双向干线协调控制的改进数解算法
曾佳棋,王殿海

Improved numerical method for two-way arterial signal coordinate control
Jia-qi ZENG,Dian-hai WANG
表 10 算例4各理想信号间距与匹配程度指标对应关系
Tab.10 Relationship of ideal signal spacing and matching degree indicators for example 4
a /m b /m ba−1 /% dmax /m B/%
  注:“▲”为各方法最优解标记符号.
460 120 26.1 170 20.9
470 150 31.9 160 22.7
480 180 37.5 150 23.3
490 210 42.9 140▲ 23.9
500 220 44.0▲ 140▲ 24.5
510 200 39.2 155 25.1
520 170 32.7 175 25.6
530 140 26.4 195 24.8
540 150 27.8 195 24.2
550 190 34.5 180 24.8
560 210 37.5 175 27.5
570 220 38.6 175 27.9▲
580 190 32.8 195 26.5
590 160 27.1 215 26.2
600 150 25.0 225 25.0
610 140 23.0 235 22.3
620 130 21.0 245 20.5
630 160 25.4 235 22.7
640 190 29.7 225 24.4
650 220 33.8 215 24.0
660 250▲ 37.9 205 23.7