土木工程、工程力学 |
|
|
|
|
电极反转对电渗加固效果的试验研究 |
陈卓1,2,周建1,温晓贵1,陶燕丽1 |
1.浙江大学 软土与环境工程教育部重点实验室,浙江 杭州 310058;
2. 天津市软土特性与工程环境重点实验室,天津 300384 |
|
Experimental research on effect of polarity reversal to electro-osmotic |
CHEN Zhuo 1,2 , ZHOU Jian1, WEN Xiao-gui1,TAO Yan-li1 |
1. Key Laboratory of Soft Soil and Geoenvironmental Engineering, Zhejiang University, Hangzhou 310058, China;
2. Tianjin Key Laboratory of Soft Soil Characteristics and Engineering Environment, Tianjin 300384, China |
引用本文:
陈卓,周建,温晓贵,陶燕丽. 电极反转对电渗加固效果的试验研究[J]. J4, 2013, 47(9): 1579-1584.
CHEN Zhuo , ZHOU Jian, WEN Xiao-gui,TAO Yan-li. Experimental research on effect of polarity reversal to electro-osmotic. J4, 2013, 47(9): 1579-1584.
链接本文:
http://www.zjujournals.com/eng/CN/10.3785/j.issn.1008-973X.2013.09.010
或
http://www.zjujournals.com/eng/CN/Y2013/V47/I9/1579
|
[1] 李 瑛,龚晓南. 软黏土地基电渗加固的设计方法研究[J].岩土工程学报,2011,33(6):955-959.
LI Ying, GONG Xiao-nan. Design method of electro-osmotic reinforcement for soft clay foundations[J]. Chinese Journal of Geotechnical Engineering, 2011,33(6):955-959.
[2] 李 瑛. 软黏土地基电渗固结试验和理论研究[D]. 杭州:浙江大学,2011:8142.
LI Ying. Experimental and theoretic study on electro-osmotic consolidation of soft clay foundation [D]. Hangzhou: Zhejiang University, 2011: 8142.
[3] WAN T Y, MITCHELL J K. Electro-Osmotic Consolidation of Soils [J]. Journal of Geotechnical Geotechnical Division, ASCE, 1976, 102(5): 473-491.
[4] LO K Y, HO K S. The effects of electroosmotic field treatment on the soil properties of a soft sensitive clay[J]. Canadian Geotechnical Journal, 1991, 28(6): 763-770.
[5] SHANG J Q. Electrokinetic dewatering of clay slurries as engineered soil covers[J].Canadian Geotechnical Journal,1997, 34:78-86.
[6] 王协群, 邹维列. 电渗排水法加固湖相软黏土的试验研究[J]. 武汉理工大学学报, 2007, 29(2): 95-99.
WANG Xie-qun, ZOU Wei-lie. Experimental research on electro-osmotic consolidation of lacustrine clay[J].Journal of Wuhan University of Technology, 2007, 29(2): 95-99.
[7] OU Chang-yu, CHIEN Shao-chi, CHANG Hsuan-hsiang. Soil improvement using electroosmosis with the injection of chemical solutions: field tests[J].Canadian Geotechnical Journal, 2009, 46:727-733.
[8] MICIC S, SHANG J Q, LO K Y. Electrokinetic strengthening of marine clay adjacent to offshore foundations[C]∥Proceedings of the Eleventh international Offshore and Polar Engineering Conference. Stavanger , Norway: [s. n.], 2001:694-701.
[9] YOSHIDA H, KITAJYAO K, NAKAYAMA M. Electroosmotic dewatering under A.C. electric field with periodic reversals of electrode polarity[J]. Drying Technology, 1999, 17(3): 539-554.
[10] 李 瑛, 龚晓南, 张雪婵. 电压对一维电渗排水影响的试验研究[J]. 岩土力学, 2011, 32(3): 709-714.
LI Ying, GONG Xiao-nan, ZHANG Xue-chan. Experimental research on effect of applied voltage on one-dimensional Electroosmotic drainage[J]. Rock and Soil Mechanics, 2011, 32(3): 709-714.
[11] 庄艳峰, 王钊. 电渗固结中的界面电阻问题[J]. 岩土力学, 2004, 25(1): 117-120.
ZHUANG Yan-feng, WANG Zhao. Study on interface electric resistance of electro-osmotic consolidation[J]. Rock and Soil Mechanics, 2004, 25(1): 117-120.
[12] 胡黎明, 洪何清, 吴令伟. 高岭土的电渗试验[J]. 清华大学学报, 2010, 50(9): 1353-1356.
HU Li-ming, HONG He-qing, WU Ling-wei. Electro-osmotic tests on kaolin clay[J]. Journal of Tsinghua University, 2010, 50(9): 1353-1356. |
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
|
Shared |
|
|
|
|
|
Discussed |
|
|
|
|