Please wait a minute...
Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering)  2004, Vol. 5 Issue (3): 317-325    DOI: 10.1631/jzus.2004.0317
Civil Engineering     
Semi-active control of a cable-stayed bridge under multiple-support excitations
DAI Ze-bing, HUANG Jin-zhi, WANG Hong-xia
School of Civil Engineering and Mechanics, Shanghai Jiaotong University, Shanghai 200240, China
Download:     PDF (0 KB)     
Export: BibTeX | EndNote (RIS)      

Abstract  This paper presents a semi-active strategy for seismic protection of a benchmark cable-stayed bridge with consideration of multiple-support excitations. In this control strategy, Magnetorheological (MR) dampers are proposed as control devices, a LQG-clipped-optimal control algorithm is employed. An active control strategy, shown in previous researches to perform well at controlling the benchmark bridge when uniform earthquake motion was assumed, is also used in this study to control this benchmark bridge with consideration of multiple-support excitations. The performance of active control system is compared to that of the presented semi-active control strategy. Because the MR fluid damper is a controllable energy-dissipation device that cannot add mechanical energy to the structural system, the proposed control strategy is fail-safe in that bounded-input, bounded-output stability of the controlled structure is guaranteed. The numerical results demonstrated that the performance of the presented control design is nearly the same as that of the active control system; and that the MR dampers can effectively be used to control seismically excited cable-stayed bridges with multiple-support excitations.

Key wordsCable-stayed bridge      Multiple-support excitation      MR damping      Semi-active control     
Received: 04 March 2003     
CLC:  U448.27  
  TU311.3  
Cite this article:

DAI Ze-bing, HUANG Jin-zhi, WANG Hong-xia. Semi-active control of a cable-stayed bridge under multiple-support excitations. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2004, 5(3): 317-325.

URL:

http://www.zjujournals.com/xueshu/zjus-a/10.1631/jzus.2004.0317     OR     http://www.zjujournals.com/xueshu/zjus-a/Y2004/V5/I3/317

[1] Rui Zhou, Zhou-hong Zong, Xue-yang Huang, Zhang-hua Xia. Seismic response study on a multi-span cable-stayed bridge scale model under multi-support excitations. Part II: numerical analysis[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2014, 15(6): 405-418.
[2] Zhou-hong Zong, Rui Zhou, Xue-yang Huang, Zhang-hua Xia. Seismic response study on a multi-span cable-stayed bridge scale model under multi-support excitations. Part I: shaking table tests[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2014, 15(5): 351-363.
[3] Hao Wang, Tian-you Tao, Huai-yu Cheng, Ai-qun Li. A simulation study on the optimal control of buffeting displacement for the Sutong Bridge with multiple tuned mass dampers[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2014, 15(10): 798-812.
[4] Jian-guo Cai, Yi-xiang Xu, Li-ping Zhuang, Jian Feng, Jin Zhang. Comparison of various procedures for progressive collapse analysis of cable-stayed bridges[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2012, 13(5): 323-334.
[5] Hao Wang, Zhou-hong Zong, Ai-qun Li, Teng Tong, Jie Niu, Wen-ping Deng. Digital simulation of 3D turbulence wind field of Sutong Bridge based on measured wind spectra[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2012, 13(2): 91-104.
[6] He Zhang, Xu Xie. Dynamic responses of cable-stayed bridges to vehicular loading including the effects of the local vibration of cables[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2011, 12(8): 593-604.
[7] Wu Hua-Cheng, Xiang Yi-Qiang, Wang Jin-Feng. Condition assessment of long span cable-stayed bridge[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2006, 7(Supplement 2): 297-308.
[8] WU Gao-feng, XU Hong. Theoretical and experimental study on shear lag effect of partially cable-stayed bridge[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2005, 6(8): 875-877.
[9] ZHANG Xin-jun, SUN Bing-nan, XIANG Hai-fan. Aerodynamic stability of cable-stayed bridges under erection[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2005, 6( 3): 4-.
[10] SUN Bing-nan, WANG Zhi-gang, KO, J.M., NI, Y.Q.. Parametrically excited oscillation of stay cable and its control in cable-stayed bridges[J]. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 2003, 4(1): 13-20.