian, HUANG Yongmei, et al. Impact analysis of vortex flowmeter measured with ductwall differential pressure method [J]. Journal of Zhejiang University: Engineering Science, 2006, 40(12): 21032106.

No related articles found!