Please wait a minute...
Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering)  2014, Vol. 15 Issue (7): 508-516    DOI: 10.1631/jzus.A1400052
Civil and Mechanical Engineering     
Performance of a precooled 4 K Stirling type high frequency pulse tube cryocooler with Gd2O2S
Zhuo-pei Li, Yan-long Jiang, Zhi-hua Gan, Li-min Qiu, Jie Chen
Man-machine Environment Engineering, College of Aerospace Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China; Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027, China; Nanjing Cooltech Cryogenic Technology Co., Ltd., Nanjing 211113, China
Download:     PDF (0 KB)     
Export: BibTeX | EndNote (RIS)      

Abstract  The efficiency of 4 K Stirling type pulse tube cryocoolers (SPTCs) is rather low due to significant regenerator losses associated with the unique properties of helium around 4 K and the high operating frequencies. In this paper, regenerator performance at liquid helium temperature regions under high frequencies is investigated based on a single-stage SPTC precooled by a two-stage Gifford-McMahon type pulse tube cryocooler (GMPTC). The 4 K SPTC used a 10 K cold inertance tube as phase shifters for better phase relationship between pressure and mass flow. The effect of the operating parameters, including frequency and average pressure on the performance of the 4 K SPTC, was investigated and the first and second precooling powers provided by the GMPTC were obtained. To reduce the regenerator heat transfer losses, a multi-layer regenerator matrix, including Gd2O2S (GOS) and HoCu2, was used instead of a single-layer HoCu2 around 4 K. A theoretical and experimental comparison between the two types of regenerator materials was made and the precooling requirements for a regenerator operating at high frequencies to reach liquid helium temperatures were given, which provided guidance for the design of a three-stage SPTC.

Key wordsStirling type pulse tube cryocooler (SPTC)      4 K      Regenerator material      Regenerator loss      High frequency      Precool      Cold inertance tube     
Received: 18 February 2014      Published: 08 July 2014
CLC:  TK123  
Cite this article:

Zhuo-pei Li, Yan-long Jiang, Zhi-hua Gan, Li-min Qiu, Jie Chen. Performance of a precooled 4 K Stirling type high frequency pulse tube cryocooler with Gd2O2S. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2014, 15(7): 508-516.

URL:

http://www.zjujournals.com/xueshu/zjus-a/10.1631/jzus.A1400052     OR     http://www.zjujournals.com/xueshu/zjus-a/Y2014/V15/I7/508

[1] Zhi-hua GAN, Zhuo-pei LI, Jie CHEN, Li DAI, Li-min QIU. Design and preliminary experimental investigation of a 4 K Stirling-type pulse tube cryocooler with precooling[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2009, 10(9): 1277-1284.
[2] Zhi-hua GAN, Guo-jun LIU, Ying-zhe WU, Qiang CAO, Li-min QIU, Guo-bang CHEN, J.M. PFOTENHAUER. Study on a 5.0 W/80 K single stage Stirling type pulse tube cryocooler[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2008, 9(9): 1277-1282.
[3] Zheng-shi WANG, Hui-ming CHEN. Zero-voltage switching converter absorbing parasitic parameters for super high frequency induction heating[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2008, 9(4): 564-571.