Please wait a minute...
Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology)  2010, Vol. 11 Issue (12): 931-936    DOI: 10.1631/jzus.B1000058
Medical Electronics     
Electromagnetic effects on the biological tissue surrounding a transcutaneous transformer for an artificial anal sphincter system
Peng Zan, Bang-hua Yang, Yong Shao, Guo-zheng Yan, Hua Liu
Shanghai Key Laboratory of Power Station Automation Technology, College of Mechatronics Engineering and Automation, Shanghai University, Shanghai 200072, China, School of Electronics, Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
Download:     PDF (0 KB)     
Export: BibTeX | EndNote (RIS)      

Abstract  This paper reports on the electromagnetic effects on the biological tissue surrounding a transcutaneous transformer for an artificial anal sphincter. The coupling coils and human tissues, including the skin, fat, muscle, liver, and blood, were considered. Specific absorption rate (SAR) and current density were analyzed by a finite-length solenoid model. First, SAR and current density as a function of frequency (10–107 Hz) for an emission current of 1.5 A were calculated under different tissue thickness. Then relations between SAR, current density, and five types of tissues under each frequency were deduced. As a result, both the SAR and current density were below the basic restrictions of the International Commission on Non-Ionizing Radiation Protection (ICNIRP). The results show that the analysis of these data is very important for developing the artificial anal sphincter system.

Key wordsArtificial anal sphincter      Transcutaneous energy transmission      Current density      Specific absorption rate     
Received: 22 February 2010      Published: 09 December 2010
CLC:  R318.6  
Cite this article:

Peng Zan, Bang-hua Yang, Yong Shao, Guo-zheng Yan, Hua Liu. Electromagnetic effects on the biological tissue surrounding a transcutaneous transformer for an artificial anal sphincter system. Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology), 2010, 11(12): 931-936.

URL:

http://www.zjujournals.com/xueshu/zjus-b/10.1631/jzus.B1000058     OR     http://www.zjujournals.com/xueshu/zjus-b/Y2010/V11/I12/931

[1] Ming-hui Wang, Ying Zhou, Shuang Zhao, Yun Luo. Challenges faced in the clinical application of artificial anal sphincters[J]. Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology), 2015, 16(9): 733-742.
[2] Peng ZAN, Guo-zheng YAN, Hua LIU. Modeling of human colonic blood flow for a novel artificial anal sphincter system[J]. Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology), 2008, 9(9): 734-738.
[3] GAO Nuo, ZHU Shan-an, HE Bin. Use of 3-D magnetic resonance electrical impedance tomography in detecting human cerebral stroke: a simulation study*[J]. Journal of Zhejiang University-SCIENCE B (Biomedicine & Biotechnology), 2005, 6( 5): 23-.